Dawit Lee
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Dawit Lee has a total of 39 co-authors. Here are the top co-authors by number of shared publications:
- Aaron J. Young
Georgia Institute of Technology
11 shared publications - Inseung Kang
Department of Mechanical Engineering, Carnegie Mellon University, Pittsburgh, PA, USA
5 shared publications - Kinsey R. Herrin
Georgia Institute of Technology
4 shared publications - Bailey J. McLain
Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology, Atlanta, USA
3 shared publications - Sierra C. Mulrine
Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology , 313 Ferst Dr NW, Atlanta, GA 30332
3 shared publications - Dongho Park
School of Mechanical Engineering, Georgia Institute of Technology, Atlanta, GA, USA
2 shared publications
Latest Publications
- Open Access
StaBLE: digital metrics capture balance performance across a wide spectrum of balance tasks and abilities
Balance is fundamental to mobility and independence, yet it remains difficult to measure in a way that is both clinically meaningful and feasible for widespread adoption. There is a need for more quantitative, objective, and accessible balance assessments. To this end, we created the Stanford Balance Level Evaluation (StaBLE), a battery of 18 balance-challenging tasks and accompanying digital performance metrics computed from video that aimed to capture widely ranging balance abilities across 180 participants. We validated the StaBLE score against existing clinical scales and found that it correlated with age (ρ = -0.76, p<0.001), the Activities-Specific Balance Confidence Scale (ρ = 0.60, p<0.001), a Mini-Balance Evaluation Systems Test task (τ=0.55, p<0.001), 4-Stage Balance Test (τ = 0.55, p<0.001), and Short Physical Performance Battery (τ =0.57, p<0.001). StaBLE overcame ceiling effects in these existing scales and had a different underlying distribution for those identified at risk of falling and not (KS: 0.67, p<0.001). To reduce the time it takes to perform the test, we identified subsets of balance tasks that best predicted the StaBLE score across different populations. Together, our dataset, balance assessment protocol, and performance-based score demonstrate the validity of digital measures of balance.
Open AccessStaBLE: digital metrics capture balance performance across a wide spectrum of balance tasks and abilities
Balance is fundamental to mobility and independence, yet it remains difficult to measure in a way that is both clinically meaningful and feasible for widespread adoption. There is a need for more quantitative, objective, and accessible balance assessments. To this end, we created the Stanford Balance Level Evaluation (StaBLE), a battery of 18 balance-challenging tasks and accompanying digital performance metrics computed from video that aimed to capture widely ranging balance abilities across 180 participants. We validated the StaBLE score against existing clinical scales and found that it correlated with age (ρ = -0.76, p<0.001), the Activities-Specific Balance Confidence Scale (ρ = 0.60, p<0.001), a Mini-Balance Evaluation Systems Test task (τ=0.55, p<0.001), 4-Stage Balance Test (τ = 0.55, p<0.001), and Short Physical Performance Battery (τ =0.57, p<0.001). StaBLE overcame ceiling effects in these existing scales and had a different underlying distribution for those identified at risk of falling and not (KS: 0.67, p<0.001). To reduce the time it takes to perform the test, we identified subsets of balance tasks that best predicted the StaBLE score across different populations. Together, our dataset, balance assessment protocol, and performance-based score demonstrate the validity of digital measures of balance.
- 4 August 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Robotics
- Vol. 41 (15523098) , 4941-4959
Online Adaptation Framework Enables Personalization of Exoskeleton Assistance During Locomotion in Patients Affected by Stroke
Robotic exoskeletons can transform mobility for individuals with lower limb disabilities. However, their widespread adoption is limited by controller degradation caused by varying gait dynamics across different users and environments. Here, we propose an online adaptation framework that leverages real-time data streams to continuously update the user state estimator model. This approach allows the exoskeleton to learn the user-specific gait patterns, effectively customizing the model for each new user. In addition, we demonstrate a sensor signal transformation technique that enables model transfer across different exoskeleton hardware (from a research-grade exoskeleton to a commercial device). With less than one minute of adaptation, our framework improved gait phase estimation, which directly affects assistance timing, by 40.9% for able-bodied subjects and 65.9% for stroke survivors ($p$ $< $ 0.05), and reduced torque profile error by 32.7% compared to the baseline model ($p$ $< $ 0.05). Furthermore, in a pilot test, we applied our adaptation framework with human-in-the-loop optimization for control tuning. In a single stroke survivor, this approach led to a 21.8% increase in walking speed and a 6.5% reduction in metabolic cost compared to walking without exoskeleton. While preliminary, these results suggest the potential for personalized exoskeleton assistance in clinical populations.
