LGLei Gao

Lei Gao

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Lei Gao has a total of 10 co-authors. Here are the top co-authors by number of shared publications:

  • Ancheng Xue

    State Key Laboratory of Alternate Electrical Power System with Renewable Energy Sources, North China Electric Power University, Beijing, China

    1 shared publication
  • Baoluo Li

    Department of Electrical Engineering, Northeast Electric Power University, Jilin 132012, China

    1 shared publication
  • Jiahuan Zhang

    State Key Laboratory of Alternate Electrical Power System with Renewable Energy Source, North China Electric Power University, Beijing, China

    1 shared publication
  • Jiehao Cui

    State Key Laboratory of Alternate Electrical Power System with Renewable Energy Source, North China Electric Power University, Beijing, China

    1 shared publication
  • Lei Yue

    China Electric Power Research Institute, Haidian District, Beijing 100192, China

    1 shared publication
  • Nan Li

    Key Laboratory of Modern Power System Simulation and Control & Renewable Energy Technology, Ministry of Education, Northeast Electric Power University, Jilin 132012, China

    1 shared publication

Latest Publications

  • Open Access

    A New Quantitative Analysis Method for Overvoltage in Sending End Electric Power System With UHVDC

    by Ancheng Xue, Lei Yue, Jiahuan Zhang, Jiehao Cui, Zhiqiang Li, Yecheng Li, Lei Gao, Weifang Lin, Xiaoyu Ren

    With the development of renewable electric power generation and ultra-high voltage direct current (UHVDC) transmission, the transient overvoltage in the sending end electric power system with UHVDC occurs, but it is lack of quantitative transient voltage assessment index (TVAI) to assess the overvoltage. To deal with the above problems, this paper proposes a new quantitative transient voltage assessment index considering overvoltage and voltage dip in the sending end electric power system with UHVDC, and applies it to analyze different influencing factors of overvoltage and determine the dynamic reactive power compensation capacity. In detail, first, according to the principle of the transient voltage assessment index considering voltage dip and the overvoltage assessment index for the distribution network, a new transient voltage assessment index considering transient overvoltage in the sending end electric power system with UHVDC is proposed with the approximated step function. Then, based on the requirements of the system with UHVDC, the parameters of the proposed transient voltage assessment index are determined. Furthermore, with the absolute and relative sensitivity, the impact of the parameters of voltage dependent current order limiter and current control amplifier on the transient overvoltage is analyzed and compared quantitatively. Finally, the impact of reactive power compensation equipment, such as synchronous condenser, static var compensator, and static var generator, on the transient overvoltage of the system with UHVDC is compared quantitatively, and the reactive compensation capacity needed to maintain transient voltage security and stability is estimated. The two applications show the effectiveness and advantages of the proposed index in the sending end electric power system with UHVDC.


  • Open Access

    Transient Stability Assessment of Power System Based on XGBoost and Factorization Machine

    by Nan Li, Baoluo Li, Lei Gao

    As the deployment of wide-area measurement systems (WAMS) expands, data-driven methods are playing an increasingly important role in transient stability assessment (TSA). However, if the measured data is disturbed by noise or the topological structure of the power system changes, the performance of the model based on data-mining would decline so that it could not meet the needs of realworld scenarios. In this paper, we develop a TSA methodology based on extreme gradient boosting (XGBoost) and factorization machine (FM). Utilizing XGBoost to complete automatically the feature construction and transform the power flow into a sparse matrix. The influence of noise can be reduce due to the sparsity of the new feature set. On this basis, FM algorithm, which has advantage in processing the large sparse matrix, is introduced into the model to complete fault classification. Furthermore, the feature crossing function of FM further mines the interactive information of the spatio-temporal features. For changed topology scenarios, we propose a extended-training set scheme. Adding some pivotal data of topology changes to the training set improves the robustness of the model. Compared with existing studies, the proposed assessment model based on XGBoost-FM not only has the better generalization performance in the case of noise interference or changed topology, but also has the least time consumption and complexity.