Zachary J. Sasiene
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Zachary J. Sasiene has a total of 31 co-authors. Here are the top co-authors by number of shared publications:
- Glen P. Jackson
West Virginia University
7 shared publications - J. Tyler Davidson
Department of Forensic Science, Sam Houston State University, Huntsville, TX, USA
3 shared publications - David Ropartz
INRAE, UR BIA, F-44316 Nantes, France
2 shared publications - Guido F. Verbeck
Department of Chemistry and Biochemistry, Augusta University, Augusta, GA 30912, USA
2 shared publications Phillip M. Mach
Department of Chemistry, 1155 Union Circle #305070, University of North Texas, Denton, TX 76203, United States
2 shared publications- Praneeth M. Mendis
C. Eugene Bennett Department of Chemistry Morgantown, WV 26506-6121, USA
2 shared publications
Latest Publications
- Open Access
Conotoxin Prediction: New Features to Increase Prediction Accuracy
Conotoxins are toxic, disulfide-bond-rich peptides from cone snail venom that target a wide range of receptors and ion channels with multiple pathophysiological effects. Conotoxins have extraordinary potential for medical therapeutics that include cancer, microbial infections, epilepsy, autoimmune diseases, neurological conditions, and cardiovascular disorders. Despite the potential for these compounds in novel therapeutic treatment development, the process of identifying and characterizing the toxicities of conotoxins is difficult, costly, and time-consuming. This challenge requires a series of diverse, complex, and labor-intensive biological, toxicological, and analytical techniques for effective characterization. While recent attempts, using machine learning based solely on primary amino acid sequences to predict biological toxins (e.g., conotoxins and animal venoms), have improved toxin identification, these methods are limited due to peptide conformational flexibility and the high frequency of cysteines present in toxin sequences. This results in an enumerable set of disulfide-bridged foldamers with different conformations of the same primary amino acid sequence that affect function and toxicity levels. Consequently, a given peptide may be toxic when its cysteine residues form a particular disulfide-bond pattern, while alternative bonding patterns (isoforms) or its reduced form (free cysteines with no disulfide bridges) may have little or no toxicological effects. Similarly, the same disulfide-bond pattern may be possible for other peptide sequences and result in different conformations that all exhibit varying toxicities to the same receptor or to different receptors. We present here new features, when combined with primary sequence features to train machine learning algorithms to predict conotoxins, that significantly increase prediction accuracy.
Open AccessConotoxin Prediction: New Features to Increase Prediction Accuracy
Conotoxins are toxic, disulfide-bond-rich peptides from cone snail venom that target a wide range of receptors and ion channels with multiple pathophysiological effects. Conotoxins have extraordinary potential for medical therapeutics that include cancer, microbial infections, epilepsy, autoimmune diseases, neurological conditions, and cardiovascular disorders. Despite the potential for these compounds in novel therapeutic treatment development, the process of identifying and characterizing the toxicities of conotoxins is difficult, costly, and time-consuming. This challenge requires a series of diverse, complex, and labor-intensive biological, toxicological, and analytical techniques for effective characterization. While recent attempts, using machine learning based solely on primary amino acid sequences to predict biological toxins (e.g., conotoxins and animal venoms), have improved toxin identification, these methods are limited due to peptide conformational flexibility and the high frequency of cysteines present in toxin sequences. This results in an enumerable set of disulfide-bridged foldamers with different conformations of the same primary amino acid sequence that affect function and toxicity levels. Consequently, a given peptide may be toxic when its cysteine residues form a particular disulfide-bond pattern, while alternative bonding patterns (isoforms) or its reduced form (free cysteines with no disulfide bridges) may have little or no toxicological effects. Similarly, the same disulfide-bond pattern may be possible for other peptide sequences and result in different conformations that all exhibit varying toxicities to the same receptor or to different receptors. We present here new features, when combined with primary sequence features to train machine learning algorithms to predict conotoxins, that significantly increase prediction accuracy.