- 4 August 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Robotics
- Vol. 41 (15523098) , 4941-4959
Online Adaptation Framework Enables Personalization of Exoskeleton Assistance During Locomotion in Patients Affected by Stroke
Robotic exoskeletons can transform mobility for individuals with lower limb disabilities. However, their widespread adoption is limited by controller degradation caused by varying gait dynamics across different users and environments. Here, we propose an online adaptation framework that leverages real-time data streams to continuously update the user state estimator model. This approach allows the exoskeleton to learn the user-specific gait patterns, effectively customizing the model for each new user. In addition, we demonstrate a sensor signal transformation technique that enables model transfer across different exoskeleton hardware (from a research-grade exoskeleton to a commercial device). With less than one minute of adaptation, our framework improved gait phase estimation, which directly affects assistance timing, by 40.9% for able-bodied subjects and 65.9% for stroke survivors ($p$ $< $ 0.05), and reduced torque profile error by 32.7% compared to the baseline model ($p$ $< $ 0.05). Furthermore, in a pilot test, we applied our adaptation framework with human-in-the-loop optimization for control tuning. In a single stroke survivor, this approach led to a 21.8% increase in walking speed and a 6.5% reduction in metabolic cost compared to walking without exoskeleton. While preliminary, these results suggest the potential for personalized exoskeleton assistance in clinical populations.
- 30 January 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 72 (7) , 2147-2156
Human-in-the-Loop Optimization of Hip Exoskeleton Assistance During Stair Climbing
Objective: This study applies human-in-the-loop optimization to identify optimal hip exoskeleton assistance patterns for stair climbing. Methods: Ten participants underwent optimization to individualize hip flexion and extension assistance, followed by a validation comparing optimized assistance (OPT) to biological hip moment-based assistance (BIO), no assistance (No-Assist), and no exoskeleton (No-Exo) conditions. Results: OPT reduced metabolic cost by 4.5% compared to No-Exo, 11.44% compared to No-Assist, and 5.02% compared to BIO, demonstrating the effectiveness of the optimization approach. Statistical analysis revealed distinct characteristics in optimal assistance timing and magnitude that deviated systematically from biological hip moment patterns. Compared to BIO, OPT exhibited later peak flexion timing (76.4 $\pm$ 3.7% vs 65.0%), shorter flexion duration (29.2 $\pm$ 3.6% vs 40.0%), later peak extension timing (26.7 $\pm$ 3.8% vs 20.0% of gait cycle), and higher peak flexion magnitude (11.1 $\pm$ 1.5 Nm vs 10.0 Nm). While individual optimal assistance profiles varied across participants, comparison between individually optimized parameters and the best subject-independent parameters identified through post-hoc analysis showed consistency. On average, metabolic rate convergence was achieved after 18 iterations, while most exoskeleton control parameters did not reach our convergence criteria within 20 iterations. Conclusion: These findings demonstrate that human-in-the-loop optimization can effectively identify task-specific assistance patterns for stair climbing, while the consistency between individual and subject-independent parameters suggests the potential for developing generalized assistance strategies. The systematic differences between optimized and biological moment-based assistance underscore the fundamental distinctions between biological torque-based control and optimal control for exoskeleton assistance.
- 30 January 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 72 (7) , 2147-2156
Human-in-the-Loop Optimization of Hip Exoskeleton Assistance During Stair Climbing
Objective: This study applies human-in-the-loop optimization to identify optimal hip exoskeleton assistance patterns for stair climbing. Methods: Ten participants underwent optimization to individualize hip flexion and extension assistance, followed by a validation comparing optimized assistance (OPT) to biological hip moment-based assistance (BIO), no assistance (No-Assist), and no exoskeleton (No-Exo) conditions. Results: OPT reduced metabolic cost by 4.5% compared to No-Exo, 11.44% compared to No-Assist, and 5.02% compared to BIO, demonstrating the effectiveness of the optimization approach. Statistical analysis revealed distinct characteristics in optimal assistance timing and magnitude that deviated systematically from biological hip moment patterns. Compared to BIO, OPT exhibited later peak flexion timing (76.4 $\pm$ 3.7% vs 65.0%), shorter flexion duration (29.2 $\pm$ 3.6% vs 40.0%), later peak extension timing (26.7 $\pm$ 3.8% vs 20.0% of gait cycle), and higher peak flexion magnitude (11.1 $\pm$ 1.5 Nm vs 10.0 Nm). While individual optimal assistance profiles varied across participants, comparison between individually optimized parameters and the best subject-independent parameters identified through post-hoc analysis showed consistency. On average, metabolic rate convergence was achieved after 18 iterations, while most exoskeleton control parameters did not reach our convergence criteria within 20 iterations. Conclusion: These findings demonstrate that human-in-the-loop optimization can effectively identify task-specific assistance patterns for stair climbing, while the consistency between individual and subject-independent parameters suggests the potential for developing generalized assistance strategies. The systematic differences between optimized and biological moment-based assistance underscore the fundamental distinctions between biological torque-based control and optimal control for exoskeleton assistance.
