Hong Chang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Hong Chang has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
- Wei Zhou
School of Civil Engineering, Harbin Institute of Technology, Harbin 150090, China
5 shared publications - Changhai Zhai
Key Lab of Structures Dynamic Behavior and Control of the Ministry of Education Harbin Institute of Technology Harbin China
3 shared publications - Zhibo Bao
School of Civil Engineering, Harbin Institute of Technology, Harbin 150090, China
2 shared publications - Dongmei Wang
China Nuclear Power Engineering Co., Ltd., Beijing 100840, China
1 shared publication
Latest Publications
- Open Access
Seismic Performance of In-Plane Loaded Modular Squat Shear Walls and the Influence of Post-Cast Strips
This study investigates modular low-rise shear walls by designing and fabricating four in-plane loaded specimens at a scale ratio of 1:2.7. Quasi-static low-cycle reversed loading tests combined with numerical simulations were systematically conducted to examine the effects of the type and location of post-cast strips on the seismic performance of shear walls. The experimental program comparatively analyzed crack development patterns, failure modes, and seismic performance indices of specimens with four construction configurations: without post-cast strips, with only a horizontal post-cast strip, with a horizontal post-cast strip combined with an eccentrically placed vertical post-cast strip, and with a horizontal post-cast strip combined with a centrally placed vertical post-cast strip. The results indicate that specimens without post-cast strips exhibit uniformly distributed and highly penetrative cracks, characterized by typical global shear failure. The horizontal post-cast strip restricts downward crack propagation, leading to crack concentration above the post-cast strip, whereas the combined arrangement of horizontal and vertical post-cast strips promotes dispersed crack development and significantly alleviates excessive local damage concentration. The specimen with a centrally located vertical post-cast strip exhibited the best overall seismic performance, characterized by full hysteretic curves, the largest cumulative energy dissipation, and the most gradual stiffness degradation, whereas the specimen with only a horizontal post-cast strip showed relatively poor energy dissipation capacity and ductility. The finite element model established based on the experimental results accurately reproduces the mechanical responses and failure characteristics of all specimens, validating the mechanism by which post-cast strips improve wall performance through stress dispersion and crack development regulation. The findings demonstrate that a rational arrangement of post-cast strips, particularly the adoption of a centrally placed vertical post-cast strip, can effectively enhance the seismic performance of modular low-rise shear walls.
Open AccessSeismic Performance of In-Plane Loaded Modular Squat Shear Walls and the Influence of Post-Cast Strips
This study investigates modular low-rise shear walls by designing and fabricating four in-plane loaded specimens at a scale ratio of 1:2.7. Quasi-static low-cycle reversed loading tests combined with numerical simulations were systematically conducted to examine the effects of the type and location of post-cast strips on the seismic performance of shear walls. The experimental program comparatively analyzed crack development patterns, failure modes, and seismic performance indices of specimens with four construction configurations: without post-cast strips, with only a horizontal post-cast strip, with a horizontal post-cast strip combined with an eccentrically placed vertical post-cast strip, and with a horizontal post-cast strip combined with a centrally placed vertical post-cast strip. The results indicate that specimens without post-cast strips exhibit uniformly distributed and highly penetrative cracks, characterized by typical global shear failure. The horizontal post-cast strip restricts downward crack propagation, leading to crack concentration above the post-cast strip, whereas the combined arrangement of horizontal and vertical post-cast strips promotes dispersed crack development and significantly alleviates excessive local damage concentration. The specimen with a centrally located vertical post-cast strip exhibited the best overall seismic performance, characterized by full hysteretic curves, the largest cumulative energy dissipation, and the most gradual stiffness degradation, whereas the specimen with only a horizontal post-cast strip showed relatively poor energy dissipation capacity and ductility. The finite element model established based on the experimental results accurately reproduces the mechanical responses and failure characteristics of all specimens, validating the mechanism by which post-cast strips improve wall performance through stress dispersion and crack development regulation. The findings demonstrate that a rational arrangement of post-cast strips, particularly the adoption of a centrally placed vertical post-cast strip, can effectively enhance the seismic performance of modular low-rise shear walls.
