Madison Singleton
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Madison Singleton has a total of 128 co-authors. Here are the top co-authors by number of shared publications:
- Adrien Descamps
School of Mathematics and Physics, Queen’s University Belfast, Belfast, UK
3 shared publications - Emma E. McBride
School of Mathematics and Physics, Queen’s University Belfast, Belfast, UK
3 shared publications - James B. Rosenzweig
UCLA
3 shared publications - Jingyi Tang
SLAC National Accelerator Laboratory
3 shared publications - Zhirong Huang
SLAC National Accelerator Laboratory
3 shared publications - Alex Murokh
RadiaBeam Technologies, 1717 Stewart Ave., Santa Monica, CA 90404, USA
2 shared publications
Latest Publications
- 1 November 2026
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 97 (11)
A platform for two-color pump–probe x-ray Thomson scattering using the SPring-8 Angstrom Compact free-electron LAser
We report the first demonstration of x-ray Thomson scattering (XRTS) at the SPring-8 Angstrom Compact free-electron LAser (SACLA) using a compact, multi-diagnostic platform designed for x-ray pump–probe experiments. The setup integrates x-ray diffraction (XRD) and three Highly Annealed Pyrolytic Graphite (HAPG) crystal analyzers setup in a Von Hamos geometry for the simultaneous detection of collective and non-collective x-ray scattering, as well as x-ray fluorescence (XRF) spectroscopy. Using the two-color beam mode at SACLA , we present simultaneous XRTS, XRF, and XRD measurements from copper, aluminum, and nickel foils. These results establish the viability of high-precision XRTS measurements at SACLA and demonstrate a flexible platform for future studies of isochorically heated matter, enabling investigations of non-equilibrium electron thermalization and ultrafast electron dynamics under extreme conditions.
- 1 November 2026
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 97 (11)
A platform for two-color pump–probe x-ray Thomson scattering using the SPring-8 Angstrom Compact free-electron LAser
We report the first demonstration of x-ray Thomson scattering (XRTS) at the SPring-8 Angstrom Compact free-electron LAser (SACLA) using a compact, multi-diagnostic platform designed for x-ray pump–probe experiments. The setup integrates x-ray diffraction (XRD) and three Highly Annealed Pyrolytic Graphite (HAPG) crystal analyzers setup in a Von Hamos geometry for the simultaneous detection of collective and non-collective x-ray scattering, as well as x-ray fluorescence (XRF) spectroscopy. Using the two-color beam mode at SACLA , we present simultaneous XRTS, XRF, and XRD measurements from copper, aluminum, and nickel foils. These results establish the viability of high-precision XRTS measurements at SACLA and demonstrate a flexible platform for future studies of isochorically heated matter, enabling investigations of non-equilibrium electron thermalization and ultrafast electron dynamics under extreme conditions.
- Open Access
- 26 August 2026
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 33 (5) , 1281-1288
Single-shot hard X-ray spectrometer with uniform spatial and spectral response
Knowledge of the shot-to-shot incident spectrum in X-ray free-electron laser (XFEL) experiments is crucial for the analysis and interpretation of experimental data collected from various spectroscopic techniques such as X-ray Thomson scattering, resonant inelastic X-ray scattering and X-ray pump–probe experiments. In this article, we present a novel spectrometer design capable of accurately measuring the incident self-amplified spontaneous emission (SASE) XFEL spectrum on a shot-to-shot basis that is free of spatial and spectral inhomogeneities, such as chirp and central energy jitter that are inherent to XFEL radiation. The setup consists of glassy carbon as a dispersive element, a flat Si (444) analyzer crystal and a 2D pixel detector. Direct comparisons with existing spectral monitors are obtained using a reconstruction method based on frequency-resolved stochastic correlations between the measured incident SASE spectrum and the well characterized collective scattering excitations from aluminium.
