SCSeth C. Cordts

Seth C. Cordts

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Seth C. Cordts has a total of 19 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Combining avidin with CD63 improves basophil activation test accuracy in classifying peanut allergy

    by Nicolas Castaño, Kaiser Chua, Abhinav Kaushik, Sungu Kim, Seth C. Cordts, Ceena D. Nafarzadegan, Grady H. Hofmann, Hana Seastedt, Jackson P. Schuetz, Diane Dunham, et al.

    Background: Conventional basophil activation tests (BATs) measure basophil activation by the increased expression of CD63. Previously, fluorophore‐labeled avidin, a positively‐charged molecule, was found to bind to activated basophils, which tend to expose negatively charged granule constituents during degranulation. This study further compares avidin versus CD63 as basophil activation biomarkers in classifying peanut allergy.Methods: Seventy subjects with either a peanut allergy (N = 47), a food allergy other than peanut (N = 6), or no food allergy (N = 17) were evaluated. We conducted BATs in response to seven peanut extract (PE) concentrations (0.01–10,000 ng/mL) and four control conditions (no stimulant, anti‐IgE, fMLP (N‐formylmethionine‐leucyl‐phenylalanine), and anti‐FcεRI). We measured avidin binding and CD63 expression on basophils with flow cytometry. We evaluated logistic regression and XGBoost models for peanut allergy classification and feature identification.Results: Avidin binding was correlated with CD63 expression. Both markers discriminated between subjects with and without a peanut allergy. Although small by percentage, an avidin+/CD63− cell subset was found in all allergic subjects tested, indicating that the combination of avidin and CD63 could allow a more comprehensive identification of activated basophils. Indeed, we obtained the best classification accuracy (97.8% sensitivity, 96.7% specificity) by combining avidin and CD63 across seven PE doses. Similar accuracy was obtained by combining PE dose of 10,000 ng/mL for avidin and PE doses of 10 and 100 ng/mL for CD63.Conclusions: Avidin and CD63 are reliable BAT activation markers associated with degranulation. Their combination enhances the identification of activated basophils and improves the classification accuracy of peanut allergy.


  • Fabrication of a silicon μDicer for uniform microdissection of tissue samples

    by Seth C. Cordts, Nicolas Castaño, Saisneha Koppaka, Sindy K. Y. Tang

    Generating uniform tissue microfragments is important in many applications, including disease diagnostics, drug screening, spatial-omics, and fundamental wound healing and tissue regeneration studies. Common mechanical dissection methods, such as manual mincing, are imprecise and result in fragments with a broad range in size. This work aims to develop a microscale dicing device, referred to as the “μDicer,” consisting of a hollow array of blades spaced hundreds of micrometers apart. A tissue pushed through this array is diced into many microfragments simultaneously. The focus of this paper is on the fabrication process of the μDicer using a combination of isotropic and anisotropic etching in silicon. A single silicon oxide etch mask is used in a dry silicon etcher for both a tapered etch to form the microblades, and an anisotropic etch to form the through-holes in the hollow blade array. The use of a single mask reduces the mask fabrication time by more than twofold compared with two-mask approaches often used to generate similar etch features. The etch parameters and the design of the etch mask control the blade angles and the edge profiles of the blades. Specifically, the incorporation of “notches” in the two-dimensional mask design generates three-dimensional microserrated features on the blade edges. A custom, open-source etching model is also developed to facilitate the prediction of the etch profiles. Finally, a proof-of-concept application of the μDicer to dissect soft materials and tissues is demonstrated.


  • Open Access

    Microfluidic methods for precision diagnostics in food allergy

    by Nicolas Castaño, Seth C. Cordts, Kari C. Nadeau, Mindy Tsai, Stephen J. Galli, Sindy K. Y. Tang

    Food allergy has reached epidemic proportions and has become a significant source of healthcare burden. Oral food challenge, the gold standard for food allergy assessment, often is not performed because it places the patient at risk of developing anaphylaxis. However, conventional alternative food allergy tests lack a sufficient predictive value. Therefore, there is a critical need for better diagnostic tests that are both accurate and safe. Microfluidic methods have the potential of helping one to address such needs and to personalize the diagnostics. This article first reviews conventional diagnostic approaches used in food allergy. Second, it reviews recent efforts to develop novel biomarkers and in vitro diagnostics. Third, it summarizes the microfluidic methods developed thus far for food allergy diagnosis. The article concludes with a discussion of future opportunities for using microfluidic methods for achieving precision diagnostics in food allergy, including multiplexing the detection of multiple biomarkers, sampling of tissue-resident cytokines and immune cells, and multi-organ-on-a-chip technology.