- 27 January 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics and Automation Letters
- Vol. 10 (4) , 3206-3213
Mode-Unified Intent Estimation of a Robotic Prosthesis Using Deep-Learning
Traditional robotic knee-ankle prostheses categorize ambulation modes such as level walking, ramps, and stairs. However, human movement scales continuously across various states rather than discretely, making traditional mode classifiers inadequate for accurate intent recognition. This letter proposes a mode-unified intent recognition strategy that continuously estimates terrain slopes across five modes: level ground, ramp ascent/descent, and stair ascent/descent. Locomotion data from 16 individuals with transfemoral amputation were utilized to train slope estimation and mode classification models based on deep temporal convolutional networks. The proposed method was compared to the traditional mode classifier via offline test, using leave-one-subject-out validations for the user-independent performance. The mode-unified slope estimator achieved an MAE of 1.68 ± 0.60 degrees, outperforming the mode classifier's MAE of 1.94 ± 0.97 degrees (p<0.05). The lower slope estimation errors resulted in higher accuracy in replicating knee kinematics of able-bodied subjects, with the proposed system achieving an average MAE of 5.13 ± 2.00 degrees for knee clearance and 6.74 ± 2.97 degrees for knee contact angle, compared to the traditional classifier's 12.10 ± 5.20 degrees and 13.80 ± 3.28 degrees (p<0.01), respectively, in stair ascent. These results suggest that our mode-unified approach can enable continuous adjustment to terrains without mode classification.
- 27 January 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics and Automation Letters
- Vol. 10 (4) , 3206-3213
Mode-Unified Intent Estimation of a Robotic Prosthesis Using Deep-Learning
Traditional robotic knee-ankle prostheses categorize ambulation modes such as level walking, ramps, and stairs. However, human movement scales continuously across various states rather than discretely, making traditional mode classifiers inadequate for accurate intent recognition. This letter proposes a mode-unified intent recognition strategy that continuously estimates terrain slopes across five modes: level ground, ramp ascent/descent, and stair ascent/descent. Locomotion data from 16 individuals with transfemoral amputation were utilized to train slope estimation and mode classification models based on deep temporal convolutional networks. The proposed method was compared to the traditional mode classifier via offline test, using leave-one-subject-out validations for the user-independent performance. The mode-unified slope estimator achieved an MAE of 1.68 ± 0.60 degrees, outperforming the mode classifier's MAE of 1.94 ± 0.97 degrees (p<0.05). The lower slope estimation errors resulted in higher accuracy in replicating knee kinematics of able-bodied subjects, with the proposed system achieving an average MAE of 5.13 ± 2.00 degrees for knee clearance and 6.74 ± 2.97 degrees for knee contact angle, compared to the traditional classifier's 12.10 ± 5.20 degrees and 13.80 ± 3.28 degrees (p<0.01), respectively, in stair ascent. These results suggest that our mode-unified approach can enable continuous adjustment to terrains without mode classification.
- Top Cited PapersOpen Access
- 20 December 2024
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 10 (51) , eadq0288
AI-driven universal lower-limb exoskeleton system for community ambulation
Exoskeletons offer promising solutions for improving human mobility, but a key challenge is ensuring the controller adapts to changing walking conditions. We present an artificial intelligence (AI)–driven universal exoskeleton system that dynamically switches assistance types between walking modes, modulates assistance levels corresponding to the ground slope, and delivers assistance timely based on the current gait phase in real-time. During treadmill validation, AI-based assistance reduced metabolic cost by 6.5% compared to 3.5% for conventional assistance. We expanded testing the controller in real-world walking, where AI-based assistance showed effective modulation and higher user preference compared to conventional assistance. Leveraging the AI-based approach and a comprehensive dataset, the controller achieved superior performance in environment- and user-state estimations. This approach does not require a separate mode classifier and operates on a user-independent basis, enabling immediate deployment across diverse conditions. This study highlights the potential of AI-driven exoskeletons in facilitating human locomotion in real-world ambulation.