- 26 August 2026
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 33 (5) , 1281-1288
Open AccessSingle-shot hard X-ray spectrometer with uniform spatial and spectral response
Knowledge of the shot-to-shot incident spectrum in X-ray free-electron laser (XFEL) experiments is crucial for the analysis and interpretation of experimental data collected from various spectroscopic techniques such as X-ray Thomson scattering, resonant inelastic X-ray scattering and X-ray pump–probe experiments. In this article, we present a novel spectrometer design capable of accurately measuring the incident self-amplified spontaneous emission (SASE) XFEL spectrum on a shot-to-shot basis that is free of spatial and spectral inhomogeneities, such as chirp and central energy jitter that are inherent to XFEL radiation. The setup consists of glassy carbon as a dispersive element, a flat Si (444) analyzer crystal and a 2D pixel detector. Direct comparisons with existing spectral monitors are obtained using a reconstruction method based on frequency-resolved stochastic correlations between the measured incident SASE spectrum and the well characterized collective scattering excitations from aluminium.
- Open Access
- 18 June 2026
- Published by American Physical Society (APS) in Physical Review Letters
- Vol. 136 (24) , 245102
Momentum-Resolved X-Ray Thomson Scattering Benchmark of Electronic-Response Models in Warm Dense Aluminium
The robust diagnosis of conditions generated in warm dense matter experiments remains a persistent challenge. Here, we describe the measurement of shock-compressed aluminium at 50 GPa with angle-resolved femtosecond x-ray Thomson scattering (XRTS) over a wide range of scattering wave vectors at the European X-Ray Free-Electron Laser. The measured plasmon dispersion and line shape show that the standard approach for analyzing XRTS spectra, using uniform-electron-gas models, systematically overestimates the resonance energy by up to 8 eV. We present an approach using methods that agrees within the experimental uncertainty and demonstrates how accounting for shock-induced disorder in shock-compressed systems is critical for their understanding, providing evidence that treatments are required for reliable XRTS inference in warm dense aluminium.
- 18 June 2026
- Published by American Physical Society (APS) in Physical Review Letters
- Vol. 136 (24) , 245102
Open AccessMomentum-Resolved X-Ray Thomson Scattering Benchmark of Electronic-Response Models in Warm Dense Aluminium
The robust diagnosis of conditions generated in warm dense matter experiments remains a persistent challenge. Here, we describe the measurement of shock-compressed aluminium at 50 GPa with angle-resolved femtosecond x-ray Thomson scattering (XRTS) over a wide range of scattering wave vectors at the European X-Ray Free-Electron Laser. The measured plasmon dispersion and line shape show that the standard approach for analyzing XRTS spectra, using uniform-electron-gas models, systematically overestimates the resonance energy by up to 8 eV. We present an approach using methods that agrees within the experimental uncertainty and demonstrates how accounting for shock-induced disorder in shock-compressed systems is critical for their understanding, providing evidence that treatments are required for reliable XRTS inference in warm dense aluminium.
- Open Access
- 1 March 2024
- Published by MDPI AG in Instruments
- Vol. 8 (1) , 19
A High-Flux Compact X-ray Free-Electron Laser for Next-Generation Chip Metrology Needs
Recently, considerable work has been directed at the development of an ultracompact X-ray free-electron laser (UCXFEL) based on emerging techniques in high-field cryogenic acceleration, with attendant dramatic improvements in electron beam brightness and state-of-the-art concepts in beam dynamics, magnetic undulators, and X-ray optics. A full conceptual design of a 1 nm (1.24 keV) UCXFEL with a length and cost over an order of magnitude below current X-ray free-electron lasers (XFELs) has resulted from this effort. This instrument has been developed with an emphasis on permitting exploratory scientific research in a wide variety of fields in a university setting. Concurrently, compact FELs are being vigorously developed for use as instruments to enable next-generation chip manufacturing through use as a high-flux, few nm lithography source. This new role suggests consideration of XFELs to urgently address emerging demands in the semiconductor device sector, as identified by recent national need studies, for new radiation sources aimed at chip manufacturing. Indeed, it has been shown that one may use coherent X-rays to perform 10–20 nm class resolution surveys of macroscopic, cm scale structures such as chips, using ptychographic laminography techniques. As the XFEL is a very promising candidate for realizing such methods, we present here an analysis of the issues and likely solutions associated with extending the UCXFEL to harder X-rays (above 7 keV), much higher fluxes, and increased levels of coherence, as well as methods of applying such a source for ptychographic laminography to microelectronic device measurements. We discuss the development path to move the concept to rapid realization of a transformative XFEL-based application, outlining both FEL and metrology system challenges.