- Open Access
Configurational entropy-based screening and selection of hydrophilic polymers using the tripartite split green fluorescent protein
Measuring the entropic properties of polymers such as proteins is critical to accurate prediction of their functional properties. However, the measurement of configurational entropy is possible only by low throughput techniques such as calorimetry, NMR and CD spectroscopy. Moreover, to our knowledge no system exists that allows molecular selection/enrichment based on the molecules configurational entropy. We tested the ability of the scalable tripartite GFP system to offer fine resolution of differences in configurational entropy in molecules and to isolate molecules based on their configurational entropy. The system was able to both finely resolve molecules with different configurational entropies, as well as capture them for isolation. We were able to tune the sensitivity of the system by using different mutations of the protein components. Lastly, we were able to apply the system to polypeptoid molecules and posit that the system may be applied to any other hydrophilic polymer of up to 10^3 repeating units.
Open AccessConfigurational entropy-based screening and selection of hydrophilic polymers using the tripartite split green fluorescent protein
Measuring the entropic properties of polymers such as proteins is critical to accurate prediction of their functional properties. However, the measurement of configurational entropy is possible only by low throughput techniques such as calorimetry, NMR and CD spectroscopy. Moreover, to our knowledge no system exists that allows molecular selection/enrichment based on the molecules configurational entropy. We tested the ability of the scalable tripartite GFP system to offer fine resolution of differences in configurational entropy in molecules and to isolate molecules based on their configurational entropy. The system was able to both finely resolve molecules with different configurational entropies, as well as capture them for isolation. We were able to tune the sensitivity of the system by using different mutations of the protein components. Lastly, we were able to apply the system to polypeptoid molecules and posit that the system may be applied to any other hydrophilic polymer of up to 10^3 repeating units.
- 1 October 2021
- Published by Elsevier in International Journal of Mass Spectrometry
- Vol. 468
The influence of Na/H exchange on the charge transfer dissociation (CTD) spectra of mannuronic acid oligomers
- 1 October 2021
- Published by Elsevier in International Journal of Mass Spectrometry
- Vol. 468
The influence of Na/H exchange on the charge transfer dissociation (CTD) spectra of mannuronic acid oligomers
- 9 June 2021
- Published by Wiley in Journal of Mass Spectrometry
- Vol. 56 (7) , e4774
Charge transfer dissociation of a branched glycan with alkali and alkaline earth metal adducts
Alkali and alkaline earth metal adducts of a branched glycan, XXXG, were analyzed with helium charge transfer dissociation (He‐CTD) and low‐energy collision‐induced dissociation (LE‐CID) to investigate if metalation would impact the type of fragments generated and the structural characterization of the analyte. The studied adducts included 1+ and 2+ precursors involving one or more of the cations: H+, Na+, K+, Ca2+, and Mg2+. Regardless of the metal adduct, He‐CTD generated abundant and numerous glycosidic and cross‐ring cleavages that were structurally informative and able to identify the 1,4‐linkage and 1,6‐branching patterns. In contrast, the LE‐CID spectra mainly contained glycosidic cleavages, consecutive fragments, and numerous neutral losses, which complicated spectral interpretation. LE‐CID of [M + K + H]2+ and [M + Na]+ precursors generated a few cross‐ring cleavages, but they were not sufficient to identify the 1,4‐linkage and 1,6‐branching pattern of the XXXG xyloglucan. He‐CTD predominantly generated 1+ fragments from 1+ precursors and 2+ product ions from 2+ precursors, although both LE‐CID and He‐CTD were able to generate 1+ product ions from 2+ adducts of magnesium and calcium. The singly charged fragments derive from the loss of H+ from the metalated product ions and the formation of a protonated complementary product ion; such observations are similar to previous reports for magnesium and calcium salts undergoing electron capture dissociation (ECD) activation. However, during He‐CTD, the [M + Mg]2+ precursor generated more singly charged product ions than [M + Ca]2+, either because Mg has a higher second ionization potential than Ca or because of conformational differences and the locations of the charging adducts during fragmentation. He‐CTD of the [M + 2Na]2+ and the [M + 2 K]2+ precursors generated singly charged product ions from the loss of a sodium ion and potassium ion, respectively. In summary, although the metal ions influence the mass and charge state of the observed product ions, the metal ions had a negligible effect on the types of cross‐ring cleavages observed.
