YMYuko Miki

Yuko Miki

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Yuko Miki has a total of 32 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Long-Term Heart Failure Stabilization and Autonomic Trends After Bilateral Cardiac Sympathetic Denervation

    by Yuko Miki, Shingo Yoshimura, Takehito Sasaki, Kenichi Kaseno, Kohki Nakamura, Nogiku Niwamae, Mitsuhiro Kamiyoshihara, Shigeto Naito

  • Open Access

    Characteristics of radiofrequency lesions in patients with symptomatic periesophageal vagal nerve injury after pulmonary vein isolation

    by Shingo Yoshimura, Yutaka Take, Kenichi Kaseno, Koji Goto, Yuji Matsuo, Hideyuki Aoki, Takehito Sasaki, Yuko Miki, Kohki Nakamura, Shigeto Naito

    Background: Periesophageal vagal nerve injury (PNI) is an unpredictable and serious complication of atrial fibrillation (AF) ablation. We aimed to identify the factors associated with symptomatic PNI.Methods: This study included 1391 patients who underwent ablation index‐guided pulmonary vein isolation (PVI) using the CARTO system. The target ablation index was set at 550, except for the left atrial (LA) posterior wall near the esophagus, where radiofrequency (RF) power and duration were limited. Ten patients (0.72%) were diagnosed with symptomatic PNI. We randomly selected 40 patients without PNI (1:4 ratio) matched based on age, sex, body mass index, LA diameter, type of AF, and esophageal location. We measured the shortest distance from the RF lesions to the esophagus (LED) and classified the RF lesions according to the LED into four groups: 0–5, 5–10, 10–15, and 15–20 mm. We conducted a comparative analysis of classified RF lesions between patients with PNI (n = 10) and those without (n = 40).Results: The contact force at LED 0–5 mm was significantly higher in patients with PNI than in those without (14.6 ± 1.7 vs. 12.0 ± 2.9 g; p = .01). Multivariate logistic analysis revealed that the independent factor for PNI was contact force at an LED of 0–5 mm (odds ratio: 1.506; 95% confidence interval: 1.053–2.153; p = .025).Conclusions: The symptomatic PNI was significantly associated with a higher contact force near the esophagus. Strategies for regulating contact force near the esophagus may aid in the prevention of PNI.


  • Open Access

    Local impedance measurements during contact force‐guided cavotricuspid isthmus ablation for predicting an effective radiofrequency ablation

    by Takehito Sasaki, Kohki Nakamura, Kentaro Minami, Yutaka Take, Yosuke Nakatani, Yuko Miki, Koji Goto, Kenichi Kaseno, Eiji Yamashita, Keiko Koyama, et al.

    Background An ablation catheter capable of contact force (CF) and local impedance (LI) monitoring (IntellaNav StablePoint, Boston Scientific) has been recently launched. We evaluated the relationship between the CF and LI values during radiofrequency catheter ablation (RFCA) along the cavotricuspid isthmus (CTI). Methods Fifty consecutive subjects who underwent a CTI-RFCA using IntellaNav StablePoint catheters were retrospectively studied. The initial CF and LI at the start of the RF applications and mean CF and minimum LI during the RF applications were measured. The absolute and percentage LI drops were calculated as the difference between the initial and minimum LIs and 100 × absolute LI drop/initial LI, respectively. Results We analyzed 602 first-pass RF applications. A weak correlation was observed between the initial CF and LI (r = 0.13) and between the mean CF and LI drops (r = 0.22). The initial LI and absolute and percentage LI drops were greater at effective ablation sites than ineffective ablation sites (median, 151 vs. 138 Ω, 22 vs. 14 Ω, and 14.4% vs. 9.9%; p < .001), but the initial and mean CF did not differ. At optimal cutoffs of 21 Ω and 10.8% for the absolute and percentage LI drops according to the receiver-operating characteristic analysis, the sensitivity, and specificity for predicting an effective ablation were 57.4% and 88.9% and 80.0%, and 61.1%, respectively. Conclusions The effective sites during the CF-guided CTI-RFCA had greater initial LI and LI drops than the ineffective sites. Absolute and percentage LI drops of 21 Ω and 10.8% may be appropriate targets for an effective ablation.


  • Symptomatic and asymptomatic intracerebral hemorrhages detected by magnetic resonance imaging after catheter ablation of atrial fibrillation

    by Kohki Nakamura, Takehito Sasaki, Kentaro Minami, Yutaka Take, Koki Kimura, Yumiko Haraguchi, Wataru Sasaki, Shohei Kishi, Shingo Yoshimura, Yosuke Nakatani, et al.

