YZYonghui Zhao

Yonghui Zhao

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Yonghui Zhao has a total of 45 co-authors. Here are the top co-authors by number of shared publications:

  • Sheng Lu

    Department of Orthopedics, The First People’s Hospital of Yunnan Province, The Affiliated Hospital of Kunming University of Science and Technology, Kunming, China

    8 shared publications
  • Jiayu Chen

    The First People’s Hospital of Yunnan Province & The Affiliated Hospital of Kunming University of Science and Technology

    3 shared publications
  • Jinlong Liang

    Department of Orthopedics, 920 Hospital of the Joint Logistic Support Force, Kunming, China

    3 shared publications
  • Yongqing Xu

    Department of Orthopedics, 920th Hospital of the Joint Logistics Support Force of the Chinese People's Liberation Army, 212 Daguan Road, Xishan District, Kunming, China

    3 shared publications
  • Hao-Tian Luo

    Department of Orthopedics, The First People's Hospital of Yunnan Province, The Affiliated Hospital of Kunming University of Science and Technology, The Key Laboratory of Digital Orthopedics of Yunnan Province, No. 157 Jinbi Road, Kunming, China

    2 shared publications
  • Haotian Luo

    Department of Orthopedics, First People's Hospital of Yunnan Province, The Affiliated Hospital of Kunming University of Science and Technology, Key Laboratory of Digital Orthopedics of Yunnan Province, 157 Jinbi Road, Xishan District, Kunming, China

    2 shared publications

Latest Publications

  • Open Access

    Perioperative Complications of Oblique Lateral Interbody Fusion With Unilateral Pedicle Screw Fixation in a Single Lateral Position: A Retrospective Case Series

    by Yonghui Zhao, Weicheng Lin, Qiunan Lyu, Qiyang Wang, Jiayu Chen, Weichao Li, Hui Zhong, Jie Liu, Sheng Lu

    Study Design: Retrospective case series. Objectives: To analyze the perioperative complications of oblique lateral interbody fusion (OLIF) combined with unilateral pedicle screw fixation performed in a single lateral position. Methods: Clinical data of 258 consecutive patients with lumbar degenerative diseases undergoing OLIF-UPS fixation in a single lateral position from July 2019 to June 2025 were collected. Both single- and multi-segment fusions were included. Demographic, intraoperative and perioperative data were extracted for statistical analysis. Results: Among the 258 patients, the overall perioperative complication rate was 17.1%. Neurological deficits (6.2%) and pedicle screw insertion-related complications (5.4%) were the most common. Other complications included endplate injury (3.5%), cage malposition (2.7%), poor incision healing (1.9%), anterior longitudinal ligament injury (1.6%), vascular injury (1.6%), cage subsidence (1.2%), intestinal obstruction (1.2%), and peritoneal injury (0.4%). The complication rate was higher in the Multi-level fusion group than in the single-level group (21.9% vs. 15.5%, P=0.237). The incidences of neurological deficits (7.8% vs. 5.7%, P=0.538) and screw-related complications (7.8% vs. 4.6%, P=0.331) were also higher in the Multi-level group; however, none of these differences reached statistical significance. Conclusions: The overall perioperative complication rate in this cohort was 17.1%, and the perioperative complications were manageable. Further controlled studies with long-term follow-up are needed to compare its efficiency and safety with alternative fixation protocols and positioning strategies.

  • Open Access

    Oblique lumbar interbody fusion with unilateral pedicle screw fixation in a single lateral position for degenerative lumbar diseases

    by Yonghui Zhao, Weicheng Lin, Yachen Li, Hui Zhong, Jie Liu, Sheng Lu

    This study aimed to evaluate the clinical efficacy of oblique lumbar interbody fusion (OLIF) combined with unilateral pedicle screw fixation (OLIF-UPS) performed in a single lateral position for degenerative lumbar diseases. Clinical data of patients who underwent OLIF-UPS in a single lateral position were collected retrospectively. During the same period, patients who received OLIF combined with bilateral pedicle screw fixation (OLIF-BPS) requiring intraoperative position change were enrolled as the control group. Perioperative parameters, Visual Analogue Scale (VAS) scores, Oswestry Disability Index (ODI) scores, and the modified MacNab criteria were recorded to assess clinical outcomes. Radiographic parameters, including disc height (DH), lumbar lordosis (LL), cage subsidence rate, and interbody fusion rate, were compared between the two groups. The operative time in the OLIF-UPS group was significantly shorter than that in the OLIF-BPS group (p 0.05). Postoperatively, VAS scores for back and leg pain and ODI scores were significantly improved in both groups compared with preoperative values (p -2.5), Grade I or no spondylolisthesis, no segmental instability, and BMI <30 kg/m2, single-position OLIF-UPS achieves short-term outcomes comparable to OLIF-BPS while significantly reducing operative time. Given the relatively short follow-up period, further long-term observation is warranted to verify its long-term clinical efficacy.

