Hyun-Keun Kwon
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Hyun-Keun Kwon has a total of 27 co-authors. Here are the top co-authors by number of shared publications:
- Gabrielle Davis Vukasin
Mechanical Engineering Department, Stanford University, Stanford, CA 94305 USA
9 shared publications Thomas W. Kenny
Department of Mechanical Engineering and the Department of Electrical Engineering, Stanford University, Stanford, CA, USA
9 shared publications- Nicholas Eric Bousse
Departments of Mechanical Engineering, Stanford University, Stanford, California 94305, USA
4 shared publications - Anne Louise Alter
Stanford University, Stanford, CA, USA
3 shared publications - James Marion Lehto Miller
Departments of Mechanical and Electrical Engineering, Stanford University 3 , Stanford, California 94305, USA
3 shared publications Christopher Patrick Cameron
Stanford University, Stanford, CA, USA
2 shared publications
Latest Publications
- Open Access
- 7 January 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Journal of Microelectromechanical Systems
- Vol. 31 (2) , 204-216
Effects of Remote Boundary Conditions on Clamping Loss in Micromechanical Resonators
Clamping loss in micromechanical resonators can strongly depend on the boundary conditions far away from the actual vibrating structure because the acoustic wavelength greatly exceeds the device dimensions. We demonstrate a scheme for post-fabrication tuning of the clamping loss in flexural-mode and bulk-mode resonators by modifying the boundary conditions of the chip with the frame. The measured quality factor increases by more than an order-of-magnitude for the microcantilevers and more than a factor of three for the bulk-mode resonators when frame contact is minimized via suspension of the chip by wirebonds. We propose a two-degree-of-freedom fluctuation-dissipation model to describe the thermomechanical noise and forced response in the presence of this tunable anchor damping. By studying the thermomechanical displacement spectrum with tunable clamping loss, we show that variable clamping loss tunes the mechanical quality factor, modifying both the resonator transfer function and thermomechanical noise force. We delineate the dependence of the tunable clamping loss mechanism on microcantilever beam length and ambient temperature from 300 K down to 40 K, and observe potential temperature dependence to clamping loss with reducing temperature. [2021-0141]
- 7 January 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Journal of Microelectromechanical Systems
- Vol. 31 (2) , 204-216
Open AccessEffects of Remote Boundary Conditions on Clamping Loss in Micromechanical Resonators
Clamping loss in micromechanical resonators can strongly depend on the boundary conditions far away from the actual vibrating structure because the acoustic wavelength greatly exceeds the device dimensions. We demonstrate a scheme for post-fabrication tuning of the clamping loss in flexural-mode and bulk-mode resonators by modifying the boundary conditions of the chip with the frame. The measured quality factor increases by more than an order-of-magnitude for the microcantilevers and more than a factor of three for the bulk-mode resonators when frame contact is minimized via suspension of the chip by wirebonds. We propose a two-degree-of-freedom fluctuation-dissipation model to describe the thermomechanical noise and forced response in the presence of this tunable anchor damping. By studying the thermomechanical displacement spectrum with tunable clamping loss, we show that variable clamping loss tunes the mechanical quality factor, modifying both the resonator transfer function and thermomechanical noise force. We delineate the dependence of the tunable clamping loss mechanism on microcantilever beam length and ambient temperature from 300 K down to 40 K, and observe potential temperature dependence to clamping loss with reducing temperature. [2021-0141]
- 8 January 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Journal of Microelectromechanical Systems
- Vol. 30 (2) , 193-202
Quantification of Energy Dissipation Mechanisms in Toroidal Ring Gyroscope
We present a study on the quantification of energy dissipation of Micro-Electro-Mechanical System (MEMS) resonators. Toroidal Ring Gyroscope (TRG) was used as a platform to conduct the study. The main energy dissipation mechanisms in TRG include viscous air damping, Thermo-Elastic Damping (TED), anchor loss, and surface loss. During our experimental study, these energy dissipation mechanisms were minimized and controlled by venting the encapsulation and actively pumping down to high vacuum, cooling the temperature down to around 123 K, adjusting modal balance by electrostatic tuning, and pre-baking the device at high temperature (425 °C), respectively. At room temperature, the quality factor related to viscous air damping was measured to be 625,000, TED to be 170,000, and anchor loss to be 1,350,000. Finite Element Analysis (FEA) was conducted to