Jonathan Robidoux
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Jonathan Robidoux has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
Danny Brouard
2 shared publications- Danny Brouard
Affiliations Héma-Québec, Affaires Médicales et Innovation, Quebec City, QC, Canada, Département de Biochimie, de Microbiologie et de Bio-Informatique, Université Laval, Quebec City, QC, Canada
2 shared publications - Marie-Pierre Cayer
Affiliation Héma-Québec, Affaires Médicales et Innovation, Quebec City, QC, Canada
2 shared publications Steve J. Charette
Affiliations Département de Biochimie, de Microbiologie et de Bio-Informatique, Université Laval, Quebec City, QC, Canada, Institut de Biologie Intégrative et des Systèmes, Université Laval, Quebec City, QC, Canada
2 shared publications- Alexandre Delorme
Département de Chimie, Quebec Center for Advanced Materials, Regroupement Québécois sur les Matériaux de Pointe, and Centre Interdisciplinaire de Recherche sur le Cerveau et l'Apprentissage, Institut Courtois Université de Montréal Montréal Canada
1 shared publication Antoine Lewin
Héma‐Québec, Medical Affairs and Innovation Montreal Quebec Canada
1 shared publication
Latest Publications
- Open Access
- 22 October 2025
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 20 (10) , e0333558
Monitoring of Staphylococcus epidermidis biofilm formation on platelet storage bag surfaces
Platelet concentrates (PCs) are stored at 20–24˚C in a biologically favorable environment that may support bacterial growth. Staphylococcus epidermidis , a typical contaminant, can form biofilms in PCs, complicating detection and increasing the risk of transfusion-transmitted bacterial infections. The material composition and surface texture of PC storage bags may influence biofilm formation. The impact of different PC storage bag materials on S. epidermidis biofilm formation was evaluated using the ISO 4768:2023(E) crystal violet (CV) assay. Four surface conditions were tested: polyvinyl chloride (PVC) plasticized with n-butyryl-tri(n-hexyl)-citrate (BTHC) – both smooth and rough sides, PVC plasticized with tri-(2-ethylhexyl)-trimellitate (TEHTM) and ethylene-vinyl acetate (EVA). Coupons and bags made from each material were used in the experiments. Biofilm-positive S. epidermidis was cultured in tryptic soy broth (TSB), PCs and plasma and added on plastic coupons under static conditions or directly in the bags with agitation. Bacterial enumeration and CV assay were performed on days 2, 5, and 7. In TSB, EVA coupons significantly formed more biofilm than the smooth side of PVC-BTHC or TEHTM over seven days. In PCs, more biofilm formed on the rough side of PVC-BTHC coupons than the smooth side, with no other differences between plastics, suggesting similar biofilm amount across PC bag materials in the presence of platelets. No biofilm was detected on coupons in plasma. Under continuous agitation and reduced oxygen levels, only the rough side of PVC-BTHC showed significant biofilm formation in TSB in PC storage bags over seven days. These findings highlight the need for standardized biofilm testing and suggest that some plastics are more conducive to biofilm formation under static conditions. However, during blood bank storage (i.e., continuous agitation and reduced oxygen levels), biofilm formation is limited, regardless of the platelet bag material, thereby reducing the risk of undetected bacterial contamination.
