JWJun Wu

Jun Wu

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Jun Wu has a total of 63 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Stability of unruptured intracranial aneurysms in the anterior circulation: nomogram models for risk assessment

    by Qingyuan Liu, Xinyi Leng, Junhua Yang, Yi Yang, Pengjun Jiang, Maogui Li, Shaohua Mo, Shuzhe Yang, Jun Wu, Hongwei He, et al.

    OBJECTIVE The probable stability of the lesion is critical in guiding treatment decisions in unruptured intracranial aneurysms (IAs). The authors aimed to develop multidimensional predictive models for the stability of unruptured IAs. METHODS Patients with unruptured IAs in the anterior circulation were prospectively enrolled and regularly followed up. Clinical data were collected, IA morphological features were assessed, and adjacent hemodynamic features were quantified with patient-specific computational fluid dynamics modeling. Based on multivariate logistic regression analyses, nomograms incorporating these factors were developed in a primary cohort (patients enrolled between January 2017 and February 2018) to predict aneurysm rupture or growth within 2 years. The predictive accuracies of the nomograms were compared with the population, hypertension, age, size, earlier rupture, and site (PHASES) and earlier subarachnoid hemorrhage, location, age, population, size, and shape (ELAPSS) scores and validated in the validation cohort (patients enrolled between March and October 2018). RESULTS Among 231 patients with 272 unruptured IAs in the primary cohort, hypertension, aneurysm location, irregular shape, size ratio, normalized wall shear stress average, and relative resident time were independently related to the 2-year stability of unruptured IAs. The nomogram including clinical, morphological, and hemodynamic features (C+M+H nomogram) had the highest predictive accuracy (c-statistic 0.94), followed by the nomogram including clinical and morphological features (C+M nomogram; c-statistic 0.89), PHASES score (c-statistic 0.68), and ELAPSS score (c-statistic 0.58). Similarly, the C+M+H nomogram had the highest predictive accuracy (c-statistic 0.94) in the validation cohort (85 patients with 97 unruptured IAs). CONCLUSIONS Hemodynamics have predictive values for 2-year stability of unruptured IAs treated conservatively. Multidimensional nomograms have significantly higher predictive accuracies than conventional risk prediction scores.


  • Open Access

    Time-Dependent Changes of Automated 3D Breast Ultrasound-Visible Mesh Implants in Patients

    by Minqin Xia, Jun Wu, Guangqian Yan, Quanwei Cai, Qiang Wang, Zhaomin Zhang

    The shrinkage and deformation of the mesh can be the causes of hernia recurrence and other related complications. Accurate visualization of the mesh and its position would greatly aid in assessing mesh shrinkage, evaluating the risk of hernia recurrence, and setting the preoperative plan for repair. The purpose of this study is to noninvasively describe and quantify the shrinkage, movement, and centroid position of lightweight mesh implants using Automated 3D breast ultrasound (ABUS) through in vivo and vitro studies. In vitro study, ABUS can visualize spatial morphological changes in meshes, which solves the problem of difficult imaging detection of lightweight mesh. The vitro study showed that the maximum deviation between the quantification based on ABUS and the actual mesh size was 3.5%. In vivo study, ABUS not only allows for imaging conventional lightweight meshes but also for assessing time-dependent changes in lightweight mesh implants. The average shrinkage from day 5 to day 90 after surgery was 20.2%, while the average deviation in centroid position was 0.23cm in the vivo study. The problem of postoperative evaluation of lightweight mesh imaging can be effectively addressed by time-dependent assessing and analysis of mesh implants in patients.

