Yen-Chun Chen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Yen-Chun Chen has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
- Thomas Justus Schmidt
PSI Center for Energy and Environmental Sciences, Paul Scherrer Institute, Villigen, Switzerland
4 shared publications - Felix Büchi
Electrochemistry Laboratory, Paul Scherrer Institut, 5232 Villigen PSI, Switzerland
3 shared publications Anne Berger
Chair of Technical Electrochemistry, Department of Chemistry and Catalysis Research Center, Technical University of Munich, D-85748 Garching, Germany
2 shared publications- Jens Eller
Paul Scherrer Institut
2 shared publications - Anne Berger
Technical University of Munich; TUM School of Natural Sciences, Department of Chemistry and Catalysis Research Center, Chair of Technical Electrochemistry, Garching, Germany
1 shared publication - Christoph Csoklich
Paul Scherrer Institut, Forschungsstrasse 111, 5232 Villigen, Switzerland
1 shared publication
Latest Publications
- Open Access
- 1 September 2023
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 170 (9) , 094509
Analysis of the MPL/GDL Interface: Impact of MPL Intrusion into the GDL Substrate
Interfaces are crucial for the water management in polymer electrolyte membrane fuel cells (PEMFCs). The introduction of a microporous layer (MPL) had a revolutionary effect on the water distribution by improving the interface between the catalyst layer and the gas diffusion layer substrate (GDL-S). Hence, it is vital to maximize the improvement by further characterizing and advancing the properties of the interfaces, in this case the MPL/GDL-S interface. This study aims at fabricating a GDL with an MPL that intrudes into the GDL-S, analyzing the impact on the GDL-S structure and on PEMFC performance. Mercury intrusion porosimetry (MIP) and ex situ X-ray tomography (XTM) show that the intrusion of the MPL into the hydrophobic GDL-S proceeds via the preferential filling of the GDL-S macropores, thereby reducing their size and volume fraction in the GDL-S. While an intruding MPL leads to a small performance increase under wet PEMFC operating conditions, this improvement could only be achieved by a careful management between the extent of MPL intrusion and the partial macropore blocking in the GDL-S. Furthermore, the impact of MPL intrusion on the liquid water saturation of the GDL was quantified by operando XTM. The results provide design guidelines for improved GDLs.
- 1 September 2023
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 170 (9) , 094509
Open AccessAnalysis of the MPL/GDL Interface: Impact of MPL Intrusion into the GDL Substrate
Interfaces are crucial for the water management in polymer electrolyte membrane fuel cells (PEMFCs). The introduction of a microporous layer (MPL) had a revolutionary effect on the water distribution by improving the interface between the catalyst layer and the gas diffusion layer substrate (GDL-S). Hence, it is vital to maximize the improvement by further characterizing and advancing the properties of the interfaces, in this case the MPL/GDL-S interface. This study aims at fabricating a GDL with an MPL that intrudes into the GDL-S, analyzing the impact on the GDL-S structure and on PEMFC performance. Mercury intrusion porosimetry (MIP) and ex situ X-ray tomography (XTM) show that the intrusion of the MPL into the hydrophobic GDL-S proceeds via the preferential filling of the GDL-S macropores, thereby reducing their size and volume fraction in the GDL-S. While an intruding MPL leads to a small performance increase under wet PEMFC operating conditions, this improvement could only be achieved by a careful management between the extent of MPL intrusion and the partial macropore blocking in the GDL-S. Furthermore, the impact of MPL intrusion on the liquid water saturation of the GDL was quantified by operando XTM. The results provide design guidelines for improved GDLs.
- Open Access
- 31 July 2023
- Published by Royal Society of Chemistry (RSC) in Energy Advances
- Vol. 2 (9) , 1447-1463
On the water transport mechanism through the microporous layers of operando polymer electrolyte fuel cells probed directly by X-ray tomographic microscopy
Product water transport via the microporous layer (MPL) and gas diffusion layer (GDL) substrate during polymer electrolyte fuel cell (PEFC) operation was directly and quantitatively observed by X-ray tomographic microscopy (XTM). The liquid water distribution in two types of MPLs with different pore size distributions (PSDs) was characterized as a function of the inlet gas relative humidity (RH) and current density under humid operating conditions at 45 °C. During the first minute of PEFC operation, liquid water mainly accumulated at the catalyst layer (CL)/MPL interface and in the GDL substrate close to the flow fields. Furthermore, under all tested conditions, saturation in the MPL was low (ca. 70%. Based on these XTM results, it is confirmed that in the high porosity MPLs, vapor transport was non-negligible even at high humidity conditions. Therefore, on top of the widely discussed MPL pore size and its distribution, it is proposed that the lower thermal conductivity from the high porosity of MPLs can also be a main cause of promoted vapor transport, reducing water saturation near the CL.
