H. Scott Norville
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
H. Scott Norville has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
- Stephen Michael Morse
Assistant Professor, Dept. of Civil and Environmental Engineering, Michigan Technological Univ., Houghton, MI 49931. ORCID:
11 shared publications - James G. Soules
Graduate Student, Dept. of Civil, Environmental, and Construction Engineering, Texas Tech Univ., Lubbock, TX 79409. ORCID:
4 shared publications - Kayla Natividad
Texas Tech University
3 shared publications - Matt Bergers
Research and Development, Viracon
2 shared publications Stephen M. Morse
Assistant Professor, Dept. of Civil and Environmental Engineering, Michigan Technological Univ., Houghton, MI 49931
2 shared publications- Bolaji Afolabi
Graduate Student, Dept. of Civil, Environmental, and Construction Engineering, Texas Tech Univ., Lubbock, TX 79409
1 shared publication
Latest Publications
- 1 March 2023
- Published by American Society of Civil Engineers (ASCE) in Journal of Architectural Engineering
- Vol. 29 (1) , 04023002
Effects of Fixed Edge Conditions on the Load Resistance of Single Glass Lites
The load resistance (LR) of glass lites is determined in the United States by use of standards based on a probabilistic model of glass breakage. These standards generally restrict design to rectangular glass lites continuously supported along one, two, three, or four sides. In addition, these standards treat single glass lites as simply supported flat rectangular plates. Historically, rigid window frames supported single glass lites holding them in place with neoprene or similar gasket material. This attachment method approximated simply supported edges that rotate about an axis parallel to the simply supported edges, deform in the plane of the glass lite, and do not deflect out-of-plane. Advances in structural silicone make it possible to produce rectangular single flat glass lites with edge fixity somewhere between that of simply supported edges and fully fixed edges. The authors applied the glass failure prediction model (GFPM) to a nonlinear finite-element model developed previously by the authors to determine the probability of breakage for selected single glass lite geometries with fully fixed edges under uniform lateral loads. The paper presents comparisons between results of analyses of lites with fixed edges with analyses of lites with simply supported edges. The comparisons indicate that not all single glass lite geometries benefit from fully fixing edges, but the benefits of doing so appear to increase as lite aspect ratio (AR) increases. The comparisons bracket benefits that can accrue from the partial fixity provided by structural silicone supports. The actual degree of fixity provided by structural silicone can only be determined experimentally, which lies outside the scope of this paper.
- 1 March 2023
- Published by American Society of Civil Engineers (ASCE) in Journal of Architectural Engineering
- Vol. 29 (1) , 04023002
Effects of Fixed Edge Conditions on the Load Resistance of Single Glass Lites
The load resistance (LR) of glass lites is determined in the United States by use of standards based on a probabilistic model of glass breakage. These standards generally restrict design to rectangular glass lites continuously supported along one, two, three, or four sides. In addition, these standards treat single glass lites as simply supported flat rectangular plates. Historically, rigid window frames supported single glass lites holding them in place with neoprene or similar gasket material. This attachment method approximated simply supported edges that rotate about an axis parallel to the simply supported edges, deform in the plane of the glass lite, and do not deflect out-of-plane. Advances in structural silicone make it possible to produce rectangular single flat glass lites with edge fixity somewhere between that of simply supported edges and fully fixed edges. The authors applied the glass failure prediction model (GFPM) to a nonlinear finite-element model developed previously by the authors to determine the probability of breakage for selected single glass lite geometries with fully fixed edges under uniform lateral loads. The paper presents comparisons between results of analyses of lites with fixed edges with analyses of lites with simply supported edges. The comparisons indicate that not all single glass lite geometries benefit from fully fixing edges, but the benefits of doing so appear to increase as lite aspect ratio (AR) increases. The comparisons bracket benefits that can accrue from the partial fixity provided by structural silicone supports. The actual degree of fixity provided by structural silicone can only be determined experimentally, which lies outside the scope of this paper.