  • Open Access

    Does the Fixation Device Affect the Fixation Strength of the Tack in Laparoscopic Incisional Hernia Repair?

    by Zhaomin Zhang, Jun Wu, Guangqian Yan, Quanwei Cai, Qiang Wang, Minqin Xia

    Background: In laparoscopic ventral hernia repair (LVHR), the fixation strength of the tack plays a crucial role, but there is a lack of clarity in terms of the role of the fixation devices on the tack. Our purpose was to investigate whether fixation devices affect the fixation strength of tacks. Further, we compare four different fixation devices, including the comparison of firing model, the comparison of shaft design, and the comparison of mechanical properties. Methods: The porcine abdominal wall was used as the experimental material to test the immediate fixation strength of four different fixation devices and 26 tests were performed on each fixation device. During the experiments, the mechanical performance indicators such as fixation strength, fluency, and accuracy of each fixation device were recorded and evaluated. Results: The fixation strengths of the Securestrap™ (ST), ReliaTack™ (RT), AbsorbaTack™ (AT), and SorbaFix™ (SF) were 20.65±4.73N, 10.34±1.62N, 14.70±2.51N, and 12.07±1.94N respectively. The ST device had the best fixation strength (RT, p<0.001; AT, p=0.003; SF, p<0.001). When the fixation device is not used (8.21±1.33N, p<0.001), the fixation strength of the ST device is significantly lower than that when the fixation device is used (20.65±4.73N). In the study of firing mode, compared with the fixation strength of both devices, AT and SF, ST device had significantly greater fixation strength (p=0.003, p<0.001 for AT and SF, respectively). The fixation strength of the non-articulated devices AT and SF was significantly higher than that of the articulated device RT (p=0.002, p=0.016 for AT and SF respectively). The differences were statistically significant. Conclusion: The fixation device allows the tack to exhibit better fixation strength in laparoscopic surgery. Further, we found that the ejection of firing mode achieves better fixation strength. In contrast, for articulated devices, the fixation strength was lower for articulated devices than for non-articulated devices, which may be because the articulated shaft was not ergonomic and hindered the transfer of force.

  • Open Access

    Three-Dimensional Reconstruction and Hemodynamic Analysis of Varicose Veins in Lower Extremities Based on ABUS Image

    by Quanwei Cai, Jun Wu, Rong Wang, Qiang Wang, Zhaomin Zhang, Minqin Xia

    Varicose veins in the lower extremities are enlarged and tortuous veins in the lower extremities and are a common surgical condition, affecting people over a wide age range. Venous tortuosity caused by varicose veins in lower extremities would alter the local wall shear stress (WSS) and may become a risk factor for venous thrombosis. In this study, a realistic model of lower limb veins was reconstructed based on denoised and enhanced ABUS images. Mimics Research 21.0 and Geomagic Wrap 2017 were used to perform a 3D reconstruction of the Preprocessed images. The time-averaged WSS (TAWSS), the oscillatory shear index (OSI), the transverse WSS (transWSS), and the relative residence time (RRT) of the reconstructed 3D model were investigated in Ansys Fluent 2021R1 (Ansys Inc.) using computational fluid dynamics methods(CFD). We relate the centerline radius (CLR) of the morphological parameters to the above four parameters. From the results, it is clear that CLR has a great impact on the distributions of the WSS-derived parameters. In regions with smaller CLR, low TAWSS, and high OSI abnormal regions appear in the inner wall of the curved segment. It is also evident in the RRT plots that flow disturbances are seen in small CLR region. Compared with OSI and TAWSS, transWSS is more sensitive to abnormal regions. TransWSS has basically the same distribution as RRT distribution. The results showed that regions accompanied by small CLR would lead to the formation of abnormal MASS regions at the bend sections and provide these regions with favorable conditions for the onset and/or progression of venous thrombosis. It could help advance the use and promotion of hemodynamics in the clinical setting through this analysis process. Due to the limitations of ultrasound technology, in some cases the ultrasound image may not directly reveal the lesion, but the presence and location of the lesion can be determined by haemodynamics. The diagnostic method proposed in this paper has great potential in the diagnosis of varicose veins in the lower limbs. It can help the practitioner to better understand the patient's condition.