  • Open Access

    Biomechanical comparison of oblique lateral interbody fusion with interspinous versus other fixation techniques: A finite element study

    by Zhenggang Li, Yiming Liang, Mingqi Jiang, Yonghui Zhao, Jiayu Chen, Xionggang Yang, Sheng Lu

    Background: Oblique lateral interbody fusion (OLIF) is a minimally invasive technique for treating degenerative lumbar diseases, yet the optimal supplemental fixation strategy remains debated. Interspinous fixation systems (ISFS) offer a less invasive alternative to conventional pedicle screw-based constructs, but their biomechanical performance when combined with OLIF is not well characterized. Methods: A validated finite element model of the L3–S1 lumbar spine was used to simulate OLIF at L4–L5 with 5 fixation configurations: stand-alone, unilateral pedicle screw fixation, bilateral pedicle screws fixation (BPSF), ISFS, and ISFS combined with lateral screw fixation (ISFS + lateral screws fixation [LSF]). Range of motion (ROM) at the fused and adjacent segments, along with von Mises stress distributions on the endplates, interbody cage, and instrumentation, were evaluated under a 500 N compressive preload and 10 N·m pure moments in flexion, extension, lateral bending, and axial rotation. Results: All fixation constructs reduced ROM at the fused-segment compared to the intact model. BPSF and ISFS + LSF provided the greatest stability across all loading directions, with ROM reductions exceeding 80% in most postures. ISFS alone effectively stabilized the segment during flexion-extension, but was less effective under rotational and lateral bending loads. Stand-alone OLIF exhibited the highest cage stresses and the largest residual ROM, indicating increased risk of instability and subsidence. ISFS + LSF distributed stress more evenly across the cage and endplates, comparable to BPSF, while reducing stress concentration on the spinous process base during lateral bending. Adjacent segment ROM and endplate stress remained similar across all models and the intact condition. Conclusion: OLIF combined with interspinous fixation, particularly ISFS + LSF, provides a favorable biomechanical profile by enhancing segmental stability and reducing implant-related stress concentrations, while preserving adjacent segment kinematics. ISFS + LSF may serve as a less invasive alternative to BPSF, offering balanced stability and load sharing. ISFS alone is suitable for flexion-dominant loading environments, whereas BPSF remains the most robust option for multiplanar stability at the cost of increased surgical trauma. These findings support the selective use of interspinous fixation in OLIF based on patient-specific biomechanical demands.


  • Open Access

    Metacarpal Lengthening Using a Mini-Ring Ilizarov Device for Thumb Reconstruction

    by Yueliang Zhu, Yongqing Xu, Shaoquan Pu, Qian Lv, Xingbo Cai, Yonghui Zhao


  • Open Access

    A Pain That is Easily Overlooked: Referred Pain Caused by OVCF

    by Wei Lu, Zhaowei Teng, Jiayu Chen, Rongmao Shi, Tiannan Zou, Ming Gao, Weichao Li, Zhi Peng, Long Wang, Yonghui Zhao, et al.

    Purpose: The objective of this study was to analyze the clinical characteristics and the therapeutic effects of treatment at our spinal center in OVCF patients associated with referred pain. The underlying goals were to deepen the understanding of referred pain caused by OVCFs, improve the currently low early diagnosis rate of OVCFs, and improve the effectiveness of treatment. Methods: The patients who had referred pain from OVCFs and met the inclusion criteria were retrospectively analyzed. All patients were treated with percutaneous kyphoplasty (PKP). Visual analog scale (VAS) scores and Oswestry Disability Index (ODI) were used to evaluate the therapeutic effect at different time points. Results: There were 11 males (19.6%) and 45 females (80.4%). Their corresponding mean bone mineral density (BMD) value was − 3.3 ± 0.4. The regression coefficient of BMD in the linear regression equation was − 4.51 (P< 0.001). According to the classification system for referred pain in OVCFs, there were 27 cases of type A (48.2%), 12 cases of type B (21.2%), 8 cases of type C (14.3%), 3 cases of type D (5.4%), and 6 cases of type E (10.7%). All patients were followed up for at least 6 months, and both VAS scores and ODI were found to be significantly better postoperatively than preoperatively (P< 0.001). There was no significant difference in VAS scores and ODI between different types preoperatively or 6 months postoperatively (P > 0.05). Within each type, there were significant differences in VAS scores and ODI between the pre- and postoperative timepoints (P < 0.05). Conclusion: Attention should be paid to referred pain in OVCF patients, which is not uncommon in clinical practice. Our summary of the characteristics of referred pain caused by OVCFs can improve the early diagnosis rate of OVCFs patients and provide a reference for their prognosis after PKP.