    Purpose Symptomatic intracerebral hemorrhages (ICHs) are a rare complication after atrial fibrillation (AF) catheter ablation, while the incidence of asymptomatic ICHs detected by magnetic resonance (MR) imaging remains unclear. This study aimed to investigate the incidence, characteristics, and predictors of new-onset ICHs on MR imaging after AF ablation. Methods We retrospectively studied 1257 consecutive AF ablation procedures in 1201 patients who underwent MR imaging on the day after the procedure. Repeat MR imaging within 3 months post-ablation was available in 352 procedures. Results Old ICHs on the initial MR imaging were observed in 28 procedures (2.2%). Post-ablation new ICHs were observed in 14 procedures (4.0%), including one symptomatic (0.3%) and 13 (3.7%) asymptomatic ICHs. One patient had a new ICH on the initial MR imaging, while the remaining 13 had such on the repeat MR imaging. A univariate analysis revealed that a previous ischemic stroke or transient ischemic attack (TIA) and the CHA2DS2-VASc score were positive predictors of new ICHs (odds ratios, 5.502 and 1.435; P = 0.004 and 0.044). The lesion diameter did not significantly differ between the old and new ICHs (median, 6.1 mm vs. 8.0 mm, P = 0.281), while the predominant location differed (lobar areas, 22.6% vs. 53.3%; cerebellum, 22.6% vs. 20.0%; others, 54.8% vs. 26.7%; P = 0.026). Conclusions A few asymptomatic ICHs may occur after AF ablation. Most of the post-ablation new ICHs occurred a few days or later after the procedure. A previous ischemic stroke/TIA and the CHA2DS2-VASc score may be risk factors for post-ablation ICHs.


  • Hypertrophic Cardiomyopathy Complicated by Cardiac Sarcoidosis Diagnosed by Both the Morphological Abnormalities and the Time Course of the Disease

    by Yuko Miki, Kohki Nakamura, Takahito Sasaki, Koji Goto, Yutaka Take, Shigeto Naito

    The definite diagnosis of cardiac sarcoidosis (CS) can be difficult because it mimics other cardiomyopathies and morphological abnormalities during its time course. Distinguishing CS isolated cardiac sarcoidosis from other cardiomyopathies is very important for the introduction of immunosuppressive therapy. In this study, we report a patient who had initially been diagnosed with hypertrophic obstructive cardiomyopathy (HOCM). The patient developed complete atrioventricular block (CAVB) and morphological abnormalities, which led to his primary diagnosis being re-conducted. Moreover, we made a definite diagnose of isolated CS (ICS) based on the guideline for the diagnosis and treatment using 18F-fluorodeoxyglucose positron emission tomography/computed tomography (18F-FDG-PET/CT)1) and performed tailor-made treatment including immunosuppressive therapy.


  • Open Access

    Optimal local impedance drops for an effective radiofrequency ablation during cavo‐tricuspid isthmus ablation

    by Takehito Sasaki, Kohki Nakamura, Mitsuho Inoue, Kentaro Minami, Yuko Miki, Koji Goto, Yutaka Take, Kenichi Kaseno, Eiji Yamashita, Keiko Koyama, et al.

    Purpose: A novel ablation catheter capable of local impedance (LI) monitoring (IntellaNav MiFi OI, Boston Scientific) has been recently introduced to clinical practice. We aimed to determine the optimal LI drops for an effective radiofrequency ablation during cavo‐tricuspid isthmus (CTI) ablation.Methods: This retrospective observational study enrolled 50 consecutive patients (68 ± 9 years; 34 males) who underwent a CTI ablation using the IntellaNav MiFi OI catheter, guided by Rhythmia. The LI at the start of radiofrequency applications (initial LI) and minimum LI during radiofrequency applications were evaluated. The absolute and percentage LI drops were defined as the difference between the initial and minimum LIs and 100× absolute LI drop/initial LI, respectively.Results: A total of 518 radiofrequency applications were analyzed. The absolute and percentage LI drops were significantly greater at effective ablation sites than ineffective sites (median, 15 ohms vs 8 ohms, P < .0001; median, 14.7% vs 8.3%, P < .0001). A receiver‐operating characteristic analysis demonstrated that at optimal cutoffs of 12 ohms and 11.6% for the absolute and percentage LI drops, the sensitivity and specificity for predicting the effectiveness of the ablation were 66.5% and 88.2%, and 65.1% and 88.2%, respectively. Finally, bidirectional conduction block along the CTI was achieved in all patients.Conclusions: During the LI‐guided CTI ablation, the effective RF ablation sites exhibited significantly greater absolute and percentage LI drops than the ineffective RF ablation sites. Absolute and percentage LI drops of 12 ohms and 11.6% may be suitable targets for effective ablation.


  • Open Access

    The effect of bilateral cardiac sympathetic denervation for refractory ventricular tachycardia in ischemic cardiomyopathy

    by Yuko Miki, Takehito Sasaki, Yoshinori Okazaki, Mitsuho Inoue, Katsura Niijima, Hiroyuki Motoda, Yutaka Take, Kentaro Minami, Nogiku Niwamae, Mitsuhiro Kamiyoshihara, et al.

    Recent studies have shown that cardiac sympathetic denervation (CSD) is effective in the treatment of refractory ventricular tachyarrhythmia in patients with structural heart disease. This case report aimed to highlight the effect of bilateral CSD in suppressing treatment‐resistant ventricular tachycardia in patients with ischemic cardiomyopathy.