- 9 June 2021
- Published by Wiley in Journal of Mass Spectrometry
- Vol. 56 (7) , e4774
Charge transfer dissociation of a branched glycan with alkali and alkaline earth metal adducts
Alkali and alkaline earth metal adducts of a branched glycan, XXXG, were analyzed with helium charge transfer dissociation (He‐CTD) and low‐energy collision‐induced dissociation (LE‐CID) to investigate if metalation would impact the type of fragments generated and the structural characterization of the analyte. The studied adducts included 1+ and 2+ precursors involving one or more of the cations: H+, Na+, K+, Ca2+, and Mg2+. Regardless of the metal adduct, He‐CTD generated abundant and numerous glycosidic and cross‐ring cleavages that were structurally informative and able to identify the 1,4‐linkage and 1,6‐branching patterns. In contrast, the LE‐CID spectra mainly contained glycosidic cleavages, consecutive fragments, and numerous neutral losses, which complicated spectral interpretation. LE‐CID of [M + K + H]2+ and [M + Na]+ precursors generated a few cross‐ring cleavages, but they were not sufficient to identify the 1,4‐linkage and 1,6‐branching pattern of the XXXG xyloglucan. He‐CTD predominantly generated 1+ fragments from 1+ precursors and 2+ product ions from 2+ precursors, although both LE‐CID and He‐CTD were able to generate 1+ product ions from 2+ adducts of magnesium and calcium. The singly charged fragments derive from the loss of H+ from the metalated product ions and the formation of a protonated complementary product ion; such observations are similar to previous reports for magnesium and calcium salts undergoing electron capture dissociation (ECD) activation. However, during He‐CTD, the [M + Mg]2+ precursor generated more singly charged product ions than [M + Ca]2+, either because Mg has a higher second ionization potential than Ca or because of conformational differences and the locations of the charging adducts during fragmentation. He‐CTD of the [M + 2Na]2+ and the [M + 2 K]2+ precursors generated singly charged product ions from the loss of a sodium ion and potassium ion, respectively. In summary, although the metal ions influence the mass and charge state of the observed product ions, the metal ions had a negligible effect on the types of cross‐ring cleavages observed.
- 9 November 2020
- Published by Wiley in Journal of Mass Spectrometry
- Vol. 56 (2) , e4679
Comparison of in‐source collision‐induced dissociation and beam‐type collision‐induced dissociation of emerging synthetic drugs using a high‐resolution quadrupole time‐of‐flight mass spectrometer
In‐source collision‐induced dissociation (CID) is commonly used with single‐stage high‐resolution mass spectrometers to gather both a molecular formula and structural information through the collisional activation of analytes with residual background gas in the source region of the mass spectrometer. However, unlike tandem mass spectrometry, in‐source CID does not involve an isolation step prior to collisional activation leading to a product ion spectrum composed of fragment ions from any analyte present during the activation event. This work provides the first comparison of in‐source CID and beam‐type CID spectra of emerging synthetic drugs on the same instrument to understand the fragmentation differences between the two techniques and to contribute to the scientific foundations of in‐source CID. Electrospray ionization–quadrupole time‐of‐flight (ESI‐Q‐TOF) mass spectrometry was used to generate product ion spectra from in‐source CID and beam‐type CID for a series of well‐characterized fentanyl analogs and synthetic cathinones. A comparison between the fragmentation patterns and relative ion abundances for each technique was performed over a range of fragmentor offset voltages for in‐source CID and a range of collision energies for beam‐type CID. The results indicate that large fragmentor potentials for in‐source CID tend to favor higher energy fragmentation pathways that result in both kinetically favored pathways and consecutive neutral losses, both of which produce more abundant lower mass product ions relative to beam‐type CID. Although conditions can be found in which in‐source CID and beam‐type CID provide similar overall spectra, the in‐source CID spectra tend to contain elevated noise and additional chemical background peaks relative to beam‐type CID.