- Open Access
Seismic Performance Analysis of Squat Symmetric Shear Walls: Based on Different Reinforcement Ratios
To tackle the safety performance concerns of Squat shear walls in nuclear island structures (which serve as shields for powerhouses) under seismic action, this research endeavors to explore the seismic performance of such shear walls with different reinforcement ratios. Pseudo-static loading tests were carried out on 6 shear wall specimens, which were divided into 3 groups (with different reinforcement ratios). The focus was on analyzing the specimens’ failure process, load-deformation hysteretic curves, shear strength, ductility, strain, and other crucial parameters. The experimental findings demonstrate that all specimens underwent shear failure, which was characterized by the compression of web concrete. A higher reinforcement ratio can alleviate the buckling extent of structural steel. Specifically, an elevated horizontally distributed steel ratio notably enhances the ductility and energy dissipation capacity of the specimens, thereby effectively improving the yield load, stiffness, and ductility of squat shear walls. Nevertheless, its influence on cumulative energy dissipation and crack development is limited. Based on the analysis of the specimens’ failure modes, hysteretic curves, skeleton curves, energy dissipation, and stiffness degradation laws, finite-element numerical analysis was carried out on selected specimens. Comparison with the experimental results showed a good consistency between the two. Ultimately, the influence of the reinforcement ratio on the seismic performance of the shear walls was ascertained, and the research on the variation rules of the seismic performance parameters of squat shear walls was completed after verification through finite-element modeling. Based on this, a nonlinear fitting approach was employed to construct a regression prediction model for the seismic performance of shear walls in the Hainan Changjiang Multipurpose Modular Small Reactor Technology Demonstration Project. Typical squat shear walls were chosen for seismic response analysis, and the corresponding outcomes were acquired. Finally, a series of seismic vulnerability curves for nuclear island shear walls with varying guarantee rates were formulated for verification.
Open AccessSeismic Performance Analysis of Squat Symmetric Shear Walls: Based on Different Reinforcement Ratios
To tackle the safety performance concerns of Squat shear walls in nuclear island structures (which serve as shields for powerhouses) under seismic action, this research endeavors to explore the seismic performance of such shear walls with different reinforcement ratios. Pseudo-static loading tests were carried out on 6 shear wall specimens, which were divided into 3 groups (with different reinforcement ratios). The focus was on analyzing the specimens’ failure process, load-deformation hysteretic curves, shear strength, ductility, strain, and other crucial parameters. The experimental findings demonstrate that all specimens underwent shear failure, which was characterized by the compression of web concrete. A higher reinforcement ratio can alleviate the buckling extent of structural steel. Specifically, an elevated horizontally distributed steel ratio notably enhances the ductility and energy dissipation capacity of the specimens, thereby effectively improving the yield load, stiffness, and ductility of squat shear walls. Nevertheless, its influence on cumulative energy dissipation and crack development is limited. Based on the analysis of the specimens’ failure modes, hysteretic curves, skeleton curves, energy dissipation, and stiffness degradation laws, finite-element numerical analysis was carried out on selected specimens. Comparison with the experimental results showed a good consistency between the two. Ultimately, the influence of the reinforcement ratio on the seismic performance of the shear walls was ascertained, and the research on the variation rules of the seismic performance parameters of squat shear walls was completed after verification through finite-element modeling. Based on this, a nonlinear fitting approach was employed to construct a regression prediction model for the seismic performance of shear walls in the Hainan Changjiang Multipurpose Modular Small Reactor Technology Demonstration Project. Typical squat shear walls were chosen for seismic response analysis, and the corresponding outcomes were acquired. Finally, a series of seismic vulnerability curves for nuclear island shear walls with varying guarantee rates were formulated for verification.
- Open Access
Experimental Analysis of Seismic Behavior of Squat Shear Walls with Different Axial Load Ratios
The majority of existing experimental studies on the seismic performance of squat shear walls have primarily focused on small-scale specimens with low axial load ratios. To investigate the seismic behavior of squat reinforced concrete shear walls subjected to high axial load ratios, quasi-static tests were conducted on six large-scale squat shear walls with varying axial load ratios. The failure modes, hysteresis curves, skeleton curves, energy dissipation characteristics, stiffness degradation, and crack widths of these specimens were thoroughly analyzed. A numerical simulation of the experimental process was carried out using ABAQUS, and the validity of the finite element model and the accuracy of the numerical analysis results were verified through comparison with the experimental measurements. From the experimental results, it is determined that the axial load ratio is an important parameter affecting the specimens and that the squat shear walls show obvious shear slip failure. Furthermore, the axial load ratio is inversely proportional to the horizontal bearing capacity, stiffness, and ductility. ABAQUS is shown to simulate the stress state of the squat shear wall well, providing a reasonable theoretical analysis model and calculation parameters.
Open AccessExperimental Analysis of Seismic Behavior of Squat Shear Walls with Different Axial Load Ratios
The majority of existing experimental studies on the seismic performance of squat shear walls have primarily focused on small-scale specimens with low axial load ratios. To investigate the seismic behavior of squat reinforced concrete shear walls subjected to high axial load ratios, quasi-static tests were conducted on six large-scale squat shear walls with varying axial load ratios. The failure modes, hysteresis curves, skeleton curves, energy dissipation characteristics, stiffness degradation, and crack widths of these specimens were thoroughly analyzed. A numerical simulation of the experimental process was carried out using ABAQUS, and the validity of the finite element model and the accuracy of the numerical analysis results were verified through comparison with the experimental measurements. From the experimental results, it is determined that the axial load ratio is an important parameter affecting the specimens and that the squat shear walls show obvious shear slip failure. Furthermore, the axial load ratio is inversely proportional to the horizontal bearing capacity, stiffness, and ductility. ABAQUS is shown to simulate the stress state of the squat shear wall well, providing a reasonable theoretical analysis model and calculation parameters.
