WZWei Zhang

Wei Zhang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Wei Zhang has a total of 23 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Comparison of Intramedullary Nail and Volar Locking Plate for Distal Radius Fractures: A Systematic Review and Meta-Analysis of Randomised Controlled Trials

    by Zehong Chen, Yinan Zhu, Wei Zhang, Hassan Eltagy, Sherif Elerian

    Operative intervention with a volar locking plate (VLP) is currently the gold standard for the fixation of distal radius fractures. Intramedullary nailing (IMN) of the distal radius is a novel technique that aims to reduce soft tissue complications due to a smaller surgical incision while maintaining the benefits of a rigid fracture fixation. The aim of this systematic review and meta-analysis was to investigate the functional, clinical, and radiological outcomes of all published randomised controlled trials (RCTs) comparing patient outcomes of VLP and IMN in distal radius fracture fixation. Three databases (Ovid MEDLINE, EMBASE, and Cochrane Library) were searched in July 2021. The inclusion criteria were RCTs comparing fixation of extra-articular or simple intra-articular distal radius with VLP or IMN and availability of full text in English. Children under the age of 18 were excluded. Seven trials with a total of 398 patients were included in this meta-analysis. The meta-analysis showed that there were improved short-term clinical outcomes favouring IMN, although there were no significant differences in terms of functional, radiological, and long-term clinical outcomes. Analysis showed that outcomes of IMN are comparable with VLP for fixation of extra-articular and simple intra-articular distal radius fractures. However, these results should be interpreted with caution due to the small sample size. We recommend that further high-quality trials are required to establish the role of IMN in distal radius fixation.


  • Open Access

    Disseminated intravascular coagulation following femoral nailing in a metastatic prostate carcinoma patient – A case report

    by Jeremy Wei Sern Lim, Wei Zhang, Derek Howard Park, Antony Xavier Rex Premchand


  • Intracerebral haemorrhage following spine surgery: a word of caution on the use of suction drains

    by Wei Zhang, Colum Patrick Nolan, Dinesh Shree Kumar, Reuben Chee Cheong Soh, Jacob Yoong-Leong Oh

    Intracranial haemorrhage (ICH) is a rare but devastating complication post spinal surgery. We present three cases of post spine surgery ICH that were associated with high drain outputs postoperatively. The first patient underwent C1–C6 instrumented fusion and C4–C6 decompression. 950 mls hemoserous fluid was drained via suction drain immediately postoperatively. He suffered cerebral hemorrhage with tonsillar herniation and was brain dead on the same night. The second patient underwent C1–T1 instrumented fusion with C3–C4 decompression. 400 mls hemoserous fluid was drained via suction drain shortly after skin closure. He suffered subdural hemorrhage, subarachnoid hemorrhage and intraventricular hemorrhage, with persistent neurologic deficits and required long-term institutionalised care. The third patient underwent L2–L4 decompression and instrumented fusion. 480 mls hemoserous fluid was drained via suction drain 2 hours postoperatively. He suffered subdural haemorrhage but eventually recovered fully. An excessive drain output, especially within first few minutes to hours postoperatively, may signify a CSFleak. Suction drains should be used with caution in these cases as negative suction in the presence of a dura tear increases risk of post spine surgery ICH. In these cases, the use of non-suction drains should be considered.


  • First Dorsal Metatarsal Artery Flap for Coverage of Distal Foot Wounds: A Case Discussion and Narrative Review

    by Wei Mbbs Zhang, Cheyenne K.P. Mbbs Rebosura, Pei Yein Mbbs Tong, Vaikunthan Mbbs Rajaratnam

    Reconstruction of distal foot and toe wounds present a challenging problem, as defects in this area are often associated with exposed tendons and bones, making split skin grafts impossible in many cases. There is also a need for any flap to achieve a smooth and nonbulky contour to allow for wearing of footwear and acceptable esthetic results. The first dorsal metatarsal artery (FDMA) flap has been increasingly described as a functional and effective method of managing relatively small distal foot and toe defects. We present a case study of our patient who underwent FDMA flap coverage of a big toe dorsum wound, and we also present a review of the literature. Of the 13 papers and 46 cases in the published literature, all flaps survived. Authors report good functional outcomes, with patients regaining ambulation and fitting footwear owing to the flap’s thin and pliable contour. Complications reported include 5 cases of superficial distal tip necrosis, all of which healed spontaneously. We conclude that the FDMA flap is a reliable, reproducible, and suitable coverage option for small distal foot, webspaces, and toe defects. They are relatively easy to perform and associated with good reported outcomes. Level of Evidence: Diagnostic Level V. See Instructions for Authors for a complete description of levels of evidence.