- 9 November 2020
- Published by Wiley in Journal of Mass Spectrometry
- Vol. 56 (2) , e4679
Comparison of in‐source collision‐induced dissociation and beam‐type collision‐induced dissociation of emerging synthetic drugs using a high‐resolution quadrupole time‐of‐flight mass spectrometer
In‐source collision‐induced dissociation (CID) is commonly used with single‐stage high‐resolution mass spectrometers to gather both a molecular formula and structural information through the collisional activation of analytes with residual background gas in the source region of the mass spectrometer. However, unlike tandem mass spectrometry, in‐source CID does not involve an isolation step prior to collisional activation leading to a product ion spectrum composed of fragment ions from any analyte present during the activation event. This work provides the first comparison of in‐source CID and beam‐type CID spectra of emerging synthetic drugs on the same instrument to understand the fragmentation differences between the two techniques and to contribute to the scientific foundations of in‐source CID. Electrospray ionization–quadrupole time‐of‐flight (ESI‐Q‐TOF) mass spectrometry was used to generate product ion spectra from in‐source CID and beam‐type CID for a series of well‐characterized fentanyl analogs and synthetic cathinones. A comparison between the fragmentation patterns and relative ion abundances for each technique was performed over a range of fragmentor offset voltages for in‐source CID and a range of collision energies for beam‐type CID. The results indicate that large fragmentor potentials for in‐source CID tend to favor higher energy fragmentation pathways that result in both kinetically favored pathways and consecutive neutral losses, both of which produce more abundant lower mass product ions relative to beam‐type CID. Although conditions can be found in which in‐source CID and beam‐type CID provide similar overall spectra, the in‐source CID spectra tend to contain elevated noise and additional chemical background peaks relative to beam‐type CID.
- 3 September 2020
- Published by American Chemical Society (ACS) in Journal of the American Society for Mass Spectrometry
- Vol. 31 (10) , 2143-2153
Structural Characterization of Sulfated Glycosaminoglycans Using Charge-Transfer Dissociation
Glycosaminoglycans (GAGs) participate in a broad range of physiological processes, and their structures are of interest to researchers in structural biology and medicine. Although they are abundant in tissues and extracellular matrices, their structural heterogeneity makes them challenging analytes. Mass spectrometry, and more specifically, tandem mass spectrometry, is particularly well suited for their analysis. Many tandem mass spectrometry techniques have been examined for their suitability towards the structural characterization of GAGs. Threshold activation methods such as collision induced dissociation (CID) produce mainly glycosidic cleavages and do not yield a broad range of structurally informative cross-ring fragments. Considerable research effort has been directed at finding other means of dissociating gas-phase GAG ions to produce more comprehensive structural information. Here, we compare the structural information of GAGs obtained by charge transfer dissociation (CTD) and electron detachment dissociation (EDD). EDD has previously been applied to GAGs and is known to produce both glycosidic and cross-ring cleavages in similar abundance. CTD has not previously been used to analyze GAGs but has been shown to produce abundant cross-ring cleavages and no sulfate loss when applied to another class of sulfated carbohydrates like algal polysaccharides. In contrast to EDD, which is restricted to FTICR mass spectrometers, CTD can be implemented on other platforms, such as ion trap mass spectrometers (ITMS). Here, we show the capability of CTD-ITMS to produce structurally significant details of the sites of modification in both heparan sulfate (HS) and chondroitin sulfate (CS) standards ranging in length from degree of polymerization (dp) 4 to dp6. EDD and CTD both yield more structural information than CID, and yield similar fractional abundances to one another for glycosidic fragments, cross-ring fragments and neutral losses.
