Zhibo Bao
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Zhibo Bao has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Wei Zhou
School of Civil Engineering, Harbin Institute of Technology, Harbin 150090, China
3 shared publications - Changhai Zhai
Key Lab of Structures Dynamic Behavior and Control of the Ministry of Education Harbin Institute of Technology Harbin China
2 shared publications - Hong Chang
School of Civil Engineering, Harbin Institute of Technology, Harbin 150090, China
2 shared publications - Bolun Shi
Guangzhou Metro Design & Research Institute Co., Ltd., Guangzhou 510420, China
1 shared publication - Dongmei Wang
China Nuclear Power Engineering Co., Ltd., Beijing 100840, China
1 shared publication - Mingmin Wang
Guangzhou Metro Design & Research Institute Co., Ltd., Guangzhou 510420, China
1 shared publication
Latest Publications
- Open Access
A Filter Method for Dynamic Monitoring Data of Masonry Partition Walls in Subway Stations Based on a Butterworth Filter
Under the combined effects of vibrations from train operations and wind loads, the dynamic response monitoring data of masonry partition walls in subway stations are often contaminated with high-frequency noise, which hinders the accurate identification of the structure’s true dynamic characteristics. To tackle this problem, this paper proposes employing a Butterworth low-pass filter to process the on-site monitoring data. The paper initially elaborates on the monitoring theory grounded in the pulsation method, followed by a detailed explanation of the rationale for selecting the Butterworth filter, as well as data processing techniques such as Fast Fourier Transform (FFT) and self-power spectrum analysis. By incorporating a field monitoring case from a subway station in Guangzhou, the paper compares and analyzes the acceleration time-history curves before and after filtering. Additionally, finite element analysis is performed to assess the mechanical response of the masonry wall under wind loads, train-induced vibrations, and their combined effects. The results demonstrate that after applying a 4th-order Butterworth low-pass filter with a 46 Hz cutoff frequency, the high-frequency noise in the data is effectively suppressed, thereby accentuating the main trend and low-frequency vibration characteristics of the signal. This provides a reliable data foundation for subsequent precise analysis of the dynamic response and fatigue performance of the masonry walls.
Open AccessA Filter Method for Dynamic Monitoring Data of Masonry Partition Walls in Subway Stations Based on a Butterworth Filter
Under the combined effects of vibrations from train operations and wind loads, the dynamic response monitoring data of masonry partition walls in subway stations are often contaminated with high-frequency noise, which hinders the accurate identification of the structure’s true dynamic characteristics. To tackle this problem, this paper proposes employing a Butterworth low-pass filter to process the on-site monitoring data. The paper initially elaborates on the monitoring theory grounded in the pulsation method, followed by a detailed explanation of the rationale for selecting the Butterworth filter, as well as data processing techniques such as Fast Fourier Transform (FFT) and self-power spectrum analysis. By incorporating a field monitoring case from a subway station in Guangzhou, the paper compares and analyzes the acceleration time-history curves before and after filtering. Additionally, finite element analysis is performed to assess the mechanical response of the masonry wall under wind loads, train-induced vibrations, and their combined effects. The results demonstrate that after applying a 4th-order Butterworth low-pass filter with a 46 Hz cutoff frequency, the high-frequency noise in the data is effectively suppressed, thereby accentuating the main trend and low-frequency vibration characteristics of the signal. This provides a reliable data foundation for subsequent precise analysis of the dynamic response and fatigue performance of the masonry walls.
- Open Access
Seismic Performance Analysis of Squat Symmetric Shear Walls: Based on Different Reinforcement Ratios
To tackle the safety performance concerns of Squat shear walls in nuclear island structures (which serve as shields for powerhouses) under seismic action, this research endeavors to explore the seismic performance of such shear walls with different reinforcement ratios. Pseudo-static loading tests were carried out on 6 shear wall specimens, which were divided into 3 groups (with different reinforcement ratios). The focus was on analyzing the specimens’ failure process, load-deformation hysteretic curves, shear strength, ductility, strain, and other crucial parameters. The experimental findings demonstrate that all specimens underwent shear failure, which was characterized by the compression of web concrete. A higher reinforcement ratio can alleviate the buckling extent of structural steel. Specifically, an elevated horizontally distributed steel ratio notably enhances the ductility and energy dissipation capacity of the specimens, thereby effectively improving the yield load, stiffness, and ductility of squat shear walls. Nevertheless, its influence on cumulative energy dissipation and crack development is limited. Based on the analysis of the specimens’ failure modes, hysteretic curves, skeleton curves, energy dissipation, and stiffness degradation laws, finite-element numerical analysis was carried out on selected specimens. Comparison with the experimental results showed a good consistency between the two. Ultimately, the influence of the reinforcement ratio on the seismic performance of the shear walls was ascertained, and the research on the variation rules of the seismic performance parameters of squat shear walls was completed after verification through finite-element modeling. Based on this, a nonlinear fitting approach was employed to construct a regression prediction model for the seismic performance of shear walls in the Hainan Changjiang Multipurpose Modular Small Reactor Technology Demonstration Project. Typical squat shear walls were chosen for seismic response analysis, and the corresponding outcomes were acquired. Finally, a series of seismic vulnerability curves for nuclear island shear walls with varying guarantee rates were formulated for verification.