- 22 October 2025
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 20 (10) , e0333558
Open AccessMonitoring of Staphylococcus epidermidis biofilm formation on platelet storage bag surfaces
Platelet concentrates (PCs) are stored at 20–24˚C in a biologically favorable environment that may support bacterial growth. Staphylococcus epidermidis , a typical contaminant, can form biofilms in PCs, complicating detection and increasing the risk of transfusion-transmitted bacterial infections. The material composition and surface texture of PC storage bags may influence biofilm formation. The impact of different PC storage bag materials on S. epidermidis biofilm formation was evaluated using the ISO 4768:2023(E) crystal violet (CV) assay. Four surface conditions were tested: polyvinyl chloride (PVC) plasticized with n-butyryl-tri(n-hexyl)-citrate (BTHC) – both smooth and rough sides, PVC plasticized with tri-(2-ethylhexyl)-trimellitate (TEHTM) and ethylene-vinyl acetate (EVA). Coupons and bags made from each material were used in the experiments. Biofilm-positive S. epidermidis was cultured in tryptic soy broth (TSB), PCs and plasma and added on plastic coupons under static conditions or directly in the bags with agitation. Bacterial enumeration and CV assay were performed on days 2, 5, and 7. In TSB, EVA coupons significantly formed more biofilm than the smooth side of PVC-BTHC or TEHTM over seven days. In PCs, more biofilm formed on the rough side of PVC-BTHC coupons than the smooth side, with no other differences between plastics, suggesting similar biofilm amount across PC bag materials in the presence of platelets. No biofilm was detected on coupons in plasma. Under continuous agitation and reduced oxygen levels, only the rough side of PVC-BTHC showed significant biofilm formation in TSB in PC storage bags over seven days. These findings highlight the need for standardized biofilm testing and suggest that some plastics are more conducive to biofilm formation under static conditions. However, during blood bank storage (i.e., continuous agitation and reduced oxygen levels), biofilm formation is limited, regardless of the platelet bag material, thereby reducing the risk of undetected bacterial contamination.
- Open Access
- 30 May 2025
- Published by Elsevier in The Microbe
- Vol. 7
Dynamic monitoring of Staphylococcus epidermidis biofilm formation using a microfluidic approach
- 30 May 2025
- Published by Elsevier in The Microbe
- Vol. 7
Open AccessDynamic monitoring of Staphylococcus epidermidis biofilm formation using a microfluidic approach
- Open Access
- 9 April 2024
- Published by Wiley in Transfusion
- Vol. 64 (5) , 881-892
A portable surface plasmon resonance (SPR) sensor for the detection of immunoglobulin A in plasma
Background: A life‐threatening anaphylactic shock can occur if a patient with undiagnosed immunoglobulin A (IgA) deficiency (i.e., IgA levels <500 ng/mL) receives IgA‐containing blood, hence the need for a rapid, point‐of‐care (POC) method for IgA deficiency screening. Enzyme‐linked immunosorbent assay (ELISA) is routinely used to detect IgA, but this method requires trained specialists and ≥24 h to obtain a result. We developed a surface plasmon resonance (SPR)‐based protocol to identify IgA‐deficient patients or donors within 1 h.Materials and Methods: The SPR sensor relies on the detection of IgAs captured by primary antibodies adsorbed on the SPR chip and quantified with secondary antibodies. The sensor was calibrated from 0 to 2000 ng/mL in buffer, IgA‐depleted human serum, and plasma samples from IgA‐deficient individuals. A critical concentration of 500 ng/mL was set for IgA deficiency. The optimized sensor was then tested on eight plasma samples with known IgA status (determined by ELISA), including five with IgA deficiency and three with normal IgA levels.Results: The limit of detection was estimated at 30 ng/mL in buffer and 400 ng/mL in diluted plasma. The results obtained fully agreed with ELISA among the eight plasma samples tested. The protocol distinguished IgA‐deficient from normal samples, even for samples with an IgA concentration closer to critical concentration.Discussion: In conclusion, we developed a reliable POC assay for the quantification of IgA in plasma. This test may permit POC testing at blood drives and centralized centers to maintain reserves of IgA‐deficient blood and in‐hospital testing of blood recipients.
- 9 April 2024
- Published by Wiley in Transfusion
- Vol. 64 (5) , 881-892
Open AccessA portable surface plasmon resonance (SPR) sensor for the detection of immunoglobulin A in plasma
Background: A life‐threatening anaphylactic shock can occur if a patient with undiagnosed immunoglobulin A (IgA) deficiency (i.e., IgA levels <500 ng/mL) receives IgA‐containing blood, hence the need for a rapid, point‐of‐care (POC) method for IgA deficiency screening. Enzyme‐linked immunosorbent assay (ELISA) is routinely used to detect IgA, but this method requires trained specialists and ≥24 h to obtain a result. We developed a surface plasmon resonance (SPR)‐based protocol to identify IgA‐deficient patients or donors within 1 h.Materials and Methods: The SPR sensor relies on the detection of IgAs captured by primary antibodies adsorbed on the SPR chip and quantified with secondary antibodies. The sensor was calibrated from 0 to 2000 ng/mL in buffer, IgA‐depleted human serum, and plasma samples from IgA‐deficient individuals. A critical concentration of 500 ng/mL was set for IgA deficiency. The optimized sensor was then tested on eight plasma samples with known IgA status (determined by ELISA), including five with IgA deficiency and three with normal IgA levels.Results: The limit of detection was estimated at 30 ng/mL in buffer and 400 ng/mL in diluted plasma. The results obtained fully agreed with ELISA among the eight plasma samples tested. The protocol distinguished IgA‐deficient from normal samples, even for samples with an IgA concentration closer to critical concentration.Discussion: In conclusion, we developed a reliable POC assay for the quantification of IgA in plasma. This test may permit POC testing at blood drives and centralized centers to maintain reserves of IgA‐deficient blood and in‐hospital testing of blood recipients.
