Yonghai Xu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Yonghai Xu has a total of 59 co-authors. Here are the top co-authors by number of shared publications:
Xiangning Xiao
4 shared publications- Jingjing Tu
School of Electrical & Electronic Engineering, North China Electric Power University, Beijing 102206, China
3 shared publications - Shun Tao
State Key Laboratory of Alternate Electrical Power System with Renewable Energy Sources North China Electric Power University Beijing China
3 shared publications - Zhongdong Yin
School of Electrical & Electronic Engineering, North China Electric Power University, Beijing 102206, China
3 shared publications - Abubakar Siddique
Department of Electrical & Biomedical Engineering, Khwaja Fareed University of Engineering & Information Technology (KFUEIT), Rahim Yar Khan 64200, Punjab, Pakistan
2 shared publications - Haiwei Jiang
State Grid Liaoning Economic Research Institute, Shenyang, China
2 shared publications
Latest Publications
- Open Access
A Method for Substation Operation Risk Situational Awareness Based on the Health State of Main Equipment
This paper proposes a substation operation risk situational awareness method based on the health state of the main equipment, with the goal of assessing the substation operation risk posture and performing risk prevention and control based on the situational awareness framework. Firstly, a risk propagation model considering the health state of the main equipment is proposed with reference to the SI (Susceptible–Infected) virus propagation model to simulate the risk propagation process among the main equipment of the substation; then, the potential risk severity index of the equipment is constructed based on the temporal set of risk propagation among the equipment within the substation to quantify the operational risk posture of the substation; finally, a case analysis is carried out by using a dual-voltage-level substation, and the results show that the method proposed in this paper can effectively simulate the risk propagation paths between the main equipment of a substation and the severity of the operational risk of each piece of main equipment. Based on the results of the substation operation risk situation assessment, it is used to guide the substation operation and inspection department to optimize the substation main equipment operation and inspection plan formulation, and to find the main equipment defects in time for overhaul and maintenance.
Open AccessA Method for Substation Operation Risk Situational Awareness Based on the Health State of Main Equipment
This paper proposes a substation operation risk situational awareness method based on the health state of the main equipment, with the goal of assessing the substation operation risk posture and performing risk prevention and control based on the situational awareness framework. Firstly, a risk propagation model considering the health state of the main equipment is proposed with reference to the SI (Susceptible–Infected) virus propagation model to simulate the risk propagation process among the main equipment of the substation; then, the potential risk severity index of the equipment is constructed based on the temporal set of risk propagation among the equipment within the substation to quantify the operational risk posture of the substation; finally, a case analysis is carried out by using a dual-voltage-level substation, and the results show that the method proposed in this paper can effectively simulate the risk propagation paths between the main equipment of a substation and the severity of the operational risk of each piece of main equipment. Based on the results of the substation operation risk situation assessment, it is used to guide the substation operation and inspection department to optimize the substation main equipment operation and inspection plan formulation, and to find the main equipment defects in time for overhaul and maintenance.
- 29 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 41 (3) , 1155-1168
Resonance Mitigation Effectiveness Evaluation and Damping Parameters Design Method for Parallel Resonance in Power System
Traditional methods evaluate and design resonance mitigation strategies by repeatedly solving system impedance, which results in low efficiency, limited scalability. There is a lack of universal and effective evaluation approaches to analyze the effectiveness of strategies for local/non-local resonances of multiple nodes and harmonic current amplifications in multiple resonance-participating branches. To address this issue, a parallel resonance mitigation domain (PRMD)-based effectiveness evaluation method for resonance mitigation strategies is proposed. By decoupling the strategies' equivalent impedance from the nodal impedance matrix, the method avoids repeated system matrix inversion, simplifying the evaluation process significantly. The relative mitigation domain (RMD) and ideal mitigation domain (IMD) for each domain of PRMD are further defined to guide optimal parameter selection. Based on this, a damping parameters design method based on IMD-PRMD is proposed to streamline the decision-making process and achieve comprehensive parallel resonance mitigation. The proposed method can be extended to any resonance scenario.
