    Photoplethysmography behind the Ear Outperforms Electrocardiogram for Cardiovascular Monitoring in Dynamic Environments

    by Brian S. Bradke, Tiffany A. Miller, Bradford Everman

    An increasing proportion of occupational mishaps in dynamic, high-risk operational environments have been attributed to human error, yet there are currently no devices to routinely provide accurate physiological data for insights into underlying contributing factors. This is most commonly due to limitations of commercial and clinical devices for collecting physiological data in environments of high motion. Herein, a novel Photoplethysmography (PPG) sensor device was tested, called SPYDR (Standalone Performance Yielding Deliberate Risk), reading from a behind-the-ear location, specifically designed for high-fidelity data collection in highly dynamic high-motion, high-pressure, low-oxygen, and high-G-force environments. For this study, SPYDR was installed as a functional ear-cup replacement in flight helmets worn by rated US Navy aircrew. Subjects were exposed to reduced atmospheric pressure using a hypobaric chamber to simulated altitudes of 25,000 feet and high G-forces in a human-rated centrifuge up to 9 G acceleration. Data were compared to control devices, finger and forehead PPG sensors, and a chest-mounted 12-lead ECG. SPYDR produced high-fidelity data compared to controls with little motion-artifact controls in the no-motion environment of the hypobaric chamber. However, in the high-motion, high-force environment of the centrifuge, SPYDR recorded consistent, accurate data, whereas PPG controls and ECG data were unusable due to a high-degree-motion artifacts. The data demonstrate that SPYDR provides an accurate and reliable system for continuous physiological monitoring in high-motion, high-risk environments, yielding a novel method for collecting low-artifact cardiovascular assessment data important for investigating currently inaccessible parameters of human physiology.


  • Open Access

    Investigation of Photoplethysmography Behind the Ear for Pulse Oximetry in Hypoxic Conditions with a Novel Device (SPYDR)

    by Brian Bradke, Bradford Everman

    Photoplethysmography (PPG) is a valuable technique for noninvasively evaluating physiological parameters. However, traditional PPG devices have significant limitations in high-motion and low-perfusion environments. To overcome these limitations, we investigated the accuracy of a clinically novel PPG site using SPYDR®, a new PPG sensor suite, against arterial blood gas (ABG) measurements as well as other commercial PPG sensors at the finger and forehead in hypoxic environments. SPYDR utilizes a reflectance PPG sensor applied behind the ear, between the pinna and the hairline, on the mastoid process, above the sternocleidomastoid muscle, near the posterior auricular artery in a self-contained ear cup system. ABG revealed accuracy of SPYDR with a root mean square error of 2.61% at a 70–100% range, meeting FDA requirements for PPG sensor accuracy. Subjects were also instrumented with SPYDR, as well as finger and forehead PPG sensors, and pulse rate (PR) and oxygen saturation (SpO2) were measured and compared at various reduced oxygen profiles with a reduced oxygen breathing device (ROBD). SPYDR was shown to be as accurate as other sensors in reduced oxygen environments with a Pearson’s correlation >93% for PR and SpO2. In addition, SPYDR responded to changes in SpO2 up to 50 s faster than PPG measurements at the finger and forehead.