- 31 July 2023
- Published by Royal Society of Chemistry (RSC) in Energy Advances
- Vol. 2 (9) , 1447-1463
Open AccessOn the water transport mechanism through the microporous layers of operando polymer electrolyte fuel cells probed directly by X-ray tomographic microscopy
Product water transport via the microporous layer (MPL) and gas diffusion layer (GDL) substrate during polymer electrolyte fuel cell (PEFC) operation was directly and quantitatively observed by X-ray tomographic microscopy (XTM). The liquid water distribution in two types of MPLs with different pore size distributions (PSDs) was characterized as a function of the inlet gas relative humidity (RH) and current density under humid operating conditions at 45 °C. During the first minute of PEFC operation, liquid water mainly accumulated at the catalyst layer (CL)/MPL interface and in the GDL substrate close to the flow fields. Furthermore, under all tested conditions, saturation in the MPL was low (ca. 70%. Based on these XTM results, it is confirmed that in the high porosity MPLs, vapor transport was non-negligible even at high humidity conditions. Therefore, on top of the widely discussed MPL pore size and its distribution, it is proposed that the lower thermal conductivity from the high porosity of MPLs can also be a main cause of promoted vapor transport, reducing water saturation near the CL.
- Open Access
- 13 July 2022
- Published by Royal Society of Chemistry (RSC) in Chemical Communications
- Vol. 58 (63) , 8854-8857
On the role of pore constrictions in gas diffusion electrodes
A descriptor for the characteristic size of constrictions is introduced to evaluate the water saturation properties of gas diffusion electrodes.
- 13 July 2022
- Published by Royal Society of Chemistry (RSC) in Chemical Communications
- Vol. 58 (63) , 8854-8857
Open AccessOn the role of pore constrictions in gas diffusion electrodes
A descriptor for the characteristic size of constrictions is introduced to evaluate the water saturation properties of gas diffusion electrodes.
- Open Access
- 20 May 2022
- Published by Elsevier in Journal of Power Sources
- Vol. 539
Determination of the porosity and its heterogeneity of fuel cell microporous layers by X-ray tomographic microscopy
- 20 May 2022
- Published by Elsevier in Journal of Power Sources
- Vol. 539
Open AccessDetermination of the porosity and its heterogeneity of fuel cell microporous layers by X-ray tomographic microscopy
- Open Access
- 4 January 2020
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 167 (6) , 064516
Impact of the Microporous Layer on Gas Diffusion Layers with Patterned Wettability I: Material Design and Characterization
Gas diffusion media is one of the main components affecting the water management in polymer electrolyte fuel cells, which is key for a high and stable performance. Building up on our previously designed gas diffusion layers (GDLs) with patterned wettability, we included in this study customized microporous layers (MPLs) with the target to enhance the effect of hydrophilic water pathways and reduce mass transport losses. The MPLs were modified by introducing “weak points” using electron induced radiation grafting or local mechanical perforation, in order to canalize the water injection to the hydrophilic pattern of the GDL. We describe the techniques used for gas diffusion media modification, their limitations and their influence on water distribution. We also study in detail the impact of different water injection methods on water distribution, in particular comparing capillary pressure water injection to electrochemical water production. The important differences observed between these two methods, were attributed to the absence of hydraulic connection between the water injection points in the latter case. Although the ex situ characterization shows that the local MPL modifications were successful, the targeted canalization of water injection was not observed, calling for future MPL modifications with an improved lateral transport.
- 4 January 2020
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 167 (6) , 064516
Open AccessImpact of the Microporous Layer on Gas Diffusion Layers with Patterned Wettability I: Material Design and Characterization
Gas diffusion media is one of the main components affecting the water management in polymer electrolyte fuel cells, which is key for a high and stable performance. Building up on our previously designed gas diffusion layers (GDLs) with patterned wettability, we included in this study customized microporous layers (MPLs) with the target to enhance the effect of hydrophilic water pathways and reduce mass transport losses. The MPLs were modified by introducing “weak points” using electron induced radiation grafting or local mechanical perforation, in order to canalize the water injection to the hydrophilic pattern of the GDL. We describe the techniques used for gas diffusion media modification, their limitations and their influence on water distribution. We also study in detail the impact of different water injection methods on water distribution, in particular comparing capillary pressure water injection to electrochemical water production. The important differences observed between these two methods, were attributed to the absence of hydraulic connection between the water injection points in the latter case. Although the ex situ characterization shows that the local MPL modifications were successful, the targeted canalization of water injection was not observed, calling for future MPL modifications with an improved lateral transport.