  • Open Access

    Automatic Abdominal Hernia Mesh Detection Based on YOLOM

    by Siqi Chen, Jinli Xu, Jinhua Yu, Jun Wu, Guohui Zhou

    As a new 3-D ultrasound imaging method, an automated breast ultrasound (ABUS) has been widely used in breast abnormality examinations. Because of its excellent 3D visualization, ABUS is also well suited to the detection of an abdominal wall hernia mesh. Due to the inherent low signal-to-noise ratio of ultrasound imaging and the large amount of data generated during ABUS scanning, mesh detection based on subjective observation is extremely time-consuming and prone to missed detection. Therefore, we proposed a novel abdominal hernia wall mesh detection method based on the you only look once version 3 (YOLOv3) method named the YOLOv3 for mesh (YOLOM) method to detect abdominal wall hernia mesh to speed up the ABUS reading process. To make a YOLOM method with a good detection efficiency, we utilized a lightweight cross stage partial attention network (CSPA-Net) as the backbone and applied a feature enhancement network (FEP-Net) to boost the mesh detection accuracy. An improved loss function with completed intersection-over-union (CIoU) and the Swish activation function were also employed to optimize the proposed YOLOM method. We designed ablation study to verify the validity of the proposed method. The average mesh detection precision reached 98.36%, which was 12.51% and 2.35% higher than that of the YOLOv3 and you only look once version 4 (YOLOv4) methods, respectively. The experimental results and comparisons demonstrated that the proposed YOLOM detector is efficient for abdominal wall hernia mesh detection.


  • Open Access

    The role of monitoring platelet function perioperatively and platelet transfusion for operated spontaneous intracerebral hemorrhage patients with long-term oral antiplatelet therapy

    by Kaiwen Wang, Qingyuan Liu, Jun Wu, Yong Cao, Shuo Wang

    Introduction and importance: Spontaneous intracerebral hemorrhage (SICH) with long-term oral antiplatelet therapy (LOAPT) is known as a dilemma in balancing the risk of postoperative rebleeding and ischemic events because of confused coagulation function. We herein describe a report of perioperative management of spontaneous intracerebral hemorrhage patient on long-term oral antiplatelet therapy. Case presentation: A 42-year-old male patient on long-term oral antiplatelet therapy presented with coma, and he was diagnosed with spontaneous intracerebral hemorrhage. Considering the patient's clinical condition, despite the thromboelastography suggested that the inhibition of platelet function was high preoperatively, an emergency craniectomy were underwent. After platelet transfusion during surgery and taking control of the clotting and platelet function postoperatively, the patient was stable without rebleeding and new ischemic events in perioperative period and recovered satisfactorily. Clinical discussion: Rare studies have provided evidence for managing operated spontaneous intracerebral hemorrhage patients on long-term oral antiplatelet therapy, and whether platelet transfusion is recommended was controversial. In this case, we presented monitoring and taking control of clotting and platelet function postoperatively would help in preventing rebleeding and ischemic events in such patients; moreover, platelet transfusion may quickly and safely reverse platelet dysfunction for emergency surgery. This case was the first to report platelet function and coagulation function management in spontaneous intracerebral hemorrhage patients with long-term oral antiplatelet therapy. Conclusion: Monitoring and maintaining coagulation and platelet function perioperatively are essential to balance the risk of postoperative rebleeding and ischemic events. Highlights:


  • Open Access

    Pore texture analysis in automated 3D breast ultrasound images for implanted lightweight hernia mesh identification: a preliminary study

    by Jiting Yang, Haiyan Li, Jun Wu, Liang Sun, Dan Xu, Yuanyuan Wang, Yufeng Zhang, Yue Chen, Lin Chen