- 1 June 2021
- Published by American Society of Civil Engineers (ASCE) in Journal of Architectural Engineering
- Vol. 27 (2) , 04021001
Application of Glass Failure Prediction Model to Bent Glass Using Finite-Element Modeling
Designers of architectural glass in the United States rely on model building codes and standards for definitions of load resistance (LR) and other factors pertinent to design. Unfortunately, US model building codes and standards currently address only flat glass. These US model building codes and standards provide no generally accepted methodology to facilitate the determination of LT for bent glass. Because architects frequently use bent glass in buildings, a well-defined procedure for determining its LR is needed. The primary analysis tools available to engineers today are based on the finite-element method and can be applied to a wide range of different glass lite geometries. The authors developed a nonlinear finite-element model and applied the glass failure prediction model (GFPM) to the nonlinear finite-element model output to determine the probability of breakage for the specified bent glass lite geometry and the selected load combinations. The results of their analyses compare favorably to the stresses obtained from a strain gauged full-scale bent glass lite test specimen. The authors also compared the LR of the bent glass lite to the LR of a flat glass lite with the same rectangular dimensions of the bent glass lite to demonstrate the strength increase of bent glass constructions over flat glass constructions for the single geometry studied.
- 1 June 2021
- Published by American Society of Civil Engineers (ASCE) in Journal of Architectural Engineering
- Vol. 27 (2) , 04021001
Application of Glass Failure Prediction Model to Bent Glass Using Finite-Element Modeling
Designers of architectural glass in the United States rely on model building codes and standards for definitions of load resistance (LR) and other factors pertinent to design. Unfortunately, US model building codes and standards currently address only flat glass. These US model building codes and standards provide no generally accepted methodology to facilitate the determination of LT for bent glass. Because architects frequently use bent glass in buildings, a well-defined procedure for determining its LR is needed. The primary analysis tools available to engineers today are based on the finite-element method and can be applied to a wide range of different glass lite geometries. The authors developed a nonlinear finite-element model and applied the glass failure prediction model (GFPM) to the nonlinear finite-element model output to determine the probability of breakage for the specified bent glass lite geometry and the selected load combinations. The results of their analyses compare favorably to the stresses obtained from a strain gauged full-scale bent glass lite test specimen. The authors also compared the LR of the bent glass lite to the LR of a flat glass lite with the same rectangular dimensions of the bent glass lite to demonstrate the strength increase of bent glass constructions over flat glass constructions for the single geometry studied.
- 1 April 2021
- Published by Elsevier in Journal of Wind Engineering and Industrial Aerodynamics
- Vol. 211, 104554
Hail impact testing: Velocity effects of distance to target specimen
- 1 April 2021
- Published by Elsevier in Journal of Wind Engineering and Industrial Aerodynamics
- Vol. 211, 104554
Hail impact testing: Velocity effects of distance to target specimen
- 1 December 2020
- Published by American Society of Civil Engineers (ASCE) in Journal of Architectural Engineering
- Vol. 26 (4) , 06020001
Insulating Glass Unit Quick Selection Guide
The structural design of sealed insulating glass units for wind loads involves complex structural mechanics procedures that address load sharing between two glass lites that vary in thickness, dimensions, and heat treatments. In exhaustive studies of windows in mid- and high-rise buildings, it has been shown that any one of six commonly used window glass lites [6, 8, 10 mm (1/4, 5/16, 3/8 in.), heat-strengthened and fully tempered], acting alone, can represent the minimum load resistance of dual-lite, sealed insulating glass units that contain this lite when paired with any one of the six listed lites. Further, the minimum load resistance of each of these six lites can be related to building height by employing wind load design of current standards. An innovative technique permits selection of dual-lite insulating glass unit constructions for mid- and high-rise buildings in the Inland Zone and a Hurricane Zone that meet wind load provisions of building codes based upon building height alone, without calculations.