- 3 September 2020
- Published by American Chemical Society (ACS) in Journal of the American Society for Mass Spectrometry
- Vol. 31 (10) , 2143-2153
Structural Characterization of Sulfated Glycosaminoglycans Using Charge-Transfer Dissociation
Glycosaminoglycans (GAGs) participate in a broad range of physiological processes, and their structures are of interest to researchers in structural biology and medicine. Although they are abundant in tissues and extracellular matrices, their structural heterogeneity makes them challenging analytes. Mass spectrometry, and more specifically, tandem mass spectrometry, is particularly well suited for their analysis. Many tandem mass spectrometry techniques have been examined for their suitability towards the structural characterization of GAGs. Threshold activation methods such as collision induced dissociation (CID) produce mainly glycosidic cleavages and do not yield a broad range of structurally informative cross-ring fragments. Considerable research effort has been directed at finding other means of dissociating gas-phase GAG ions to produce more comprehensive structural information. Here, we compare the structural information of GAGs obtained by charge transfer dissociation (CTD) and electron detachment dissociation (EDD). EDD has previously been applied to GAGs and is known to produce both glycosidic and cross-ring cleavages in similar abundance. CTD has not previously been used to analyze GAGs but has been shown to produce abundant cross-ring cleavages and no sulfate loss when applied to another class of sulfated carbohydrates like algal polysaccharides. In contrast to EDD, which is restricted to FTICR mass spectrometers, CTD can be implemented on other platforms, such as ion trap mass spectrometers (ITMS). Here, we show the capability of CTD-ITMS to produce structurally significant details of the sites of modification in both heparan sulfate (HS) and chondroitin sulfate (CS) standards ranging in length from degree of polymerization (dp) 4 to dp6. EDD and CTD both yield more structural information than CID, and yield similar fractional abundances to one another for glycosidic fragments, cross-ring fragments and neutral losses.
- 4 April 2020
- Published by Wiley in Drug Testing and Analysis
- Vol. 12 (7) , 957-967
The influence of chemical modifications on the fragmentation behavior of fentanyl and fentanyl‐related compounds in electrospray ionization tandem mass spectrometry
Fentanyl is a synthetic opioid that has been approved by the FDA as a general anesthetic because of its rapid onset and high potency. However, since 2013 an opioid epidemic involving fentanyl or fentanyl‐related compounds (FRCs) has swept the United States and caused numerous deaths in every state. The identification of novel FRCs is complicated by the rapid turnover of modifications to the core fentanyl structure. In this study, a series of 16 FRCs were analyzed using electrospray ionization tandem mass spectrometry (ESI‐MS/MS) to gain a deeper understanding of the conserved and unique fragmentation behaviors associated with substitution to the core fentanyl structure. This work provides an approach, based on the product ions from ESI‐MS/MS, to identify the modification site(s) on the core fentanyl structure for FRCs. Five common locations of substitution to the core fentanyl structure were used to assess the effect of substitution on the fragmentation behavior of FRCs. The proposed fragmentation pathways are supported through the combination of isotopic labeling, multi‐stage mass spectrometry (MSn), and accurate mass measurements with high‐resolution mass spectrometry (HRMS). The identification of primary product ions specific to regions of substitution provides an additional tool for the identification of the location of substitution to the core fentanyl structure, which ultimately will assist toxicologists and seized drug analysts in the identification of emerging FRCs.