  • Risk factors for mechanical failure of intertrochanteric fractures after fixation with proximal femoral nail antirotation (PFNA II): a study in a Southeast Asian population

    by Wei Zhang, Rex Premchand Antony Xavier, Joshua Decruz, Ying Dong Chen, Derek Howard Park

    Introduction Intertrochanteric hip fractures pose a significant health problem. The proximal femur nail anti-rotation (PFNA IIDePuySynthes) is the most commonly used implant for intramedullary nailing of unstable intertrochanteric fractures at our institution. We aim to identify the risk factors predisposing to mechanical failure of intertrochanteric hip fractures fixation with PFNAII in our Southeast Asian population. Materials and methods We retrospectively reviewed 295 consecutive patients who underwent PFNA fixation for intertrochanteric fractures of the proximal femur between January 2014 and June 2018 at our institution. Exclusion criteria included a follow-up period of less than 4 months and patients with polytrauma. 204 patients were eligible for analysis, of which 22 had mechanical failure of PFNAII. We compared these patients with respect to their demographics, medical co-morbidities, quality of reduction according to the Baumgartner scale, calcar restoration, blade position according to Cleveland Zones, the stability of fracture according to OTA/AO classification, neck-shaft-angle, tip-apex distance, as well as neck of femur bone mineral density T-score. Patients were followed up for a minimum of 4 months and until fracture union or complication had occurred. Logistic regression analysis was performed to determine the odds ratio for mechanical failure for selected variables. Results Good quality of reduction reduced risk of mechanical failure whilst posterior blade position in lateral hip X-ray predicted it, with odds ratios of 0.147 (95% confidence interval, 0.030–0.733; p = 0.019) and12.12 (95% confidence interval, 1.583–92.825; p = 0.016) respectively. On univariate analysis, the mechanical failure group were older, had poorer calcar restoration, more unstable fracture patterns, more varus neck-shaft angle, and trochanteric starting points that were lateral to or on the tip of the greater trochanter. However, these were not significant in multivariate analysis. Tip apex distance, the severity of osteoporosis, presence of diabetes, chronic kidney disease and serum vitamin D levels were not significant predictors of failure. Conclusions To avoid mechanical failure, one should aim to achieve a good quality of reduction and centre blade position on lateral hip X-ray. Tip apex distance did not predict mechanical failure in our study.


  • Cephalomedullary blade cut-ins: a poorly understood phenomenon

    by Michael Yam, Benjamin Joseph Kang, Anuj Chawla, Wei Zhang, Law Gin Way, Rex Premchand Antony Xavier, Derek Howard Park, N. E. M. Yeo, T. S. Howe, E. B. K. Kwek

    Objectives Proximal femoral nail antirotation (PFNA) cut-in is a unique phenomenon seen in pertrochanteric hip fractures treated with the PFNA. Cut-in refers to the superomedial migration of the proximal femoral blade into the femoral head and hip joint. We recognize that cut-in is a completely separate entity from the well-described cut-out failure. This study assesses relevant radiological and patient risks factors for cut-in. Design Retrospective multicenter study looking at patients with pertrochanteric hip fractures managed with the Synthes PFNA Setting Four tertiary hospitals over 7 years. Patients Patients with cut-ins were identified. Outcome measurement The radiological appearance of this mode of failure was assessed and compared to cut-outs. Patient demographics, fracture configuration, time to implant failure (cut-in), bone mineral density, tip–apex distance, neck–shaft angle and position of the tip of the helical blade in the femoral head were collected. Results There was a total of 1027 patients across 4 institutions with 23 patients with cut-in. Average neck–shaft angle was 133 degrees. 16 out of 19 patients had severe osteoporosis with BMD < − 2.5. 14 of 23 patients had poor placement of the blade. 13 of 23 had a tip–apex distance of more than 20 mm. Conclusion We propose a standardized nomenclature of “cut-in” for the phenomenon of superomedial migration of the proximal femoral blade. An anatomical neck–shaft reduction, accurate blade placement and increased surveillance for patients with severe osteoporosis are required to reduce the incidence and morbidity of cut-in.