Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Jingyi Tang has a total of 64 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Laser-Modulation-Driven X-Ray Pulse Shaping in Regenerative Amplifier Free-Electron Lasers

    by Zhen Zhang, Jingyi Tang, Erik Hemsing, Zhirong Huang

    In this Letter, we present a robust method for generating custom-shaped, coherent hard x-ray pulses in regenerative amplifier free-electron lasers (RAFELs) using laser-induced energy modulation of the electron beam. A temporally shaped optical modulation imprints an optical-wavelength energy pattern on the beam, which interacts with the recirculated seed in the x-ray cavity to generate spectral sidebands. These sidebands lie outside the Bragg reflection bandwidth and are extracted as out-coupled radiation, while the seed is retained for continued amplification, enabling a novel mechanism for both output coupling and pulse shaping. This approach allows deterministic control over the spectral and temporal properties of the emitted x-rays, including multicolor generation, twin-pulse structures, pulse duration tuning, and complex temporal waveforms. Importantly, it does not require modification of the RAFEL cavity or optics and is fully compatible with high-repetition-rate operation, offering a practical pathway to deliver coherent, shaped, and on-demand x-ray pulses for advanced time-resolved and nonlinear x-ray science.


  • Open Access

    Pulse-by-pulse transient thermal deformation in crystal optics under high-repetition-rate FEL

    by Lin Zhang, Jerome Hastings, Zhirong Huang, Jingyi Tang, Diling Zhu

    Time-domain modeling of the thermal deformation of crystal optics can help define acceptable operational ranges across the pulse-energy repetition-rate phase space. In this paper, we have studied the transient thermal deformation of a water-cooled diamond crystal for a cavity-based X-ray free-electron laser (CBXFEL), either an X-ray free-electron laser oscillator (XFELO) or a regenerative amplifier X-ray free-electron laser (RAFEL), by numerical simulations including finite-element analysis and advanced data processing. Pulse-by-pulse transient thermal deformation of a 50 µm-thick diamond crystal has been performed with X-ray pulse repetition rates between 50 kHz and 1 MHz. Results for temperature and thermal deformation have been compared with the results of transient analysis using a continuous wave (CW) power loading. Temperature and thermal deformation results from pulse-by-pulse transient analysis vary with time about the results for the CW case for the same average power. The variation amplitude increases with pulse energy and decreases with repetition rate. When the repetition rate increases to infinity, both temperature and thermal deformation converge to the results for the CW case. Two critical time scales for the operation of crystal optics in a CBXFEL are (1) first-turn time, i.e. the time for the XFEL pulse to complete the first turn around the cavity so that the crystal sees the recirculated XFEL pulse, and (2) period-end time, i.e. the time that the next electron bunch arrives for the amplification, so that the crystal outcouples the amplified FEL power. For the same average power, simulation results show that the crystal thermal deformation seen by the XFEL beam decreases with repetition rate at the first-turn time of a 300 m-long cavity and increases with repetition rate at the period-end time. For the wavefront preservation requirement of the crystal optics, a pulse-energy versus repetition-rate phase space has been established. The upper bounds of the pulse energy at both first-turn and period-end times decreases with repetition rate, especially at the period-end time. The upper bound of the thermal deformation of the crystal at the period-end time for any repetition frequency can be estimated from the CW case. For a water-cooled diamond crystal of dimension 5 mm × 5 mm × 0.05 mm, the time to reach a quasi steady-state is about 50 ms for temperature and 50 µs for thermal deformation


  • Open Access

    A High-Flux Compact X-ray Free-Electron Laser for Next-Generation Chip Metrology Needs

    by James B. Rosenzweig, Gerard Andonian, Ronald Agustsson, Petr M. Anisimov, Aurora Araujo, Fabio Bosco, Martina Carillo, Enrica Chiadroni, Luca Giannessi, Zhirong Huang, et al.

    Recently, considerable work has been directed at the development of an ultracompact X-ray free-electron laser (UCXFEL) based on emerging techniques in high-field cryogenic acceleration, with attendant dramatic improvements in electron beam brightness and state-of-the-art concepts in beam dynamics, magnetic undulators, and X-ray optics. A full conceptual design of a 1 nm (1.24 keV) UCXFEL with a length and cost over an order of magnitude below current X-ray free-electron lasers (XFELs) has resulted from this effort. This instrument has been developed with an emphasis on permitting exploratory scientific research in a wide variety of fields in a university setting. Concurrently, compact FELs are being vigorously developed for use as instruments to enable next-generation chip manufacturing through use as a high-flux, few nm lithography source. This new role suggests consideration of XFELs to urgently address emerging demands in the semiconductor device sector, as identified by recent national need studies, for new radiation sources aimed at chip manufacturing. Indeed, it has been shown that one may use coherent X-rays to perform 10–20 nm class resolution surveys of macroscopic, cm scale structures such as chips, using ptychographic laminography techniques. As the XFEL is a very promising candidate for realizing such methods, we present here an analysis of the issues and likely solutions associated with extending the UCXFEL to harder X-rays (above 7 keV), much higher fluxes, and increased levels of coherence, as well as methods of applying such a source for ptychographic laminography to microelectronic device measurements. We discuss the development path to move the concept to rapid realization of a transformative XFEL-based application, outlining both FEL and metrology system challenges.