support these findings. Relation between the anchor loss and electrostatic tuning was also explored. The effects of moisture-related surface loss have also been demonstrated by monitoring characteristics over a 2-year period of time. High temperature bake-out was proven to be effective in removing the moisture and reducing the surface loss. This paper combines topics that are scattered in literature on identification of energy dissipation mechanisms in kilohertz-range silicon MEMS resonators and presents the topic as a single methodology illustrating how the contribution of each energy dissipation mechanism can be quantified independently. To the best of our knowledge, this study is the first to experimentally quantify all major energy dissipation mechanisms in a kilohertz-range silicon MEMS resonator. [2020-0294]
- 8 January 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Journal of Microelectromechanical Systems
- Vol. 30 (2) , 193-202
Quantification of Energy Dissipation Mechanisms in Toroidal Ring Gyroscope
We present a study on the quantification of energy dissipation of Micro-Electro-Mechanical System (MEMS) resonators. Toroidal Ring Gyroscope (TRG) was used as a platform to conduct the study. The main energy dissipation mechanisms in TRG include viscous air damping, Thermo-Elastic Damping (TED), anchor loss, and surface loss. During our experimental study, these energy dissipation mechanisms were minimized and controlled by venting the encapsulation and actively pumping down to high vacuum, cooling the temperature down to around 123 K, adjusting modal balance by electrostatic tuning, and pre-baking the device at high temperature (425 °C), respectively. At room temperature, the quality factor related to viscous air damping was measured to be 625,000, TED to be 170,000, and anchor loss to be 1,350,000. Finite Element Analysis (FEA) was conducted to support these findings. Relation between the anchor loss and electrostatic tuning was also explored. The effects of moisture-related surface loss have also been demonstrated by monitoring characteristics over a 2-year period of time. High temperature bake-out was proven to be effective in removing the moisture and reducing the surface loss. This paper combines topics that are scattered in literature on identification of energy dissipation mechanisms in kilohertz-range silicon MEMS resonators and presents the topic as a single methodology illustrating how the contribution of each energy dissipation mechanism can be quantified independently. To the best of our knowledge, this study is the first to experimentally quantify all major energy dissipation mechanisms in a kilohertz-range silicon MEMS resonator. [2020-0294]
- 30 November 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Journal of Microelectromechanical Systems
- Vol. 29 (6) , 1582
Correction to “Negative Nonlinear Dissipation in Microelectromechanical Beams” [20 954-959]
In the above article [1] , Reference [1] should have read as follows:
- 30 November 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Journal of Microelectromechanical Systems
- Vol. 29 (6) , 1582
Correction to “Negative Nonlinear Dissipation in Microelectromechanical Beams” [20 954-959]
In the above article [1] , Reference [1] should have read as follows:
- 14 August 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Journal of Microelectromechanical Systems
- Vol. 29 (5) , 1130-1131
Crystal Orientation Dependent Dual Frequency Ovenized MEMS Resonator With Temperature Stability and Shock Robustness
In this paper, we demonstrate a dual frequency oven-controlled MEMS resonator that can be designed to have an output frequency of 1.27 Mhz or 13 Mhz depending on the crystal orientation of the device. Both modes operate based on closed-loop thermal compensation that can offer PPB (parts-per-billion) level temperature stability over a wide temperature range using low power and exhibit strong shock robustness. As the device is rotated 45- degrees with respect to the plane of the wafer, the two modes used in oven control exhibit a unique temperature coefficient of frequency (tcF) reversal that allows selection of the output frequency for timing reference applications. The stiffer inplane mode has better temperature stability and shock resistance whereas the plate-bending mode offers ease of drive. Both devices retain stability performance after multiple 12,000g level shocks. [2020-0143]
- 14 August 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Journal of Microelectromechanical Systems
- Vol. 29 (5) , 1130-1131
Crystal Orientation Dependent Dual Frequency Ovenized MEMS Resonator With Temperature Stability and Shock Robustness