- 20 December 2024
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 10 (51) , eadq0288
Top Cited PapersOpen AccessAI-driven universal lower-limb exoskeleton system for community ambulation
Exoskeletons offer promising solutions for improving human mobility, but a key challenge is ensuring the controller adapts to changing walking conditions. We present an artificial intelligence (AI)–driven universal exoskeleton system that dynamically switches assistance types between walking modes, modulates assistance levels corresponding to the ground slope, and delivers assistance timely based on the current gait phase in real-time. During treadmill validation, AI-based assistance reduced metabolic cost by 6.5% compared to 3.5% for conventional assistance. We expanded testing the controller in real-world walking, where AI-based assistance showed effective modulation and higher user preference compared to conventional assistance. Leveraging the AI-based approach and a comprehensive dataset, the controller achieved superior performance in environment- and user-state estimations. This approach does not require a separate mode classifier and operates on a user-independent basis, enabling immediate deployment across diverse conditions. This study highlights the potential of AI-driven exoskeletons in facilitating human locomotion in real-world ambulation.
- 21 September 2024
- Published by ASME International in Journal of Biomechanical Engineering
- Vol. 146 (12) , 1-33
Mitigating Crouch Gait With an Autonomous Pediatric Knee Exoskeleton in the Neurologically Impaired
Crouch gait is one of the most common compensatory walking patterns found in individuals with neurological disorders, often accompanied by their limited physical capacity. Notable kinematic characteristics of crouch gait are excessive knee flexion during stance and reduced range of motion during swing. Knee exoskeletons have the potential to improve crouch gait by providing precisely controlled torque assistance directly to the knee joint. In this study, we implemented a finite-state machine-based impedance controller for a powered knee exoskeleton to provide assistance during both stance and swing phases for five children and young adults who exhibit chronic crouch gait. The assistance provided a strong orthotic effect, increasing stance phase knee extension by an average of 12 deg. Additionally, the knee range of motion during swing was increased by an average of 15 deg. Changes to spatiotemporal outcomes, such as preferred walking speed and percent stance phase, were inconsistent across subjects and indicative of the underlying intricacies of user response to assistance. This study demonstrates the potential of knee exoskeletons operating in impedance control to mitigate the negative kinematic characteristics of crouch gait during both stance and swing phases of gait.
- 21 September 2024
- Published by ASME International in Journal of Biomechanical Engineering
- Vol. 146 (12) , 1-33
Mitigating Crouch Gait With an Autonomous Pediatric Knee Exoskeleton in the Neurologically Impaired
Crouch gait is one of the most common compensatory walking patterns found in individuals with neurological disorders, often accompanied by their limited physical capacity. Notable kinematic characteristics of crouch gait are excessive knee flexion during stance and reduced range of motion during swing. Knee exoskeletons have the potential to improve crouch gait by providing precisely controlled torque assistance directly to the knee joint. In this study, we implemented a finite-state machine-based impedance controller for a powered knee exoskeleton to provide assistance during both stance and swing phases for five children and young adults who exhibit chronic crouch gait. The assistance provided a strong orthotic effect, increasing stance phase knee extension by an average of 12 deg. Additionally, the knee range of motion during swing was increased by an average of 15 deg. Changes to spatiotemporal outcomes, such as preferred walking speed and percent stance phase, were inconsistent across subjects and indicative of the underlying intricacies of user response to assistance. This study demonstrates the potential of knee exoskeletons operating in impedance control to mitigate the negative kinematic characteristics of crouch gait during both stance and swing phases of gait.