  • Open Access

    An Ultra-Compact X-ray Regenerative Amplifier Free-Electron Laser

    by Madison Singleton, James Rosenzweig, Jingyi Tang, Zhirong Huang

    There is a growing interest in designing and building compact X-ray Free Electron Lasers (FELs) for scientific and industry applications. In this paper, we report an X-ray Regenerative Amplifier FEL (XRAFEL) design based on a proposed Ultra Compact X-ray FEL configuration. Our results show that an XRAFEL can dramatically enhance the temporal coherence and increase the spectral brightness of the radiation in the hard X-ray regime without increasing the footprint of the FEL configuration. The proposed compact, fully coherent, and high-flux hard X-ray source holds promise as a valuable candidate for a wide range of high-impact applications in both academia and industry.


  • Open Access

    A high-flux compact X-ray free-electron laser for next-generation chip metrology needs

    by James B. Rosenzweig, Gerard Andonian, Ronald Agustsson, Petr M. Anisimov, Aurora Araujo, Fabio Bosco, Martina Carillo, Enrica Chiadroni, Luca Giannessi, Zhirong Huang, et al.

    Recently, considerable work has been directed at development of a ultra-compact X-ray free-electron laser based on emerging techniques in high field cryogenic acceleration, with attendant dramatic improvements in electron beam brightness, and state-of-the-art concepts in beam dynamics, magnetic undulators, and X-ray optics. A full conceptual design of a 1 nm XFEL with a length and cost over an order of magnitude below current XFELs has resulted from this effort. This instrument has been developed with an emphasis on permitting exploratory scientific research in a wide variety of fields in a university setting. Concurrently, compact FELs are being urgently developed for use as an instrument to enable next generation chip manufacturing through use as a high flux, few-nm lithography source. This new role suggests consideration of XFELs to addressed urgently emerging demands in this sector, as identified by recent national need studies, for new radiation sources aimed at chip manufacturing: a coherent hard X-ray source which enables frontier metrology methods. Indeed, it has been shown that one may use coherent X-rays to perform 10 nm-class resolution surveys of macroscopic, cm-scale structures such as chips, using ptychographic laminography. As the XFEL is a very promising candidate for realizing such methods, we present here an analysis of the issues and likely solutions associated with extending the UCXFEL to harder X-rays (above 7 keV), much higher fluxes and levels of coherence, and methods of applying such a source for ptychographic laminography to micro-electronic device measurements. We discuss the development path to move the concept to rapid realization of a transformative FEL-based application, outlining FEL and metrology system challenges.


  • Open Access

    Active Q-Switched X-Ray Regenerative Amplifier Free-Electron Laser

    by Jingyi Tang, Zhen Zhang, Jenny Morgan, Erik Hemsing, Zhirong Huang

    Despite tremendous progress in x-ray free-electron laser (FEL) science over the last decade, future applications still demand fully coherent, stable x rays that have not been demonstrated in existing x-ray FEL facilities. In this Letter, we describe an active Q-switched x-ray regenerative amplifier FEL scheme to produce fully coherent, high-brightness, hard x rays at a high-repetition rate. By using simple electron-beam phase space manipulation, we show this scheme is flexible in controlling the x-ray cavity quality factor Q and hence the output radiation. We report both theoretical and numerical studies on this scheme with a wide range of accelerator, x-ray cavity, and undulator parameters.


  • Open Access

    Electron beam shaping for actively outcoupling radiation from an x-ray regenerative amplifier free-electron laser

    by Jingyi Tang, Joseph P. Duris, Gabriel Marcus, Agostino Marinelli

    We present a method to actively outcouple radiation from an x-ray regenerative amplifier. The method uses an undulator within a cavity formed by the diamond mirror and is driven by a high repetition rate linac to build up a high power, narrow bandwidth seed within the cavity. Shaping the electron beam via laser heater modulation on a subsequent pass increases the bandwidth of the x-ray free-electron laser pulse beyond the bandwidth of the diamond mirrors, transmitting the radiation from the cavity. A fraction of the power from the shaped pulse is returned to the cavity, reducing the subsequent number of passes needed to rebuild the seed and increasing the duty factor. The cavity seeding may be used to produce short pulses that are significantly more stable than those produced via self-amplified spontaneous emission (SASE) or enhanced SASE.


  • Open Access

    Case of equilibrium beam distribution dependence on storage ring nonlinearity

    by Jingyi Tang, Xiaobiao Huang

    In an electron storage ring, the emittances are determined by the beam energy and the linear lattice; the effects of lattice nonlinearity are usually negligible. In this study, we show a case where the vertical emittance has a strong quadratic dependence on the vertical chromaticity, a form of lattice nonlinearity. In this case, a crab cavity is present in the lattice, which couples the longitudinal and vertical motions of the beam. A theoretic analysis is conducted to derive the emittance dependence on chromaticity, using the normal form approach to decouple the longitudinal and vertical motion. Particle tracking simulations are performed to verify the analytic results and a good agreement is found. The dependence of equilibrium emittances on nonlinear lattice properties as demonstrated in this paper may provide new possibilities for design options and machine control.