- 29 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 41 (3) , 1155-1168
Resonance Mitigation Effectiveness Evaluation and Damping Parameters Design Method for Parallel Resonance in Power System
Traditional methods evaluate and design resonance mitigation strategies by repeatedly solving system impedance, which results in low efficiency, limited scalability. There is a lack of universal and effective evaluation approaches to analyze the effectiveness of strategies for local/non-local resonances of multiple nodes and harmonic current amplifications in multiple resonance-participating branches. To address this issue, a parallel resonance mitigation domain (PRMD)-based effectiveness evaluation method for resonance mitigation strategies is proposed. By decoupling the strategies' equivalent impedance from the nodal impedance matrix, the method avoids repeated system matrix inversion, simplifying the evaluation process significantly. The relative mitigation domain (RMD) and ideal mitigation domain (IMD) for each domain of PRMD are further defined to guide optimal parameter selection. Based on this, a damping parameters design method based on IMD-PRMD is proposed to streamline the decision-making process and achieve comprehensive parallel resonance mitigation. The proposed method can be extended to any resonance scenario.
- Open Access
- 9 December 2025
- Published by MDPI AG in Preprints.org
A Method for Substation Operation Risk Situational Awareness Based on the Health State of Main Equipment
This paper proposes a substation operation risk situational awareness method based on the health state of main equipment, with the objective of assessing the substation operation risk posture and performing risk prevention and control based on the situational awareness model. Firstly, the time-varying failure rate corresponding to the risk propagation moment of the main equipment of the substation is obtained based on the equipment failure rate model considering the effect of equipment deterioration; Secondly, the risk propagation model considering the health state of the main equipment is proposed with reference to the SI virus transmission model to simulate the risk propagation process among the main equipment of the substation; Then, the construction of equipment potential risk severity index to realize the substation operation risk posture presentation; Finally, based on the results of the substation operation risk situation assessment, the main equipment operation and inspection plan is optimized to formulate the main equipment operation and inspection plan, and the defects of the main equipment are found in time to carry out overhauling and maintenance. The example analysis is carried out using a dual-voltage level substation, and the results show that the method proposed in this paper can effectively analyse the substation operation risk situation.
- 9 December 2025
- Published by MDPI AG in Preprints.org
Open AccessA Method for Substation Operation Risk Situational Awareness Based on the Health State of Main Equipment
This paper proposes a substation operation risk situational awareness method based on the health state of main equipment, with the objective of assessing the substation operation risk posture and performing risk prevention and control based on the situational awareness model. Firstly, the time-varying failure rate corresponding to the risk propagation moment of the main equipment of the substation is obtained based on the equipment failure rate model considering the effect of equipment deterioration; Secondly, the risk propagation model considering the health state of the main equipment is proposed with reference to the SI virus transmission model to simulate the risk propagation process among the main equipment of the substation; Then, the construction of equipment potential risk severity index to realize the substation operation risk posture presentation; Finally, based on the results of the substation operation risk situation assessment, the main equipment operation and inspection plan is optimized to formulate the main equipment operation and inspection plan, and the defects of the main equipment are found in time to carry out overhauling and maintenance. The example analysis is carried out using a dual-voltage level substation, and the results show that the method proposed in this paper can effectively analyse the substation operation risk situation.
- 28 November 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 47, 1-5
Economic Analysis of High Penetration of Renewable Energy under Market Environment
The proportion of renewable energy is gradually increasing with the requirement for carbon reduction in the energy sector. In the situation of high proportion of renewable energy integrated into power systems, the traditional market mechanism dominated by thermal power units may no longer be suitable. This paper simulates the results of LMPs calculated by the economic dispatch model when the installed capacity of renewable energy is high and analyzes the unreasonable results. In addition, this paper proposes to modify the cost function of renewable energy units to linear function. Based on it, the traditional economic dispatch model is thereafter modified to attach the carbon emission cost to the objective function of the market clearing model. Finally, this paper simulates the problem of optimal location selection for renewable energy installations to demonstrate the effectiveness of the proposed updated economic dispatch model.