In this paper, we demonstrate a dual frequency oven-controlled MEMS resonator that can be designed to have an output frequency of 1.27 Mhz or 13 Mhz depending on the crystal orientation of the device. Both modes operate based on closed-loop thermal compensation that can offer PPB (parts-per-billion) level temperature stability over a wide temperature range using low power and exhibit strong shock robustness. As the device is rotated 45- degrees with respect to the plane of the wafer, the two modes used in oven control exhibit a unique temperature coefficient of frequency (tcF) reversal that allows selection of the output frequency for timing reference applications. The stiffer inplane mode has better temperature stability and shock resistance whereas the plate-bending mode offers ease of drive. Both devices retain stability performance after multiple 12,000g level shocks. [2020-0143]
- 7 August 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Journal of Microelectromechanical Systems
- Vol. 29 (5) , 860-866
Anchor Design Affects Dominant Energy Loss Mechanism in a Lamé Mode MEM Resonator
We present a Lamé mode resonator whose limiting damping mechanism depends on its anchor geometry. The device is anchor-limited when the anchors are stiffer and is Akhiezer-limited with more compliant anchors. This result is determined by observing the temperature dependence of the quality factor (Q) for devices with different lateral dimensions and different anchor designs. The total measured Q increases by an order of magnitude with the more compliant anchors and reaches a room temperature fxQ product of 2.2x10¹³. We studied the relationship between the device design and the anchor design and the measured Q(T) results to identify the contributions from different dissipation mechanisms. This investigation provides insight into how anchor design affects anchor damping. [2020-0195]
- 7 August 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Journal of Microelectromechanical Systems
- Vol. 29 (5) , 860-866
Anchor Design Affects Dominant Energy Loss Mechanism in a Lamé Mode MEM Resonator
We present a Lamé mode resonator whose limiting damping mechanism depends on its anchor geometry. The device is anchor-limited when the anchors are stiffer and is Akhiezer-limited with more compliant anchors. This result is determined by observing the temperature dependence of the quality factor (Q) for devices with different lateral dimensions and different anchor designs. The total measured Q increases by an order of magnitude with the more compliant anchors and reaches a room temperature fxQ product of 2.2x10¹³. We studied the relationship between the device design and the anchor design and the measured Q(T) results to identify the contributions from different dissipation mechanisms. This investigation provides insight into how anchor design affects anchor damping. [2020-0195]
- 14 July 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Journal of Microelectromechanical Systems
- Vol. 29 (5) , 954-959
Negative Nonlinear Dissipation in Microelectromechanical Beams
In this work we present measurements of drive-induced negative nonlinear dissipation present in doubly clamped microbeams fabricated in a hermetically sealed package. We characterize the amplitude-frequency nonlinearity and nonlinear dissipation present in this system under direct drive. The negative nature of the nonlinear dissipation is observed when measuring either the directly- or parametrically-actuated response. By comparing to the free ringdown response, we confirm that the nonlinear dissipation is induced by driving the resonator. Drive-induced nonlinear damping is an important consideration for resonant sensors and oscillators operated at large amplitudes. [2020-0140]
- 14 July 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Journal of Microelectromechanical Systems
- Vol. 29 (5) , 954-959
Negative Nonlinear Dissipation in Microelectromechanical Beams
In this work we present measurements of drive-induced negative nonlinear dissipation present in doubly clamped microbeams fabricated in a hermetically sealed package. We characterize the amplitude-frequency nonlinearity and nonlinear dissipation present in this system under direct drive. The negative nature of the nonlinear dissipation is observed when measuring either the directly- or parametrically-actuated response. By comparing to the free ringdown response, we confirm that the nonlinear dissipation is induced by driving the resonator. Drive-induced nonlinear damping is an important consideration for resonant sensors and oscillators operated at large amplitudes. [2020-0140]
- 10 July 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Journal of Microelectromechanical Systems
- Vol. 29 (5) , 1124-1126
Quality Factor Extraction and Enhancement Across Temperature in Ring Resonators
This work demonstrates that thin slots strategically placed in MEMS ring resonators are able to enhance the quality factor (Q) of the device operated in a wineglass mode in the isothermal region. The devices are optimized using COMSOL for an increased Q through increased slot size, using the Zener curve as a comparative baseline. These parts are fabricated and encapsulated in an ultra-clean environment, and tested in various temperature and pressure conditions to directly measure changes in anchor, gas, and thermoelastic dissipation across temperature. [2020-0156]