- 1 April 2020
- Published by Wiley in Transfusion
- Vol. 60 (5) , 1032-1041
Development of a flow standard to enable highly reproducible measurements of deformability of stored red blood cells in a microfluidic device
BACKGROUND: Great deformability allows red blood cells (RBCs) to flow through narrow capillaries in tissues. A number of microfluidic devices with capillary‐like microchannels have been developed to monitor storage‐related impairment of RBC deformability during blood banking operations. This proof‐of‐concept study describes a new method to standardize and improve reproducibility of the RBC deformability measurements using one of these devices.STUDY DESIGN AND METHODS: The rate of RBC flow through the microfluidic capillary network of the microvascular analyzer (MVA) device made of polydimethylsiloxane was measured to assess RBC deformability. A suspension of microbeads in a solution of glycerol in phosphate‐buffered saline was developed to be used as an internal flow rate reference alongside RBC samples in the same device. RBC deformability and other in vitro quality markers were assessed weekly in six leukoreduced RBC concentrates (RCCs) dispersed in saline‐adenine‐glucose‐mannitol additive solution and stored over 42 days at 4°C.RESULTS: The use of flow reference reduced device‐to‐device measurement variability from 10% to 2%. Repeated‐measure analysis using the generalized estimating equation (GEE) method showed a significant monotonic decrease in relative RBC flow rate with storage from Week 0. By the end of storage, relative RBC flow rate decreased by 22 ± 6% on average.CONCLUSIONS: The suspension of microbeads was successfully used as a flow reference to increase reproducibility of RBC deformability measurements using the MVA. Deformability results suggest an early and late aging phase for stored RCCs, with significant decreases between successive weeks suggesting a highly sensitive measurement method.
- 1 April 2020
- Published by Wiley in Transfusion
- Vol. 60 (5) , 1032-1041
Development of a flow standard to enable highly reproducible measurements of deformability of stored red blood cells in a microfluidic device
BACKGROUND: Great deformability allows red blood cells (RBCs) to flow through narrow capillaries in tissues. A number of microfluidic devices with capillary‐like microchannels have been developed to monitor storage‐related impairment of RBC deformability during blood banking operations. This proof‐of‐concept study describes a new method to standardize and improve reproducibility of the RBC deformability measurements using one of these devices.STUDY DESIGN AND METHODS: The rate of RBC flow through the microfluidic capillary network of the microvascular analyzer (MVA) device made of polydimethylsiloxane was measured to assess RBC deformability. A suspension of microbeads in a solution of glycerol in phosphate‐buffered saline was developed to be used as an internal flow rate reference alongside RBC samples in the same device. RBC deformability and other in vitro quality markers were assessed weekly in six leukoreduced RBC concentrates (RCCs) dispersed in saline‐adenine‐glucose‐mannitol additive solution and stored over 42 days at 4°C.RESULTS: The use of flow reference reduced device‐to‐device measurement variability from 10% to 2%. Repeated‐measure analysis using the generalized estimating equation (GEE) method showed a significant monotonic decrease in relative RBC flow rate with storage from Week 0. By the end of storage, relative RBC flow rate decreased by 22 ± 6% on average.CONCLUSIONS: The suspension of microbeads was successfully used as a flow reference to increase reproducibility of RBC deformability measurements using the MVA. Deformability results suggest an early and late aging phase for stored RCCs, with significant decreases between successive weeks suggesting a highly sensitive measurement method.