  • Open Access

    Treatment of inferior pole fracture of the patella with tension-free external immobilization

    by Shaoquan Pu, Yanling Chen, Jinlong Liang, Yongqing Xu, Yonghui Zhao

    Background: Inferior pole fracture of the patella (IPFP) has small and comminuted fracture blocks that are hard to immobilize, and early mobilization may lead to loss of fracture reduction and immobilization failure. Therefore, a difficulty of treatment is to achieve rigid immobilization with early functional exercise. Here, a new treatment method of tension-free external immobilization is put forward. Methods: The clinical data of 11 IPFP patients treated with tension-free external immobilization from May 2016 to June 2019 were retrospectively analyzed. There were six males and five females aged 39.0 ± 12.8 years (range 18–53 years). IPFP was caused by traffic accidents in five cases and falls in six cases. All cases had unilateral closed injuries, including four in the left knee and seven in the right knee. The preoperative range of motion of the knee was 22.0 ± 7.5° (10–30°). The time from injury to operation was 4.5 ± 1.3 d (3–7 d). The operation-related indices were recorded, and the function of the affected knee was assessed by the Böstman score. Results: All operations were successful. The operation time was 56.4 ± 8.4 mi (45–70 min), the intraoperative blood loss was 54.1 ± 14.6 mL (40–80 mL), and the length of hospital stay was 7.5 ± 1.9 d (5–11 d). The mean follow-up time was 20.4 ± 7.6 months (12–36 months), the duration of fracture healing was 8.9 ± 1.5 weeks (7–12 weeks), and the removal time of the external immobilization device was 10.4 ± 0.9 weeks (9–12 weeks). At the last follow-up, the range of motion had no significant difference between the affected knee (129.7 ± 3.3°, range 125–135°) and the unaffected knee (130.8 ± 3.8°, range 126–137°) (t = 0.718, p < 0.05). The Böstman score of the knee was 29.2 ± 1.0 points (27–30 points), including 10 excellent cases (90.9%) and one good case (9.1%). Conclusion: Tension-free external immobilization is a feasible treatment for IPFP. It can help with early functional exercise and achieve a satisfactory clinical effect.


  • Open Access

    Feasibility of cortical bone trajectory screws for bridging fixation in revision surgery for lumbar adjacent segment degeneration

    by Long Wang, Yong-Hui Zhao, Xing-Bo Cai, Jin-Long Liang, Hao-Tian Luo, Yu-Long Ma, Yong-Qing Xu, Sheng Lu

    Background: To investigate the feasibility of using cortical bone trajectory (CBT) screws for bridging fixation in revision surgery for lumbar adjacent segment degeneration and to provide a reference for clinical practice. Methods: Computed tomography scans of the lumbar spines of 36 patients in our hospital were used. Sixteen males and 20 females with an average age of 65.5 ± 10.5 years (range: 46 to 83 years) were included. Three-dimensional reconstruction was performed using computer software. Screws with appropriate sizes were selected for the L1 to L5 vertebral segments, and traditional pedicle screws were placed using the standard method. After completing screw placement, simulated placement of CBT screws was performed separately. No overlap occurred between the two screws in the process of CBT screw placement, and the placement point and direction were adjusted until screw placement completion. After all screw placement simulations were complete, according to the contact area of the cortical bone of the screw trajectory and the screw puncture position and distance through the trajectory, the screw placement results were categorized as excellent, good, general, and failure. Excellent and good ratings were considered successful, while a general rating was regarded as acceptable. Then, the success rate and acceptable rate of each segment of the lumbar spine were calculated. Results: Three hundred and sixty screw placement simulations were performed in lumbar pedicles, and 72 CBT screws were implanted in each vertebral body of the lumbar spine. The success rates in the L1 to L5 segments were 73.6%, 80.6%, 83.3%, 88.9%, and 77.8%, respectively, and the acceptable rates were 91.7%, 97.2%, 97.2%, 100%, and 91.7%, respectively. The overall success rate and acceptable rate of CBT screw placement in the lumbar spine were 80.8% and 95.6%, respectively. Conclusion: CBT screws are feasible for bridging fixation in lumbar adjacent segment degeneration revision surgery, and the accuracy of screw placement in different lumbar vertebrae varies.


