Caroline Bonnet
Caroline Bonnet has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- François Lapicque
CNRS, LRGP, University of Lorraine, Nancy, France
5 shared publications - Stéphane Raël
Universit de Lorraine, GREEN, Nancy, France
4 shared publications Anantrao Vijay Shirsath
2 shared publications- Anantrao Vijay Shirsath1 shared publication
Divyesh Arora
1 shared publicationFadi Sharif
1 shared publication
Latest Publications
- 21 July 2025
- Published by Elsevier in Journal of Power Sources
- Vol. 654
Physical-based reduced model of lithium-ion batteries dedicated to observer design for embedded applications
- 21 July 2025
- Published by Elsevier in Journal of Power Sources
- Vol. 654
Physical-based reduced model of lithium-ion batteries dedicated to observer design for embedded applications
- 25 March 2022
- Published by Elsevier in Journal of Power Sources
- Vol. 531
Analysis of gas transport phenomena in a polymer electrolyte fuel cell by electrochemical pressure impedance spectroscopy
- 25 March 2022
- Published by Elsevier in Journal of Power Sources
- Vol. 531
Analysis of gas transport phenomena in a polymer electrolyte fuel cell by electrochemical pressure impedance spectroscopy
- Open Access
- 1 March 2022
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 169 (3) , 034503
Electrochemical Pressure Impedance Spectroscopy for Polymer Electrolyte Membrane Fuel Cells: A Combined Modeling and Experimental Analysis
Electrochemical pressure impedance spectroscopy (EPIS) has recently been developed as a potential diagnosis tool for polymer electrolyte membrane fuel cells (PEMFC). It is based on analyzing the frequency response of the cell voltage with respect to an excitation of the gas-phase pressure. We present here a combined modeling and experimental study of EPIS. A pseudo-two-dimensional PEMFC model was parameterized to a 100 cm2 laboratory cell installed in its test bench, and used to reproduce steady-state cell polarization and electrochemical impedance spectra (EIS). Pressure impedance spectra were obtained both in experiment and simulation by applying a harmonic pressure excitation at the cathode outlet. The model shows good agreement with experimental data for current densities ≤ 0.4 A cm−2. Here it allows a further simulative analysis of observed EPIS features, including the magnitude and shape of spectra. Key findings include a strong influence of the humidifier gas volume on EPIS and a substantial increase in oxygen partial pressure oscillations towards the channel outlet at the resonance frequency. At current densities ≥ 0.8 A cm−2 the experimental EIS and EPIS data cannot be fully reproduced. This deviation might be associated with the formation and transport of liquid water, which is not included in the model.
- 1 March 2022
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 169 (3) , 034503
Open AccessElectrochemical Pressure Impedance Spectroscopy for Polymer Electrolyte Membrane Fuel Cells: A Combined Modeling and Experimental Analysis
Electrochemical pressure impedance spectroscopy (EPIS) has recently been developed as a potential diagnosis tool for polymer electrolyte membrane fuel cells (PEMFC). It is based on analyzing the frequency response of the cell voltage with respect to an excitation of the gas-phase pressure. We present here a combined modeling and experimental study of EPIS. A pseudo-two-dimensional PEMFC model was parameterized to a 100 cm2 laboratory cell installed in its test bench, and used to reproduce steady-state cell polarization and electrochemical impedance spectra (EIS). Pressure impedance spectra were obtained both in experiment and simulation by applying a harmonic pressure excitation at the cathode outlet. The model shows good agreement with experimental data for current densities ≤ 0.4 A cm−2. Here it allows a further simulative analysis of observed EPIS features, including the magnitude and shape of spectra. Key findings include a strong influence of the humidifier gas volume on EPIS and a substantial increase in oxygen partial pressure oscillations towards the channel outlet at the resonance frequency. At current densities ≥ 0.8 A cm−2 the experimental EIS and EPIS data cannot be fully reproduced. This deviation might be associated with the formation and transport of liquid water, which is not included in the model.