- 1 December 2020
- Published by American Society of Civil Engineers (ASCE) in Journal of Architectural Engineering
- Vol. 26 (4) , 06020001
Insulating Glass Unit Quick Selection Guide
The structural design of sealed insulating glass units for wind loads involves complex structural mechanics procedures that address load sharing between two glass lites that vary in thickness, dimensions, and heat treatments. In exhaustive studies of windows in mid- and high-rise buildings, it has been shown that any one of six commonly used window glass lites [6, 8, 10 mm (1/4, 5/16, 3/8 in.), heat-strengthened and fully tempered], acting alone, can represent the minimum load resistance of dual-lite, sealed insulating glass units that contain this lite when paired with any one of the six listed lites. Further, the minimum load resistance of each of these six lites can be related to building height by employing wind load design of current standards. An innovative technique permits selection of dual-lite insulating glass unit constructions for mid- and high-rise buildings in the Inland Zone and a Hurricane Zone that meet wind load provisions of building codes based upon building height alone, without calculations.
- 1 December 2020
- Published by American Society of Civil Engineers (ASCE) in Journal of Architectural Engineering
- Vol. 26 (4) , 04020037
Application of the Glass Failure Prediction Model to Flat Odd-Shaped Glass Using Finite-Element Modeling
Model building codes and standards in the United States find their bases in a probabilistic model of glass load resistance (LR). In general, architectural flat glass design predicated on these model building codes and standards is restricted to rectangular glass lites continuously supported along one, two, three, or four sides. When a design professional wishes to use glass with an odd shape (i.e., a nonrectangular shape), design procedures in the model building codes and standards regress to a maximum stress approach. A maximum stress approach to design represents a much different philosophy than does the probabilistic approach. When compared to the probabilistic approach, designs based upon a value of maximum allowable stress may result in much less efficient design. Therefore, the need exists for a design approach for odd-shaped glass lites that has a probabilistic basis for glass load resistance. The primary analysis tools available to engineers today are based on the finite-element method and can be applied to a wide range of different glass lite geometries. The authors developed a nonlinear finite-element model and applied the glass failure prediction model (GFPM) to the nonlinear finite-element model output to determine probability of breakage for combinations of selected flat odd-shaped glass lite geometries and loads. The authors compared the LR of the odd-shaped glass lites to the LR of flat glass lites with the LR of rectangular glass lites having the smallest dimensions so that they would encompass the odd-shaped lites. The authors also compared the maximum principal stresses determined for the flat odd-shaped glass lites (loaded with a pressure equal to the LR of the flat odd-shaped glass lites) from the nonlinear finite-element model to recommended values of maximum allowable stress from model building codes and standards.
- 1 December 2020
- Published by American Society of Civil Engineers (ASCE) in Journal of Architectural Engineering
- Vol. 26 (4) , 04020037
Application of the Glass Failure Prediction Model to Flat Odd-Shaped Glass Using Finite-Element Modeling
Model building codes and standards in the United States find their bases in a probabilistic model of glass load resistance (LR). In general, architectural flat glass design predicated on these model building codes and standards is restricted to rectangular glass lites continuously supported along one, two, three, or four sides. When a design professional wishes to use glass with an odd shape (i.e., a nonrectangular shape), design procedures in the model building codes and standards regress to a maximum stress approach. A maximum stress approach to design represents a much different philosophy than does the probabilistic approach. When compared to the probabilistic approach, designs based upon a value of maximum allowable stress may result in much less efficient design. Therefore, the need exists for a design approach for odd-shaped glass lites that has a probabilistic basis for glass load resistance. The primary analysis tools available to engineers today are based on the finite-element method and can be applied to a wide range of different glass lite geometries. The authors developed a nonlinear finite-element model and applied the glass failure prediction model (GFPM) to the nonlinear finite-element model output to determine probability of breakage for combinations of selected flat odd-shaped glass lite geometries and loads. The authors compared the LR of the odd-shaped glass lites to the LR of flat glass lites with the LR of rectangular glass lites having the smallest dimensions so that they would encompass the odd-shaped lites. The authors also compared the maximum principal stresses determined for the flat odd-shaped glass lites (loaded with a pressure equal to the LR of the flat odd-shaped glass lites) from the nonlinear finite-element model to recommended values of maximum allowable stress from model building codes and standards.