- 28 November 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 47, 1-5
Economic Analysis of High Penetration of Renewable Energy under Market Environment
The proportion of renewable energy is gradually increasing with the requirement for carbon reduction in the energy sector. In the situation of high proportion of renewable energy integrated into power systems, the traditional market mechanism dominated by thermal power units may no longer be suitable. This paper simulates the results of LMPs calculated by the economic dispatch model when the installed capacity of renewable energy is high and analyzes the unreasonable results. In addition, this paper proposes to modify the cost function of renewable energy units to linear function. Based on it, the traditional economic dispatch model is thereafter modified to attach the carbon emission cost to the objective function of the market clearing model. Finally, this paper simulates the problem of optimal location selection for renewable energy installations to demonstrate the effectiveness of the proposed updated economic dispatch model.
- Open Access
- 1 August 2023
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 2564 (1) , 012040
Large-signal Stability Analysis of Grid-connected DC Microgrid with VSC
The grid-connected DC microgrid under the background of high penetrations of renewable energy sources and high penetrations of inverter-interfaced devices has the characteristics of strong nonlinearity and poor immunity, which leads to the problems of large-scale voltage fluctuation and instability when the grid-connected DC microgrid suffers large disturbances, and it seriously influences the security and stable operation of the system. Therefore, a large disturbance stability criterion which is based on the mixed potential theory (MPT) for the DC microgrid model with a grid-connected voltage-source converter (VSC) is proposed. This paper also analyzes the mechanism of the conservatism of the stability criterion, verifies the accuracy of the large disturbance stability standard, and analyses the influencing elements and basic mechanism of the large-signal stability (LSS) of the nonlinear systems, which provides a benchmark to design the parameters of the control of VSC and main circuit. Finally, the effectiveness and accuracy of the analysis are verified by electromagnetic transient simulation.
- 1 August 2023
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 2564 (1) , 012040
Open AccessLarge-signal Stability Analysis of Grid-connected DC Microgrid with VSC
The grid-connected DC microgrid under the background of high penetrations of renewable energy sources and high penetrations of inverter-interfaced devices has the characteristics of strong nonlinearity and poor immunity, which leads to the problems of large-scale voltage fluctuation and instability when the grid-connected DC microgrid suffers large disturbances, and it seriously influences the security and stable operation of the system. Therefore, a large disturbance stability criterion which is based on the mixed potential theory (MPT) for the DC microgrid model with a grid-connected voltage-source converter (VSC) is proposed. This paper also analyzes the mechanism of the conservatism of the stability criterion, verifies the accuracy of the large disturbance stability standard, and analyses the influencing elements and basic mechanism of the large-signal stability (LSS) of the nonlinear systems, which provides a benchmark to design the parameters of the control of VSC and main circuit. Finally, the effectiveness and accuracy of the analysis are verified by electromagnetic transient simulation.
- Open Access
- 25 July 2023
- Published by Wiley
Coordinated Planning Method Considering Flexible Resources of Active Distribution Network and Soft Open Point Integrated with Energy Storage System
Faced with the uncertainty of wind and photovoltaic power output and load fluctuation caused by the increase of new energy penetration in active distribution network, the demand for operational flexibility and the construction demand for flexible resources of distribution network are gradually increasing. The flexible operation of active distribution network can be realized by coordinated planning of the soft open point integrated with energy storage system (ESOP) and flexible resources. Firstly, the flexibility resource adjustability evaluation and margin indicators are proposed for the response model of typical flexibility resources. Secondly, a two-stage distributionally robust coordinated planning model considering the coordination planning scheme of distributed generation, flexibility resource and ESOP as well as the comprehensive norm uncertainty of wind power and photovoltaic outputs multi-operation scenarios is established with the distribution network construction cost, annual operation cost and annual power sales revenue as the objective functions meanwhile the investment and flexibility resource operation as constraints. Finally, the column constraint generation algorithm is used to solve the problem, and the effectiveness of the proposed model is verified by the modified IEEE33 node system.