  • Open Access

    Accuracy of S2 Alar-Iliac Screw Placement Under the Guidance of a 3D-Printed Surgical Guide Template

    by Yonghui Zhao, Haotian Luo, Yulong Ma, Jinlong Liang, Gonghai Han, Yongqing Xu, Sheng Lu


  • Open Access

    Anatomical study of the ideal cortical bone trajectory in the lumbar spine

    by Yong-Hui Zhao, Yu-Long Ma, Long Wang, Jin-Long Liang, Hao-Tian Luo, Yong-Qing Xu, Sheng Lu

    Background: To explore the ideal trajectory of lumbar cortical bone trajectory screws and provide the optimal placement scheme in clinical applications. Methods: Lumbar computed tomography (CT) data of 40 patients in our hospital were selected, and the cortical vertebral bone contour model was reconstructed in three dimensions (3D). Depending on the different regions of the screw through the entrance and exit of the pedicle, 9 trajectories were obtained through combinational design: T-Aa, T-Ab, T-Ac, T-Ba, T-Bb, T-Bc, T-Ca, T-Cb, and T-Cc. Cortical bone trajectory (CBT) screws with appropriate diameters were selected to simulate screw placement and measure the parameters corresponding to each trajectory (screw path diameter, screw trajectory length, cephalad angle, and lateral angle), and then determine the optimal screw according to the screw parameters and screw safety. Then, 23 patients in our hospital were selected, and the navigation template was designed based on the ideal trajectory before operation, CBT screws were placed during the operation to further verify the safety and feasibility of the ideal trajectory. Results: T-Bc and T-Bb are the ideal screw trajectories for L1–L2 and L3–L5, respectively. The screw placement point is located at the intersection of the inner 1/3 vertical line of the superior facet joint and the bottom 1/3 horizontal line of the outer crest of the vertebral lamina (i.e., 2–4 mm inward at the bottom 1/3 of the outer crest of the vertebral lamina). CBT screws were successfully placed based on the ideal screw trajectory in clinical practice. During the operation or the follow-up period, there were no adverse events. Conclusion: CBT screw placement based on the ideal screw trajectory is a safe and reliable method for achieving effective fixation and satisfactory postoperative effects.


  • Open Access

    Design of Custom-made Navigational Template of Femoral Head and Pilot Research in Total Hip Resurfacing Arthroplasty

    by Jinlong Liang, Yonghui Zhao, Xinjian Gao, Xuewei Fang, Yongqing Xu, Sheng Lu

    Background To develop a novel custom-made navigational template for accurate prosthesis implantation in total hip resurfacing arthroplasty (THRA) by computer-aided technology. Methods The template was produced based on data preoperatively acquired with computed tomography (CT) scan. The position of the drill guide was chosen as the anatomical axis of the femoral neck which was defined by the ligature between the center of the femoral head and another point on the centerline of proximal femoral neck. And the final direction of the drill guide was confirmed by a small valgus angle. The surface of the template was constructed as the inverse of the femoral neck surface. Then each template was formed from acrylate resin by using rapid prototyping (RP) technique. Finally, the template was tested in 18 cadavers scheduled for THRA and postoperative medical imaging was used to evaluate the accuracy and validity of the template. Results The template had a near-prefect fit with the femoral neck surface. There were no guide failures. Postoperative evaluation revealed that the Kirschner wires pass through the center of the femoral head, have a relative valgus angle to the central axis of the femoral neck and have no obvious varus-valgus angles or anterior/posterior inclination angles. So, the Kirschner wires achieved the expected implant requirement. Conclusion This study shows a novel way of guiding the prosthesis implantation accurately in THRA. The template is an excellent medium for preoperative planning and intraoperative technique, and embodies the development tendency of Computer Assisted Surgery.