Open AccessSeismic Performance Analysis of Squat Symmetric Shear Walls: Based on Different Reinforcement Ratios
To tackle the safety performance concerns of Squat shear walls in nuclear island structures (which serve as shields for powerhouses) under seismic action, this research endeavors to explore the seismic performance of such shear walls with different reinforcement ratios. Pseudo-static loading tests were carried out on 6 shear wall specimens, which were divided into 3 groups (with different reinforcement ratios). The focus was on analyzing the specimens’ failure process, load-deformation hysteretic curves, shear strength, ductility, strain, and other crucial parameters. The experimental findings demonstrate that all specimens underwent shear failure, which was characterized by the compression of web concrete. A higher reinforcement ratio can alleviate the buckling extent of structural steel. Specifically, an elevated horizontally distributed steel ratio notably enhances the ductility and energy dissipation capacity of the specimens, thereby effectively improving the yield load, stiffness, and ductility of squat shear walls. Nevertheless, its influence on cumulative energy dissipation and crack development is limited. Based on the analysis of the specimens’ failure modes, hysteretic curves, skeleton curves, energy dissipation, and stiffness degradation laws, finite-element numerical analysis was carried out on selected specimens. Comparison with the experimental results showed a good consistency between the two. Ultimately, the influence of the reinforcement ratio on the seismic performance of the shear walls was ascertained, and the research on the variation rules of the seismic performance parameters of squat shear walls was completed after verification through finite-element modeling. Based on this, a nonlinear fitting approach was employed to construct a regression prediction model for the seismic performance of shear walls in the Hainan Changjiang Multipurpose Modular Small Reactor Technology Demonstration Project. Typical squat shear walls were chosen for seismic response analysis, and the corresponding outcomes were acquired. Finally, a series of seismic vulnerability curves for nuclear island shear walls with varying guarantee rates were formulated for verification.
- Open Access
Experimental Analysis of Seismic Behavior of Squat Shear Walls with Different Axial Load Ratios
The majority of existing experimental studies on the seismic performance of squat shear walls have primarily focused on small-scale specimens with low axial load ratios. To investigate the seismic behavior of squat reinforced concrete shear walls subjected to high axial load ratios, quasi-static tests were conducted on six large-scale squat shear walls with varying axial load ratios. The failure modes, hysteresis curves, skeleton curves, energy dissipation characteristics, stiffness degradation, and crack widths of these specimens were thoroughly analyzed. A numerical simulation of the experimental process was carried out using ABAQUS, and the validity of the finite element model and the accuracy of the numerical analysis results were verified through comparison with the experimental measurements. From the experimental results, it is determined that the axial load ratio is an important parameter affecting the specimens and that the squat shear walls show obvious shear slip failure. Furthermore, the axial load ratio is inversely proportional to the horizontal bearing capacity, stiffness, and ductility. ABAQUS is shown to simulate the stress state of the squat shear wall well, providing a reasonable theoretical analysis model and calculation parameters.
Open AccessExperimental Analysis of Seismic Behavior of Squat Shear Walls with Different Axial Load Ratios
The majority of existing experimental studies on the seismic performance of squat shear walls have primarily focused on small-scale specimens with low axial load ratios. To investigate the seismic behavior of squat reinforced concrete shear walls subjected to high axial load ratios, quasi-static tests were conducted on six large-scale squat shear walls with varying axial load ratios. The failure modes, hysteresis curves, skeleton curves, energy dissipation characteristics, stiffness degradation, and crack widths of these specimens were thoroughly analyzed. A numerical simulation of the experimental process was carried out using ABAQUS, and the validity of the finite element model and the accuracy of the numerical analysis results were verified through comparison with the experimental measurements. From the experimental results, it is determined that the axial load ratio is an important parameter affecting the specimens and that the squat shear walls show obvious shear slip failure. Furthermore, the axial load ratio is inversely proportional to the horizontal bearing capacity, stiffness, and ductility. ABAQUS is shown to simulate the stress state of the squat shear wall well, providing a reasonable theoretical analysis model and calculation parameters.