- 25 July 2023
- Published by Wiley
Open AccessCoordinated Planning Method Considering Flexible Resources of Active Distribution Network and Soft Open Point Integrated with Energy Storage System
Faced with the uncertainty of wind and photovoltaic power output and load fluctuation caused by the increase of new energy penetration in active distribution network, the demand for operational flexibility and the construction demand for flexible resources of distribution network are gradually increasing. The flexible operation of active distribution network can be realized by coordinated planning of the soft open point integrated with energy storage system (ESOP) and flexible resources. Firstly, the flexibility resource adjustability evaluation and margin indicators are proposed for the response model of typical flexibility resources. Secondly, a two-stage distributionally robust coordinated planning model considering the coordination planning scheme of distributed generation, flexibility resource and ESOP as well as the comprehensive norm uncertainty of wind power and photovoltaic outputs multi-operation scenarios is established with the distribution network construction cost, annual operation cost and annual power sales revenue as the objective functions meanwhile the investment and flexibility resource operation as constraints. Finally, the column constraint generation algorithm is used to solve the problem, and the effectiveness of the proposed model is verified by the modified IEEE33 node system.
- Open Access
A Voltage Sag Severity Evaluation Method for the System Side Which Considers the Influence of the Voltage Tolerance Curve and Sag Type
Considering the influence of user equipment voltage tolerance characteristics and sag types on the evaluation results, this paper proposes a voltage sag severity evaluation method for the system side which considers the influence of the voltage tolerance curve and sag type. As such, a quantitative evaluation of the severity of voltage sag events can be achieved. Firstly, the user’s voltage tolerance curve is used to construct the comparison reference value of the energy index, in order to realize the rapid analysis of the severity of the sag event in the normal area and the abnormal area. Secondly, aiming at the problem of insufficient descriptions of the severity difference of sag events in uncertain areas, an improved energy index evaluation model combined with user tolerance characteristics is established through an interval division and interval weight calculation, so as to divide and evaluate the severity of sag events in uncertain areas. Considering the influence of the sag type on the voltage tolerance curve and user equipment, the energy index correction factor is then constructed, and the measurement function is used for an interval evaluation to obtain the ranking result of the voltage sag severity, which is more in line with the actual situation. Finally, the rationality and effectiveness of the proposed method are verified by analyzing 24 voltage sag events at a monitoring node.
Open AccessA Voltage Sag Severity Evaluation Method for the System Side Which Considers the Influence of the Voltage Tolerance Curve and Sag Type
Considering the influence of user equipment voltage tolerance characteristics and sag types on the evaluation results, this paper proposes a voltage sag severity evaluation method for the system side which considers the influence of the voltage tolerance curve and sag type. As such, a quantitative evaluation of the severity of voltage sag events can be achieved. Firstly, the user’s voltage tolerance curve is used to construct the comparison reference value of the energy index, in order to realize the rapid analysis of the severity of the sag event in the normal area and the abnormal area. Secondly, aiming at the problem of insufficient descriptions of the severity difference of sag events in uncertain areas, an improved energy index evaluation model combined with user tolerance characteristics is established through an interval division and interval weight calculation, so as to divide and evaluate the severity of sag events in uncertain areas. Considering the influence of the sag type on the voltage tolerance curve and user equipment, the energy index correction factor is then constructed, and the measurement function is used for an interval evaluation to obtain the ranking result of the voltage sag severity, which is more in line with the actual situation. Finally, the rationality and effectiveness of the proposed method are verified by analyzing 24 voltage sag events at a monitoring node.
- Open Access
- 2 April 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 9, 52860-52871
The Generation Mechanism and Elimination Strategy of Narrow- and Error-Pulse for Cascaded H-Bridge NL-PWM Modulation
There is a wide application prospect of Nearest level pulse width modulation (NL-PWM) in cascaded H-bridge (CHB) converter, however, it will produce narrow- and error-pulse in the process of implementation, which has a negative impact on CHB efficiency, output voltage quality and safe operation of power devices. In this paper, the NL-PWM strategy is improved based on round function to solve the narrow pulse of traditional NL-PWM, and a step wave delay update strategy is proposed to solve the error-pulse of NL-PWM. This paper analyzes the basic principle of improved NL-PWM and its ability to avoid narrow pulse of power device, shows the harmonic characteristics of improved NL-PWM, analyzes the generation mechanism of error pulse, and calculates the error of output voltage caused by the proposed step wave delay update strategy. The correctness of theoretical analysis and the effectiveness of the proposed method are verified by simulation and experiment. The research shows that the improved NL-PWM can effectively prevent narrow pulse while maintaining good harmonic characteristics, and the proposed step wave delay update strategy can avoid error pulse and has little impact on the output of NL-PWM.
