Mauro Caravati
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Mauro Caravati has a total of 27 co-authors. Here are the top co-authors by number of shared publications:
A. Prini
CNR STIIMA, Milano 20133, Italy
1 shared publicationA. Zardoni
AZ Pneumatica S.r.l., Misinto (MB) 20826, Italy
1 shared publication- Alberto Devoto
Dipartmento di Fisica Universitá di Cagliari and INFN Sezione di Cagliari Cagliari Italy
1 shared publication - Alessandro Razeto
INFN, Laboratori Nazionali del Gran Sasso, Assergi 67100
1 shared publication - Andrea Ianni
Department of Physics Princeton University 08544 Princeton NJ USA
1 shared publication - Arthur B. McDonald
Queen’s University, Kingston, Canada
1 shared publication
Latest Publications
- Open Access
Mechanical Ventilator Milano (MVM): A Novel Mechanical Ventilator Designed for Mass Scale Production in Response to the COVID-19 Pandemics
We present here the design of the Mechanical Ventilator Milano (MVM), a novel mechanical ventilator designed for mass scale production in response to the COVID-19 pandemics, to compensate for the dramatic shortage of such ventilators in many countries. This ventilator is an electro-mechanical equivalent of the old, reliable Manley Ventilator. Our design is optimized to permit large sale production in short time and at a limited cost, relying on off-the-shelf components, readily available worldwide from hardware suppliers. Operation of the MVM requires only a source of compressed oxygen (or compressed medical air) and electrical power. The MVM control and monitoring unit can be connected and networked via WiFi so that no additional electrical connections are necessary other than the connection to the electrical power. At this stage the MVM is not a certified medical device. Construction of the first prototypes is starting with a team of engineers, scientists and computing experts. The purpose of this paper is to disseminate the conceptual design of the MVM broadly and to solicit feed-back from the scientific and medical community to speed the process of review, improvement and possible implementation.
Open AccessMechanical Ventilator Milano (MVM): A Novel Mechanical Ventilator Designed for Mass Scale Production in Response to the COVID-19 Pandemics
We present here the design of the Mechanical Ventilator Milano (MVM), a novel mechanical ventilator designed for mass scale production in response to the COVID-19 pandemics, to compensate for the dramatic shortage of such ventilators in many countries. This ventilator is an electro-mechanical equivalent of the old, reliable Manley Ventilator. Our design is optimized to permit large sale production in short time and at a limited cost, relying on off-the-shelf components, readily available worldwide from hardware suppliers. Operation of the MVM requires only a source of compressed oxygen (or compressed medical air) and electrical power. The MVM control and monitoring unit can be connected and networked via WiFi so that no additional electrical connections are necessary other than the connection to the electrical power. At this stage the MVM is not a certified medical device. Construction of the first prototypes is starting with a team of engineers, scientists and computing experts. The purpose of this paper is to disseminate the conceptual design of the MVM broadly and to solicit feed-back from the scientific and medical community to speed the process of review, improvement and possible implementation.
- Open Access
Noncommutative QED and the Lifetimes of Ortho and Para Positronium
We examine the implications of including corrections associated with the noncommutative extension of quantum electrodynamics - NCQED - to the decays of the ortho and para positronium (\Trip and \Sing) ground states. In NCQED, the well known charge conjugation argument restricting \Trip decays to an odd number of photons and \Sing decays to an even number of photons no longer obtains. Instead, the dominant two photon decay mode of \Sing is accompanied by a three photon mode. The dominant three photon decay mode of \Trip receives a NCQED correction, but there is no corresponding two photon decay mode in the weak binding limit. These corrections to the $P_s$ three photon decay mode have a different energy distribution, but their effect is too small to explain any discrepancy between the observed and calculated values of the \Trip lifetime.Open AccessNoncommutative QED and the Lifetimes of Ortho and Para Positronium
We examine the implications of including corrections associated with the noncommutative extension of quantum electrodynamics - NCQED - to the decays of the ortho and para positronium (\Trip and \Sing) ground states. In NCQED, the well known charge conjugation argument restricting \Trip decays to an odd number of photons and \Sing decays to an even number of photons no longer obtains. Instead, the dominant two photon decay mode of \Sing is accompanied by a three photon mode. The dominant three photon decay mode of \Trip receives a NCQED correction, but there is no corresponding two photon decay mode in the weak binding limit. These corrections to the $P_s$ three photon decay mode have a different energy distribution, but their effect is too small to explain any discrepancy between the observed and calculated values of the \Trip lifetime.