- 4 April 2020
- Published by Wiley in Drug Testing and Analysis
- Vol. 12 (7) , 957-967
The influence of chemical modifications on the fragmentation behavior of fentanyl and fentanyl‐related compounds in electrospray ionization tandem mass spectrometry
Fentanyl is a synthetic opioid that has been approved by the FDA as a general anesthetic because of its rapid onset and high potency. However, since 2013 an opioid epidemic involving fentanyl or fentanyl‐related compounds (FRCs) has swept the United States and caused numerous deaths in every state. The identification of novel FRCs is complicated by the rapid turnover of modifications to the core fentanyl structure. In this study, a series of 16 FRCs were analyzed using electrospray ionization tandem mass spectrometry (ESI‐MS/MS) to gain a deeper understanding of the conserved and unique fragmentation behaviors associated with substitution to the core fentanyl structure. This work provides an approach, based on the product ions from ESI‐MS/MS, to identify the modification site(s) on the core fentanyl structure for FRCs. Five common locations of substitution to the core fentanyl structure were used to assess the effect of substitution on the fragmentation behavior of FRCs. The proposed fragmentation pathways are supported through the combination of isotopic labeling, multi‐stage mass spectrometry (MSn), and accurate mass measurements with high‐resolution mass spectrometry (HRMS). The identification of primary product ions specific to regions of substitution provides an additional tool for the identification of the location of substitution to the core fentanyl structure, which ultimately will assist toxicologists and seized drug analysts in the identification of emerging FRCs.
- 3 January 2020
- Published by Wiley in Drug Testing and Analysis
- Vol. 12 (4) , 496-503
The characterization of isobaric product ions of fentanyl using multi‐stage mass spectrometry, high‐resolution mass spectrometry and isotopic labeling
This study uses a combination of multi‐stage mass spectrometry (MSn), accurate mass measurements – with high‐resolution mass spectrometry (HRMS) – and isotopic labeling to characterize the fragmentation behavior of fentanyl and 4‐ANPP. By understanding the fragmentation behavior of fentanyl and its analogs in more detail, toxicologists and seized drug analysts will be better poised to identify new and emerging fentalogs, which are increasingly common and deadly adulterants in the growing opioid crisis. Throughout the literature the product ion at m/z 188 is often the most abundant fragment in the mass spectrometric analysis of fentanyl and fentanyl analogs, and this fragment is used for both qualitative and quantitative determinations. Our work shows there are at least three different structures for the isobaric fentanyl product ions at m/z 188, and they each form and fragment via different pathways. The development of fragmentation mechanisms to explain the observed fragmentation pathways of fentanyl and its main precursor 4‐ANPP helps contribute to the advancement of knowledge about fentanyl fragmentation and could provide important information for the identification of future fentanyl analogs.
- 3 January 2020
- Published by Wiley in Drug Testing and Analysis
- Vol. 12 (4) , 496-503
The characterization of isobaric product ions of fentanyl using multi‐stage mass spectrometry, high‐resolution mass spectrometry and isotopic labeling
This study uses a combination of multi‐stage mass spectrometry (MSn), accurate mass measurements – with high‐resolution mass spectrometry (HRMS) – and isotopic labeling to characterize the fragmentation behavior of fentanyl and 4‐ANPP. By understanding the fragmentation behavior of fentanyl and its analogs in more detail, toxicologists and seized drug analysts will be better poised to identify new and emerging fentalogs, which are increasingly common and deadly adulterants in the growing opioid crisis. Throughout the literature the product ion at m/z 188 is often the most abundant fragment in the mass spectrometric analysis of fentanyl and fentanyl analogs, and this fragment is used for both qualitative and quantitative determinations. Our work shows there are at least three different structures for the isobaric fentanyl product ions at m/z 188, and they each form and fragment via different pathways. The development of fragmentation mechanisms to explain the observed fragmentation pathways of fentanyl and its main precursor 4‐ANPP helps contribute to the advancement of knowledge about fentanyl fragmentation and could provide important information for the identification of future fentanyl analogs.
- 1 September 2016
- Published by Elsevier in Science & Justice
- Vol. 56 (5) , 329-340
Laser ablation coupled with DAPNe-NSI-MS applied to redacted documents
- 1 September 2016
- Published by Elsevier in Science & Justice
- Vol. 56 (5) , 329-340
Laser ablation coupled with DAPNe-NSI-MS applied to redacted documents