- 1 June 2020
- Published by American Society of Civil Engineers (ASCE) in Journal of Architectural Engineering
- Vol. 26 (2)
Effects of Silicone Coatings on Heat Strengthened and Fully Tempered Glass
This study investigated the effects of inorganic silicone coatings on the load resistance of heat treated glass beams. The authors performed destructive load tests on 192 heat treated glass beams divided into 6 samples. Three samples consisted of heat strengthened glass and three samples consisted of fully tempered glass. For each glass type, one sample consisted of clear glass, i.e., no coating, and the other two samples had different types of silicone coatings. The authors analyzed the failure data from the samples. The data indicate that the silicone coatings did not adversely impact the load resistance of the heat treated glass, and in the heat strengthened samples, the silicone coatings apparently increased the load resistance of the glass beams.
- 1 June 2020
- Published by American Society of Civil Engineers (ASCE) in Journal of Architectural Engineering
- Vol. 26 (2)
Effects of Silicone Coatings on Heat Strengthened and Fully Tempered Glass
This study investigated the effects of inorganic silicone coatings on the load resistance of heat treated glass beams. The authors performed destructive load tests on 192 heat treated glass beams divided into 6 samples. Three samples consisted of heat strengthened glass and three samples consisted of fully tempered glass. For each glass type, one sample consisted of clear glass, i.e., no coating, and the other two samples had different types of silicone coatings. The authors analyzed the failure data from the samples. The data indicate that the silicone coatings did not adversely impact the load resistance of the heat treated glass, and in the heat strengthened samples, the silicone coatings apparently increased the load resistance of the glass beams.
- 1 June 2020
- Published by American Society of Civil Engineers (ASCE) in Journal of Architectural Engineering
- Vol. 26 (2)
Application of the Glass Failure Prediction Model to Flat Glass Using Finite-Element Modeling
Architectural glazing designers in the United States and many other parts of the world use prescriptive methods to determine the load resistance (LR) of glazing and glazing constructions in buildings based on a probabilistic theory of glass strength. This theory is known as the glass failure prediction model (GFPM). The GFPM relates the probability of breakage to surface stress magnitude induced by lateral uniform loads acting on the glass as well as the duration of stress. Glass design charts in US model building codes and standards use a nonlinear finite difference model developed during the early 1980s as the basis to determine surface stresses induced by lateral loads. The primary analysis tools available to engineers today are based on the finite-element method and not on the finite difference method. The authors developed a nonlinear finite-element model and applied the GFPM to the nonlinear finite-element model output to determine the probability of breakage for selected glass lite geometry and load combinations. The results of their analyses compare favorably with values in model building codes and standards. This model will facilitate architectural glazing designers when they must design glazing for fenestrations that charts in model building codes and standards currently do not address.
- 1 June 2020
- Published by American Society of Civil Engineers (ASCE) in Journal of Architectural Engineering
- Vol. 26 (2)
Application of the Glass Failure Prediction Model to Flat Glass Using Finite-Element Modeling
Architectural glazing designers in the United States and many other parts of the world use prescriptive methods to determine the load resistance (LR) of glazing and glazing constructions in buildings based on a probabilistic theory of glass strength. This theory is known as the glass failure prediction model (GFPM). The GFPM relates the probability of breakage to surface stress magnitude induced by lateral uniform loads acting on the glass as well as the duration of stress. Glass design charts in US model building codes and standards use a nonlinear finite difference model developed during the early 1980s as the basis to determine surface stresses induced by lateral loads. The primary analysis tools available to engineers today are based on the finite-element method and not on the finite difference method. The authors developed a nonlinear finite-element model and applied the GFPM to the nonlinear finite-element model output to determine the probability of breakage for selected glass lite geometry and load combinations. The results of their analyses compare favorably with values in model building codes and standards. This model will facilitate architectural glazing designers when they must design glazing for fenestrations that charts in model building codes and standards currently do not address.