    Background: Precise visualization of meshes and their position would greatly aid in mesh shrinkage evaluation, hernia recurrence risk assessment, and the preoperative planning of salvage repair. Lightweight (LW) meshes are able to preserve abdominal wall compliance by generating less post-implantation fibrosis and rigidity. However, conventional 3D imaging techniques such as computed tomography (CT) and magnetic resonance imaging (MRI) cannot visualize the LW meshes. Patients sometimes have to undergo a second-look operation for visualizing the mesh implants. The goal of this work is to investigate the potential advantages of Automated 3D breast ultrasound (ABUS) pore texture analysis for implanted LW hernia mesh identification. Methods: In vitro, the appearances of four different flat meshes in both ABUS and 2D hand-held ultrasound (HHUS) images were evaluated and compared. In vivo, pore texture patterns of 87 hernia regions were analyzed both in ABUS images and their corresponding HHUS images. Results: In vitro studies, the imaging results of ABUS for implanted LW meshes are much more visualized and effective in comparison to HHUS. In vivo, the inter-class distance of 40 texture features was calculated. The texture features of 2D sectional plans (axial and sagittal plane) have no significant contribution to implanted LW mesh identification. Significant contribution was observed in coronal plane. However, since the mesh may have spatial variation such as shrinkage after implantation surgery, the inter-class distance of 3D coronal plane pore texture features are bigger than 2D coronal plane, so the contribution of 3D coronal plane pore texture features are more valuable than 2D coronal plane for implanted LW mesh identification. The use of 3D pore texture features significantly improved the robustness of the identification method in distinguishing between LW mesh and fascia. Conclusions: An innovative new ABUS provides additional pore texture visualization, by separating the LW mesh from the fascia tissues. Therefore, ABUS has the potential to provides more accurate features to characterize pore texture patterns, and ultimately provide more accurate measures for implanted LW mesh identification.


  • Open Access

    MSK1 downregulation is involved in inflammatory responses following subarachnoid hemorrhage in rats

    by Bo Ning, Zhen Li, Lei Ning, Jun Wu, Xin Chen, Pengjun Jiang, Fuxin Lin, Bing Zhao

    Subarachnoid hemorrhage (SAH) is a life‑threatening neurological disease. Recently, inflammatory factors have been confirmed to be responsible for the brain damage associated with SAH. Therefore, studying the post‑SAH inflammatory reaction may clarify the mechanism of SAH. Mitogen and stress‑activated protein kinase 1 (MSK1) causes the phosphorylation of NF‑κB and regulates the activity of pro‑inflammatory transcription factors. The present study aimed to identify the potential role of MSK1 in inflammation and brain damage development following SAH. A cisterna magna blood injection model was established in Sprague‑Dawley rats. Hematoxylin and eosin staining, reverse transcription‑quantitative polymerase chain reaction assays and double immunofluorescence staining were used to analyze the role of MSK1, IL‑1β and TNF‑α in the inflammatory process after SAH. In a model of lipopolysaccharide‑induced astrocyte inflammation, the effect of overexpressing MSK1 overexpression was analyzed by western blot analysis. The results demonstrated that MSK1 expression were negatively correlated with TNF‑α and IL‑1β expression levels, and reached peak levels 2 days after TNF‑α and IL‑1β. The double immunofluorescence staining results showed that the expression of MSK1 was in the same plane of view as TNF‑α and IL‑1β in the brain cortex. Furthermore, the in vitro studies indicated that the overexpression of MSK1 inhibited the expression of TNF‑α and IL‑1β following LPS challenge. These results imply that MSK1 may be involved in the inflammatory reaction following SAH, and may potentially serve as a negative regulator of inflammation.