- 10 July 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Journal of Microelectromechanical Systems
- Vol. 29 (5) , 1124-1126
Quality Factor Extraction and Enhancement Across Temperature in Ring Resonators
This work demonstrates that thin slots strategically placed in MEMS ring resonators are able to enhance the quality factor (Q) of the device operated in a wineglass mode in the isothermal region. The devices are optimized using COMSOL for an increased Q through increased slot size, using the Zener curve as a comparative baseline. These parts are fabricated and encapsulated in an ultra-clean environment, and tested in various temperature and pressure conditions to directly measure changes in anchor, gas, and thermoelastic dissipation across temperature. [2020-0156]
- Open Access
- 18 February 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Journal of Microelectromechanical Systems
- Vol. 29 (2) , 190-201
Low-Power Dual Mode MEMS Resonators With PPB Stability Over Temperature
We demonstrate two novel dual-mode ovenized MEMS resonators, each with an in-chip device layer micro-oven that utilizes less than 30mW for resonator temperature control over variations in external temperature from -40°C to +60°C. The device layer micro-oven enables correction for ambient temperature variations and achieves a 1-week frequency stability for the output mode over temperature near 1.5 ppb for the Lamé-mode resonator. The devices were built in the Epi-Seal fabrication process and take advantage of the exceptional long-term stability of MEMS resonators built in that process. These results exceed all prior reports for frequency stability over time and temperature for MEMS resonators and have the potential to impact the development of miniature, low-power time references. [2019-0054]
- 18 February 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Journal of Microelectromechanical Systems
- Vol. 29 (2) , 190-201
Open AccessLow-Power Dual Mode MEMS Resonators With PPB Stability Over Temperature
We demonstrate two novel dual-mode ovenized MEMS resonators, each with an in-chip device layer micro-oven that utilizes less than 30mW for resonator temperature control over variations in external temperature from -40°C to +60°C. The device layer micro-oven enables correction for ambient temperature variations and achieves a 1-week frequency stability for the output mode over temperature near 1.5 ppb for the Lamé-mode resonator. The devices were built in the Epi-Seal fabrication process and take advantage of the exceptional long-term stability of MEMS resonators built in that process. These results exceed all prior reports for frequency stability over time and temperature for MEMS resonators and have the potential to impact the development of miniature, low-power time references. [2019-0054]
- 1 January 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1191-1194
Frequency Stabilization in an Encapsulated High-Q Micromechanical Resonator via Internal Resonance
The frequency stability is a key parameter to determine the performance of a micro-electro-mechanical (MEM) resonator. In this study, we utilized the mechanism of 1:2 internal resonance (IR) in a hermetically encapsulated beam resonator with a high Q-factor (>4000) to improve the frequency stability. When a MEM resonator is driven by a single-frequency actuation and conditions for IR are satisfied, two engaged modes are simultaneously resonated with their phases locked together through a strong and effective intermodal energy transfer. The increased inertia of these two active resonant modes leads to the frequency stabilization in both frequency outputs. In an open-loop experimental setting, we demonstrated that the IR achieved a six-fold improvement in the frequency stability. This paper reports the first implementation of IR in an encapsulated high-Q beam resonator.
- 1 January 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1191-1194
Frequency Stabilization in an Encapsulated High-Q Micromechanical Resonator via Internal Resonance
The frequency stability is a key parameter to determine the performance of a micro-electro-mechanical (MEM) resonator. In this study, we utilized the mechanism of 1:2 internal resonance (IR) in a hermetically encapsulated beam resonator with a high Q-factor (>4000) to improve the frequency stability. When a MEM resonator is driven by a single-frequency actuation and conditions for IR are satisfied, two engaged modes are simultaneously resonated with their phases locked together through a strong and effective intermodal energy transfer. The increased inertia of these two active resonant modes leads to the frequency stabilization in both frequency outputs. In an open-loop experimental setting, we demonstrated that the IR achieved a six-fold improvement in the frequency stability. This paper reports the first implementation of IR in an encapsulated high-Q beam resonator.