- 1 March 2024
- Published by MDPI AG in Instruments
- Vol. 8 (1) , 19
Open AccessA High-Flux Compact X-ray Free-Electron Laser for Next-Generation Chip Metrology Needs
Recently, considerable work has been directed at the development of an ultracompact X-ray free-electron laser (UCXFEL) based on emerging techniques in high-field cryogenic acceleration, with attendant dramatic improvements in electron beam brightness and state-of-the-art concepts in beam dynamics, magnetic undulators, and X-ray optics. A full conceptual design of a 1 nm (1.24 keV) UCXFEL with a length and cost over an order of magnitude below current X-ray free-electron lasers (XFELs) has resulted from this effort. This instrument has been developed with an emphasis on permitting exploratory scientific research in a wide variety of fields in a university setting. Concurrently, compact FELs are being vigorously developed for use as instruments to enable next-generation chip manufacturing through use as a high-flux, few nm lithography source. This new role suggests consideration of XFELs to urgently address emerging demands in the semiconductor device sector, as identified by recent national need studies, for new radiation sources aimed at chip manufacturing. Indeed, it has been shown that one may use coherent X-rays to perform 10–20 nm class resolution surveys of macroscopic, cm scale structures such as chips, using ptychographic laminography techniques. As the XFEL is a very promising candidate for realizing such methods, we present here an analysis of the issues and likely solutions associated with extending the UCXFEL to harder X-rays (above 7 keV), much higher fluxes, and increased levels of coherence, as well as methods of applying such a source for ptychographic laminography to microelectronic device measurements. We discuss the development path to move the concept to rapid realization of a transformative XFEL-based application, outlining both FEL and metrology system challenges.
- Open Access
- 5 January 2024
- Published by MDPI AG in Instruments
- Vol. 8 (1) , 2
An Ultra-Compact X-ray Regenerative Amplifier Free-Electron Laser
There is a growing interest in designing and building compact X-ray Free Electron Lasers (FELs) for scientific and industry applications. In this paper, we report an X-ray Regenerative Amplifier FEL (XRAFEL) design based on a proposed Ultra Compact X-ray FEL configuration. Our results show that an XRAFEL can dramatically enhance the temporal coherence and increase the spectral brightness of the radiation in the hard X-ray regime without increasing the footprint of the FEL configuration. The proposed compact, fully coherent, and high-flux hard X-ray source holds promise as a valuable candidate for a wide range of high-impact applications in both academia and industry.
- 5 January 2024
- Published by MDPI AG in Instruments
- Vol. 8 (1) , 2
Open AccessAn Ultra-Compact X-ray Regenerative Amplifier Free-Electron Laser
There is a growing interest in designing and building compact X-ray Free Electron Lasers (FELs) for scientific and industry applications. In this paper, we report an X-ray Regenerative Amplifier FEL (XRAFEL) design based on a proposed Ultra Compact X-ray FEL configuration. Our results show that an XRAFEL can dramatically enhance the temporal coherence and increase the spectral brightness of the radiation in the hard X-ray regime without increasing the footprint of the FEL configuration. The proposed compact, fully coherent, and high-flux hard X-ray source holds promise as a valuable candidate for a wide range of high-impact applications in both academia and industry.
- Open Access
- 28 November 2023
- Published by MDPI AG in Preprints.org
A high-flux compact X-ray free-electron laser for next-generation chip metrology needs
Recently, considerable work has been directed at development of a ultra-compact X-ray free-electron laser based on emerging techniques in high field cryogenic acceleration, with attendant dramatic improvements in electron beam brightness, and state-of-the-art concepts in beam dynamics, magnetic undulators, and X-ray optics. A full conceptual design of a 1 nm XFEL with a length and cost over an order of magnitude below current XFELs has resulted from this effort. This instrument has been developed with an emphasis on permitting exploratory scientific research in a wide variety of fields in a university setting. Concurrently, compact FELs are being urgently developed for use as an instrument to enable next generation chip manufacturing through use as a high flux, few-nm lithography source. This new role suggests consideration of XFELs to addressed urgently emerging demands in this sector, as identified by recent national need studies, for new radiation sources aimed at chip manufacturing: a coherent hard X-ray source which enables frontier metrology methods. Indeed, it has been shown that one may use coherent X-rays to perform 10 nm-class resolution surveys of macroscopic, cm-scale structures such as chips, using ptychographic laminography. As the XFEL is a very promising candidate for realizing such methods, we present here an analysis of the issues and likely solutions associated with extending the UCXFEL to harder X-rays (above 7 keV), much higher fluxes and levels of coherence, and methods of applying such a source for ptychographic laminography to micro-electronic device measurements. We discuss the development path to move the concept to rapid realization of a transformative FEL-based application, outlining FEL and metrology system challenges.