- 2 April 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 9, 52860-52871
Open AccessThe Generation Mechanism and Elimination Strategy of Narrow- and Error-Pulse for Cascaded H-Bridge NL-PWM Modulation
There is a wide application prospect of Nearest level pulse width modulation (NL-PWM) in cascaded H-bridge (CHB) converter, however, it will produce narrow- and error-pulse in the process of implementation, which has a negative impact on CHB efficiency, output voltage quality and safe operation of power devices. In this paper, the NL-PWM strategy is improved based on round function to solve the narrow pulse of traditional NL-PWM, and a step wave delay update strategy is proposed to solve the error-pulse of NL-PWM. This paper analyzes the basic principle of improved NL-PWM and its ability to avoid narrow pulse of power device, shows the harmonic characteristics of improved NL-PWM, analyzes the generation mechanism of error pulse, and calculates the error of output voltage caused by the proposed step wave delay update strategy. The correctness of theoretical analysis and the effectiveness of the proposed method are verified by simulation and experiment. The research shows that the improved NL-PWM can effectively prevent narrow pulse while maintaining good harmonic characteristics, and the proposed step wave delay update strategy can avoid error pulse and has little impact on the output of NL-PWM.
- 16 February 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 37 (1) , 279-289
A Unified Method of Frequency Oscillation Characteristic Analysis for Multi-VSG Grid-Connected System
This paper addresses the frequency oscillation problem in a parallel-inverter-based grid-connected system. Angular frequency interactions between inverters and the grid exhibit various numbers of complicated characteristics that seriously threaten the connected power system's stable operation. This paper proposes a unified frequency oscillation method analysis to investigate the oscillation problem in a multi-VSG grid-connected system. In this method, the power control model of each grid-connected inverter is equivalent to a two-terminal network by analogy method, which can be described as a “current source” connected in parallel with a reciprocal of “admittance” and then joined in series with a joint of “admittance.” Next, considering the influence of grid impedance, the model of the whole grid-connected system is established to reveal the mechanism of multi-VSG angular frequency oscillation. Subsequently, the influence factors of frequency oscillation and its variation law are analyzed through transfer functions, which provide an essential theoretical method for solving the frequency oscillation problem in the current multi-inverter grid-connected engineering application. Finally, we validate the effectiveness and correctness of the small-signal model and the frequency oscillation characteristics by building the MATLAB/Simulink simulation.
- 16 February 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 37 (1) , 279-289
A Unified Method of Frequency Oscillation Characteristic Analysis for Multi-VSG Grid-Connected System
This paper addresses the frequency oscillation problem in a parallel-inverter-based grid-connected system. Angular frequency interactions between inverters and the grid exhibit various numbers of complicated characteristics that seriously threaten the connected power system's stable operation. This paper proposes a unified frequency oscillation method analysis to investigate the oscillation problem in a multi-VSG grid-connected system. In this method, the power control model of each grid-connected inverter is equivalent to a two-terminal network by analogy method, which can be described as a “current source” connected in parallel with a reciprocal of “admittance” and then joined in series with a joint of “admittance.” Next, considering the influence of grid impedance, the model of the whole grid-connected system is established to reveal the mechanism of multi-VSG angular frequency oscillation. Subsequently, the influence factors of frequency oscillation and its variation law are analyzed through transfer functions, which provide an essential theoretical method for solving the frequency oscillation problem in the current multi-inverter grid-connected engineering application. Finally, we validate the effectiveness and correctness of the small-signal model and the frequency oscillation characteristics by building the MATLAB/Simulink simulation.