  • Open Access

    Pore texture analysis in automated 3D breast ultrasound images for implanted lightweight hernia mesh identification: a preliminary study

    by Jiting Yang, Haiyan Li, Jun Wu, Liang Sun, Dan Xu, Yuanyuan Wang, Yufeng Zhang, Yue Chen, Lin Chen

    Background Precise visualization of meshes and their position would greatly aid in mesh shrinkage evaluation, hernia recurrence risk assessment, and the preoperative planning of salvage repair. Lightweight (LW) meshes are able to preserve abdominal wall compliance by generating less post-implant fibrosis and rigidity. However, conventional 3D imaging techniques such as computed tomography (CT) and magnetic resonance imaging (MRI) cannot visualize the LW meshes. Patients sometimes have to undergo a second-look operation for visualizing the mesh implants. The goal of this work is to investigate the potential advantages of Automated 3D breast ultrasound (ABUS) pore texture analysis for implanted LW hernia mesh identification. Methods In vitro, the appearances of four different flat meshes in both ABUS and 2D hand-held ultrasound (HHUS) images were evaluated and compared. In vivo, pore texture patterns of 87 hernia regions were analyzed both in ABUS images and their corresponding HHUS images. Results In vitro studies, the imaging results of ABUS for implanted LW meshes are much more visualized and effective in comparison to HHUS. In vivo, the inter-class distance of 40 texture features was calculated. The texture features of 2D sectional plans (axial and sagittal plane) have no significant contribution to implanted LW mesh identification. Significant contribution was observed in coronal plane. However, since the mesh may have spatial variation such as shrinkage after implant surgery, the inter-class distance of 3D coronal plane pore texture features are bigger than 2D coronal plane, so the contribution of 3D coronal plane pore texture features are more valuable than 2D coronal plane for implanted LW mesh identification. The use of 3D pore texture features significantly improved the robustness of the identification method in distinguishing the LW mesh and fascia. Conclusions An innovative new automated 3D breast ultrasound (ABUS) provides additional pore texture visualization, by separating the LW mesh from the fascia tissues. Therefore, ABUS having the potential to provide more accurate features to characterize pore texture patterns, and ultimately provide more accurate measures for implanted LW mesh identification.

  • Open Access

    Pore texture analysis in automated 3D breast ultrasound images for implanted lightweight hernia mesh identification: a preliminary study

    by Jiting Yang, Haiyan Li, Jun Wu, Liang Sun, Dan Xu, Yuanyuan Wang, Yufeng Zhang, Yue Chen, Lin Chen

    BackgroundPrecise visualization of meshes and their position would greatly aid in mesh shrinkage evaluation, hernia recurrence risk assessment, and the preoperative planning of salvage repair. Lightweight (LW) meshes are able to preserve abdominal wall compliance by generating less post-implant fibrosis and rigidity. However, conventional 3D imaging techniques such as computed tomography (CT) and magnetic resonance imaging (MRI) cannot visualize the LW meshes. Patients sometimes have to undergo a second-look operation for visualizing the mesh implants. The goal of this work is to investigate the potential advantages of Automated 3D breast ultrasound (ABUS) pore texture analysis for implanted LW hernia mesh identification.MethodsIn vitro, the appearances of four different flat meshes in both ABUS and 2D hand-held ultrasound (HHUS) images were evaluated and compared. In vivo, pore texture patterns of 87 hernia regions were analyzed both in ABUS images and their corresponding HHUS images. ResultsIn vitro studies, the imaging results of ABUS for implanted LW meshes are much more visualized and effective in comparison to HHUS. In vivo, the inter-class distance of 40 texture features were calculated. The texture features of 2D sectional plans (axial and sagittal plane) have no significant contribution for implanted LW mesh identification. Significant contribution was observed in coronal plane. However, since the mesh may have spatial variation such as shrinkage after implant surgery, the inter-class distance of 3D coronal plane pore texture features are bigger than 2D coronal plane, so the contribution of 3D coronal plane pore texture features are more valuable than 2D coronal plane for implanted LW mesh identification. The use of 3D pore texture features significantly improved the robustness of the identification method in distinguishing the LW mesh and fascia.ConclusionsAn innovative new automated 3D breast ultrasound (ABUS) provides additional pore texture visualization, by separating the LW mesh from the fascia tissues. Therefore, ABUS having the potential to provide more accurate features to characterize pore texture patterns, and ultimately provide more accurate measures for implanted LW mesh identification.