STShun Tao

Shun Tao

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Shun Tao has a total of 37 co-authors. Here are the top co-authors by number of shared publications:

  • Yonghai Xu

    State Key Laboratory of Alternate Electrical Power System With Renewable Energy Sources North China Electric Power University Changping Beijing China

    4 shared publications
  • Yonghai Xu

    School of Electrical and Electronic Engineering, North China Electric Power University, Beijing 102206, China

    3 shared publications
  • Shaobo Xu

    Power Dispatch and Control Centre State Grid Shanxi Electric Power Co., Ltd Taiyuan China

    2 shared publications
  • Xinyi Zhu

    State Key Laboratory of Alternate Electrical Power System with Renewable Energy Sources, North China Electric Power University, Beijing, China

    2 shared publications
  • Yonghai Xu

    School of Electrical and Electronic Engineering, North China Electric Power University, Beijing 102206, China

    2 shared publications
  • Zheheng Xu

    State Key Laboratory of Alternate Electrical Power System with Renewable Energy Sources North China Electric Power University Beijing China

    2 shared publications

Latest Publications

  • Resonance Mitigation Effectiveness Evaluation and Damping Parameters Design Method for Parallel Resonance in Power System

    by Bingwen Guo, Yonghai Xu, Chang Yuan, Shun Tao

    Traditional methods evaluate and design resonance mitigation strategies by repeatedly solving system impedance, which results in low efficiency, limited scalability. There is a lack of universal and effective evaluation approaches to analyze the effectiveness of strategies for local/non-local resonances of multiple nodes and harmonic current amplifications in multiple resonance-participating branches. To address this issue, a parallel resonance mitigation domain (PRMD)-based effectiveness evaluation method for resonance mitigation strategies is proposed. By decoupling the strategies' equivalent impedance from the nodal impedance matrix, the method avoids repeated system matrix inversion, simplifying the evaluation process significantly. The relative mitigation domain (RMD) and ideal mitigation domain (IMD) for each domain of PRMD are further defined to guide optimal parameter selection. Based on this, a damping parameters design method based on IMD-PRMD is proposed to streamline the decision-making process and achieve comprehensive parallel resonance mitigation. The proposed method can be extended to any resonance scenario.

  • Open Access

    Voltage Source Converter Harmonic Model Considering Frequency Coupling Effects for Harmonic Load Flow Study

    by Zheheng Xu, Shun Tao, Shuo Yang, Shaobo Xu, Yonghai Xu

    Voltage source converters (VSCs) are widely used in distribution grids. Their complex wideband harmonic responses, arising from frequency coupling (FC) effects, complicate harmonic load flow (HLF) analysis and are prone to amplification due to system resonance. To address these challenges, this paper develops an efficient and accurate frequency‐coupling admittance matrix (FCAM) harmonic model for a typical VSC. First, the FC phenomena caused by asymmetry in dq ‑axis control as well as by analogue/digital sampling and pulse width modulation sideband effects are analysed, and their combined influence on transfer paths of coupled harmonics is investigated. Then, the coupling spectrum is pre‐truncated based on physical mechanisms. This yields eight key coupled harmonic components and a compact FCAM model with a small matrix size and clear physical interpretability. Using this model, a non‑iterative multi‑frequency‑coupled HLF calculation method is proposed, improving the computational efficiency and stability. Finally, the accuracy of both the VSC harmonic model and HLF calculation method is validated through hardware‑in‑the‑loop simulations and electromagnetic transient simulations, respectively. Additionally, the model is applied to a modified IEEE 33‑bus test system for HLF study, and the frequency bands most sensitively affected by FC effects are identified.

  • Open Access

    Quasi‐Steady‐State Instantaneous Power Flows in VSC Grid‐Connected System: Definition, Mechanism and Optimisation

    by Yuhang Guan, Shun Tao, Tong Guo, Yonghai Xu

    With voltage source converters (VSCs) being widely integrated into the power‐electronised power system, their quasi‐steady‐state instantaneous power flows (QSS‐IPFs) under harmonic emissions and resonance risks have become an important power quality concern. However, research on QSS‐IPFs in VSC grid‐connected systems still lacks an integrated analytical path linking indicator definition, mechanism characterisation and device‐level optimisation. Therefore, this article conducts research along this path. A QSS‐IPF indicator framework and its hardware‐in‐the‐loop self‐consistency validation are introduced, with the indicators partitioned according to the system resonance characteristics and topological property. The generation and conversion mechanisms of constant, pulsating, and oscillatory components of QSS‐IPFs within the VSC are investigated, with the geometric algebra channel‐energy formalism applied to the VSC switching‐function model to provide the analytical basis. Based on the instantaneous power oscillation energy (IPOE) and its quantified transmission characteristics of QSS‐IPFs, a PSO‐based LCL filter optimisation method with its optimisation objective built on the IPOE is proposed. Together with the QSS‐IPF indicator block derived from the existing harmonic coupled source model, this method supports the optimisation analysis of grid‐connected QSS‐IPF pollution.