- Open Access
- 6 April 2020
- Published by Wiley in Mathematical Problems in Engineering
- Vol. 2020, 1-13
Flexural Behaviour of Unbonded Posttensioned Concrete Beam Strengthened with Aluminium Alloy Plates
Owing to their high corrosion resistance, aluminium alloy (AA) plates bonded with magnesium phosphate cement (MPC) are considered as a viable candidate for reinforcing inshore infrastructures that are subject to severe environmental conditions and vapor atmospheres. Therefore, the aim of this study is the evaluation of the flexural behaviour of simple beams that are strengthened using this technique. Six unbonded posttensioned concrete (UPC) beams with different reinforcement ratios are damaged by static loads and then repaired and strengthened using AA plates. The failures under two-point loading are then investigated. Thereafter, a simplified method is proposed for the evaluation of the flexural strength of a UPC beam strengthened by an AA plate with MPC. The flexural strengths of the six specimens increase by an average of 14%, and the displacement ductility factor decreases by an average of 34.14%. Moreover, the increase and decrease ratios are proportional and inversely proportional to the comprehensive reinforcement index, respectively. The influences of the three main factors on the flexural strength of the AA plate are determined: the increase in the stress of the unbonded tendons, stress at the midspan and slippage at the ends of the AA plate, and increase ratio of the flexural strength. It shows that the AA plates bonded with MPC can be used successfully in concrete strengthening.
- 6 April 2020
- Published by Wiley in Mathematical Problems in Engineering
- Vol. 2020, 1-13
Open AccessFlexural Behaviour of Unbonded Posttensioned Concrete Beam Strengthened with Aluminium Alloy Plates
Owing to their high corrosion resistance, aluminium alloy (AA) plates bonded with magnesium phosphate cement (MPC) are considered as a viable candidate for reinforcing inshore infrastructures that are subject to severe environmental conditions and vapor atmospheres. Therefore, the aim of this study is the evaluation of the flexural behaviour of simple beams that are strengthened using this technique. Six unbonded posttensioned concrete (UPC) beams with different reinforcement ratios are damaged by static loads and then repaired and strengthened using AA plates. The failures under two-point loading are then investigated. Thereafter, a simplified method is proposed for the evaluation of the flexural strength of a UPC beam strengthened by an AA plate with MPC. The flexural strengths of the six specimens increase by an average of 14%, and the displacement ductility factor decreases by an average of 34.14%. Moreover, the increase and decrease ratios are proportional and inversely proportional to the comprehensive reinforcement index, respectively. The influences of the three main factors on the flexural strength of the AA plate are determined: the increase in the stress of the unbonded tendons, stress at the midspan and slippage at the ends of the AA plate, and increase ratio of the flexural strength. It shows that the AA plates bonded with MPC can be used successfully in concrete strengthening.
- Open Access
- 1 January 2020
- Published by Wiley in Advances in Civil Engineering
- Vol. 2020 (1)
Stiffness and Crack Behavior of Unbonded Posttensioned Concrete Beam Strengthened with Aluminum Alloy Plate
Corrosion resistance of aluminum alloy plates externally bonded by magnesium phosphate cement provides the ability to strengthen inshore infrastructures in harsh environments subject to moisture and humidity. In this study, the aim is to study the stiffness and cracking behavior of concrete beams using this strengthening technique. Six damaged unbonded posttensioned concrete beams were repaired and strengthened and then subjected to monotonic load until failure. This technique improved the stiffness and limited the development of cracks. The formula of elastic‐plastic stiffness coefficient related to the comprehensive reinforcement index was established. An influence coefficient δ considering the effect of aluminum alloy plates and unbonded tendons was introduced, and the crack expansion coefficient under short‐term load was obtained by statistical analysis. Finally, some simplified methods were proposed to evaluate the stiffness and cracks of unbonded posttensioned concrete beams strengthened with aluminum alloy plates.
- 1 January 2020
- Published by Wiley in Advances in Civil Engineering
- Vol. 2020 (1)
Open AccessStiffness and Crack Behavior of Unbonded Posttensioned Concrete Beam Strengthened with Aluminum Alloy Plate
Corrosion resistance of aluminum alloy plates externally bonded by magnesium phosphate cement provides the ability to strengthen inshore infrastructures in harsh environments subject to moisture and humidity. In this study, the aim is to study the stiffness and cracking behavior of concrete beams using this strengthening technique. Six damaged unbonded posttensioned concrete beams were repaired and strengthened and then subjected to monotonic load until failure. This technique improved the stiffness and limited the development of cracks. The formula of elastic‐plastic stiffness coefficient related to the comprehensive reinforcement index was established. An influence coefficient δ considering the effect of aluminum alloy plates and unbonded tendons was introduced, and the crack expansion coefficient under short‐term load was obtained by statistical analysis. Finally, some simplified methods were proposed to evaluate the stiffness and cracks of unbonded posttensioned concrete beams strengthened with aluminum alloy plates.