- 1 March 2018
- Published by American Society of Civil Engineers (ASCE) in Journal of Architectural Engineering
- Vol. 24 (1)
Experimental Investigation of Load Sharing in Insulating Glass Units
The method for determining load resistance of insulating glass in ASTM standards uses a load-share factor equation based only on glass-lite thicknesses to estimate the load carried by each lite. This paper presents an experimental investigation of load sharing of double- and triple-glazed insulating glass units. The major factors varied in the investigation include unit rectangular dimensions, glass-lite thicknesses, and initial airspace volumes. Pressure versus deflection curves are presented for select insulating glass unit configurations. A second testing procedure explores the measured change in pressure within the sealed airspaces while simultaneously measuring applied pressure and associated deflections. Changes in pressures in the sealed airspaces are directly compared to the ASTM standard load-share factors. Figures in this paper show the load-sharing trends of various similarly loaded insulating glass units, and the results presented in this paper suggest many of the neglected factors significantly influence load sharing in insulating glass units.
- 1 March 2018
- Published by American Society of Civil Engineers (ASCE) in Journal of Architectural Engineering
- Vol. 24 (1)
Experimental Investigation of Load Sharing in Insulating Glass Units
The method for determining load resistance of insulating glass in ASTM standards uses a load-share factor equation based only on glass-lite thicknesses to estimate the load carried by each lite. This paper presents an experimental investigation of load sharing of double- and triple-glazed insulating glass units. The major factors varied in the investigation include unit rectangular dimensions, glass-lite thicknesses, and initial airspace volumes. Pressure versus deflection curves are presented for select insulating glass unit configurations. A second testing procedure explores the measured change in pressure within the sealed airspaces while simultaneously measuring applied pressure and associated deflections. Changes in pressures in the sealed airspaces are directly compared to the ASTM standard load-share factors. Figures in this paper show the load-sharing trends of various similarly loaded insulating glass units, and the results presented in this paper suggest many of the neglected factors significantly influence load sharing in insulating glass units.
- 27 November 2017
- Published by Springer Nature in Glass Structures & Engineering
- Vol. 3 (1) , 119
Correction to: Full scale tests of heat strengthened glass with ceramic frit
- 27 November 2017
- Published by Springer Nature in Glass Structures & Engineering
- Vol. 3 (1) , 119
Correction to: Full scale tests of heat strengthened glass with ceramic frit
- 1 September 2017
- Published by American Society of Civil Engineers (ASCE) in Journal of Architectural Engineering
- Vol. 23 (3)
Tests of Heat-Treated Glass with Full-Coverage Ceramic Frit
The observation that spandrel glass with ceramic frit has experienced thermal breakage in several buildings has called into question the ability of heat-treated (HT) glass with ceramic frit to resist fracture induced by lateral loads. The authors note that the use of ceramic frit is not restricted to interior lites of spandrel insulating glass. Currently, glass design standards in the United States do not specifically address any impact ceramic frit might have on the load resistance (LR) of HT glass, while European standards impose a reduction on allowable stress in HT glass with ceramic frit. This article presents the results from the first phase of a research program aimed at determining the reduction in LR that ensues from the application of a ceramic frit to HT glass. The results of this research indicate that ceramic frit significantly weakens HT glass to which it is applied.
- 1 September 2017
- Published by American Society of Civil Engineers (ASCE) in Journal of Architectural Engineering
- Vol. 23 (3)
Tests of Heat-Treated Glass with Full-Coverage Ceramic Frit
The observation that spandrel glass with ceramic frit has experienced thermal breakage in several buildings has called into question the ability of heat-treated (HT) glass with ceramic frit to resist fracture induced by lateral loads. The authors note that the use of ceramic frit is not restricted to interior lites of spandrel insulating glass. Currently, glass design standards in the United States do not specifically address any impact ceramic frit might have on the load resistance (LR) of HT glass, while European standards impose a reduction on allowable stress in HT glass with ceramic frit. This article presents the results from the first phase of a research program aimed at determining the reduction in LR that ensues from the application of a ceramic frit to HT glass. The results of this research indicate that ceramic frit significantly weakens HT glass to which it is applied.