  • Open Access

    A Mechanism–Data Hybrid‐Driven Dynamic Coupling Model for Grid‐Connected Harmonic Sources in Renewable Energy Systems

    by Ziyu Wang, Shun Tao, Zheheng Xu

    The large‐scale grid integration of renewable energy sources, such as wind and photovoltaic generation, relies on power electronic converters, whose nonlinear and time‐varying characteristics introduce severe harmonic pollution and threaten power quality and grid stability. Accurate harmonic source modelling is essential for harmonic assessment, localisation, and mitigation. However, traditional static mechanism‐based models are unable to accurately capture dynamic coupling between harmonic voltages and currents, while purely data‐driven models suffer from limited interpretability and high data requirements. To address these issues, this paper proposes a mechanism–data hybrid‐driven dynamic coupling model for harmonic sources. First, a harmonic coupling admittance matrix is established from a mechanism‐based perspective, and a variable forgetting factor recursive least squares (VFF‐RLS) algorithm is applied for online dynamic identification to adapt to operating condition variations. Subsequently, a data‐driven model integrating LSTM and an iTransformer enhanced with differential multi‐head attention is proposed to capture nonlinear dynamics and stochastic disturbances that are inadequately represented by the mechanism model. Experimental validation using measured wind and photovoltaic data demonstrates that the proposed model achieves high accuracy and stability across different harmonic orders, effectively characterising dynamic cross‐frequency coupling between harmonic currents and harmonic voltages.

  • Modeling of Coupled Harmonic Current Source for Grid-Connected Inverters

    by Shun Tao, Xinyi Zhu, Shaobo Xu, Yonghai Xu

    Power systems are entering the era of high proportions of new energy and power electronic equipment. The interaction between grid background harmonics and grid-connected inverters (GCIs) leads to frequency coupling effect, which results in additional frequency components injecting into the power networks. However, there is limited research on the modeling of harmonic sources based on the frequency coupling effects. Hence, this article, first, analyzes the harmonic response and emission mechanisms of frequency coupling effect caused by dq -axis asymmetric control of GCIs. Then, the transmission process of harmonic components in sampling delay progress, outer loop, inner loop, phase-locked loop, signal modulation module, and filter of the inverter is deduced. Voltage-controlled coupled harmonic current source models are established considering the frequency coupling effect, suitable for harmonic/interharmonic power flow studies of public supply networks. The proposed models are verified by time-domain simulations under different single harmonic and by hardware-in-the-loop simulations under multiple harmonics. Finally, the impacts of the outer loop, inner loop, phase-locked loop and output power, and the characteristics of harmonic admittance are analyzed.


  • Open Access

    DC Active Damper Control Strategy Based on Resonance Suppression Effectiveness Evaluation Method

    by Huaying Zhang, Yingxin Wang, Xinyi Zhu, Yonghai Xu, Shun Tao

    With the complication of the power system, features of the resonance interaction behave diversely and pose a threat to the effectiveness of the resonance suppression strategies. Existing resonance suppression strategies are usually designed for specific scenarios which are in close correlation with the impedance frequency-amplitude distribution, and their adaptability under different scenarios is hard to evaluate. In this paper, the resonance suppression domain of a DC distribution network is derived based on the node impedance variation before/after the resonance is suppressed. The derived criterion takes the admittance change of the resonance suppression strategies as variables, and the conservative/ideal suppression domain criteria are defined. On this basis, a method for evaluating the effectiveness of resonance suppression strategies is proposed, which simplifies the evaluation process and avoids a complicated matrix inverse process to each resonance suppression strategy during the system impedance calculation. Furthermore, a DC active damper control strategy based on the resonance suppression strategy evaluation is proposed, and the proposed strategy could suppress resonances under different scenarios by a targeted design of the reshaping admittance parameters. Time domain simulations with a 5-node distribution network are carried out to verify the proposed method.


  • Open Access

    Multi-Inverter Resonance Modal Analysis Based on Decomposed Conductance Model

    by Lin Chen, Yonghai Xu, Shun Tao, Tianze Wang, Shuguang Sun

    The Norton equivalent model based on the transfer function and the frequency domain analysis method for inverter resonance analysis lacks a comprehensive analysis of the resonant characteristics, and more information about the resonant key components and the degree of participation cannot be obtained. In this paper, a decomposed conductance model is proposed to characterize the resonance characteristics of the multi-inverter grid-connected system and the effect of the equivalent control link of the inverter on the resonance in more detail by combining the modal analysis method and the sensitivity analysis method. Firstly, based on αβ coordinates, the conductance division is carried out for the dual-loop inverter control link with the voltage external loop and current internal loop using capacitor-current feedback damping, and the inverter model based on the decomposition conductance is derived. The mathematical model of the multi-inverter grid-connected system is then established. Secondly, the resonance characteristics of the system are analyzed by combining the modal and frequency domain analysis methods when the number of inverters, inverter parameters, and grid-side impedance are changed. Thirdly, the degree of involvement of the system components, especially the equivalent control link of the inverter in resonance conditions, is determined in combination with the proposed model and the sensitivity analysis method, which is the basis for proposing an effective suppression strategy. Finally, a simulation model is built to verify the proposed method and the analysis results.