- 28 November 2023
- Published by MDPI AG in Preprints.org
Open AccessA high-flux compact X-ray free-electron laser for next-generation chip metrology needs
Recently, considerable work has been directed at development of a ultra-compact X-ray free-electron laser based on emerging techniques in high field cryogenic acceleration, with attendant dramatic improvements in electron beam brightness, and state-of-the-art concepts in beam dynamics, magnetic undulators, and X-ray optics. A full conceptual design of a 1 nm XFEL with a length and cost over an order of magnitude below current XFELs has resulted from this effort. This instrument has been developed with an emphasis on permitting exploratory scientific research in a wide variety of fields in a university setting. Concurrently, compact FELs are being urgently developed for use as an instrument to enable next generation chip manufacturing through use as a high flux, few-nm lithography source. This new role suggests consideration of XFELs to addressed urgently emerging demands in this sector, as identified by recent national need studies, for new radiation sources aimed at chip manufacturing: a coherent hard X-ray source which enables frontier metrology methods. Indeed, it has been shown that one may use coherent X-rays to perform 10 nm-class resolution surveys of macroscopic, cm-scale structures such as chips, using ptychographic laminography. As the XFEL is a very promising candidate for realizing such methods, we present here an analysis of the issues and likely solutions associated with extending the UCXFEL to harder X-rays (above 7 keV), much higher fluxes and levels of coherence, and methods of applying such a source for ptychographic laminography to micro-electronic device measurements. We discuss the development path to move the concept to rapid realization of a transformative FEL-based application, outlining FEL and metrology system challenges.
- 1 July 1994
- Published by IOP Publishing in Plasma Physics and Controlled Fusion
- Vol. 36 (7A) , A111-A116
Characteristics of ohmic H-modes in COMPASS-D
The COMPASS-D tokamak has recently obtained H-mode plasmas in a single-null X-point configuration with no additional heating. Clear H-mode signatures have been observed including reduction in Dalpha light and the unmistakable appearance of ELMs and ELM-free periods. Recycling and gas puff can play crucial roles in achieving and terminating the H-modes. The emergence of distinct ELMs, from the apparently-random fluctuations, of the background Dalpha light, is usually one of progression, taking some 10s of ms rather than a sudden discontinuity. The relatively slow evolution allows for detail examination of important phenomena, such as improvements to confinement and fluid rotation. The H-mode quality improves with density, unless impurity accumulation becomes important. Improvements to the energy and particle confinement are observed and are accompanied by positive increases in the radial electric field at approximately=4 cm inside the last closed flux surface (LCFS). The ohmic powers in discharges with clearly defined H-modes have not been less, so far, than the power obtained from power threshold scalings from larger machines.
- 1 July 1994
- Published by IOP Publishing in Plasma Physics and Controlled Fusion
- Vol. 36 (7A) , A111-A116
Characteristics of ohmic H-modes in COMPASS-D
The COMPASS-D tokamak has recently obtained H-mode plasmas in a single-null X-point configuration with no additional heating. Clear H-mode signatures have been observed including reduction in Dalpha light and the unmistakable appearance of ELMs and ELM-free periods. Recycling and gas puff can play crucial roles in achieving and terminating the H-modes. The emergence of distinct ELMs, from the apparently-random fluctuations, of the background Dalpha light, is usually one of progression, taking some 10s of ms rather than a sudden discontinuity. The relatively slow evolution allows for detail examination of important phenomena, such as improvements to confinement and fluid rotation. The H-mode quality improves with density, unless impurity accumulation becomes important. Improvements to the energy and particle confinement are observed and are accompanied by positive increases in the radial electric field at approximately=4 cm inside the last closed flux surface (LCFS). The ohmic powers in discharges with clearly defined H-modes have not been less, so far, than the power obtained from power threshold scalings from larger machines.