- 3 November 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Robotics and Bionics
- Vol. 6 (1) , 224-234
Comparing Metabolic Cost and Muscle Activation for Knee and Back Exoskeletons in Lifting
Performing heavy manual lifting jobs can be extremely strenuous, often resulting in high rates of injury at overloaded joints. Lower-body exoskeletons have potential to mitigate this fatigue and injury through targeted joint assistance. A variety of current wearable devices aim to provide this kind of support, but their effects on both directly and indirectly targeted joints have not been fully investigated. In this study, a powered bilateral knee exoskeleton (research device), and passive back exosuit (HeroWear Apex) were compared across 10 individuals through a battery of manual lifting tasks. Metabolic, electromyographic, and subject-reported outcome measure data were used to determine which exoskeleton provided the best assistance for each task type. It was found that the knee exoskeleton significantly reduced metabolic cost by 9.6% compared to the no-exoskeleton baseline (p<.05). Both the knee and back exoskeletons reduced activation in up to 6 of the muscles measured (out of 16). Importantly, each device primarily reduced muscle activation around the joint it targeted, not around adjacent joints. These findings suggest that exoskeletons that target the knee or lower back joint during lifting can provide significant assistance in reducing exertion.
- 3 November 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Robotics and Bionics
- Vol. 6 (1) , 224-234
Comparing Metabolic Cost and Muscle Activation for Knee and Back Exoskeletons in Lifting
Performing heavy manual lifting jobs can be extremely strenuous, often resulting in high rates of injury at overloaded joints. Lower-body exoskeletons have potential to mitigate this fatigue and injury through targeted joint assistance. A variety of current wearable devices aim to provide this kind of support, but their effects on both directly and indirectly targeted joints have not been fully investigated. In this study, a powered bilateral knee exoskeleton (research device), and passive back exosuit (HeroWear Apex) were compared across 10 individuals through a battery of manual lifting tasks. Metabolic, electromyographic, and subject-reported outcome measure data were used to determine which exoskeleton provided the best assistance for each task type. It was found that the knee exoskeleton significantly reduced metabolic cost by 9.6% compared to the no-exoskeleton baseline (p<.05). Both the knee and back exoskeletons reduced activation in up to 6 of the muscles measured (out of 16). Importantly, each device primarily reduced muscle activation around the joint it targeted, not around adjacent joints. These findings suggest that exoskeletons that target the knee or lower back joint during lifting can provide significant assistance in reducing exertion.
- 1 June 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 70 (12) , 3312-3320
Reducing Knee Hyperextension With an Exoskeleton in Children and Adolescents With Genu Recurvatum: A Feasibility Study
Genu recurvatum, or knee hyperextension, is a complex gait pattern with a variety of etiologies, and is often connected with knee weakness, lack of motor control, and spasticity. Because of the atypical forces placed on the soft tissues, early treatment or prevention of knee hyperextension may help prevent further degradation of the knee joint. In this study, we assessed the feasibility of a knee exoskeleton to mitigate hyperextension and increase swing range of motion in five children/adolescents who presented with unilateral genu recurvatum. Over the course of three visits, each participant practiced walking with the exoskeleton, which provided torque assistance during both stance and swing based on an impedance control law. In final validation trials, the exoskeleton was effective in reducing knee hyperextension (0.2 ± 4.7° average peak knee extension without exo to 9.9 ± 10.3° with exo) and improving swing range of motion by 14.0 ± 4.5° increase on average. However, while the exoskeleton was effective in normalizing the kinematics, it did not lead to improved spatio-temporal asymmetry measures. This work showcases a promising potential application of a robotic knee exoskeleton for improving the kinematic characteristics of genu recurvatum gait.
- 1 June 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 70 (12) , 3312-3320
Reducing Knee Hyperextension With an Exoskeleton in Children and Adolescents With Genu Recurvatum: A Feasibility Study
Genu recurvatum, or knee hyperextension, is a complex gait pattern with a variety of etiologies, and is often connected with knee weakness, lack of motor control, and spasticity. Because of the atypical forces placed on the soft tissues, early treatment or prevention of knee hyperextension may help prevent further degradation of the knee joint. In this study, we assessed the feasibility of a knee exoskeleton to mitigate hyperextension and increase swing range of motion in five children/adolescents who presented with unilateral genu recurvatum. Over the course of three visits, each participant practiced walking with the exoskeleton, which provided torque assistance during both stance and swing based on an impedance control law. In final validation trials, the exoskeleton was effective in reducing knee hyperextension (0.2 ± 4.7° average peak knee extension without exo to 9.9 ± 10.3° with exo) and improving swing range of motion by 14.0 ± 4.5° increase on average. However, while the exoskeleton was effective in normalizing the kinematics, it did not lead to improved spatio-temporal asymmetry measures. This work showcases a promising potential application of a robotic knee exoskeleton for improving the kinematic characteristics of genu recurvatum gait.
- 27 March 2022
- Published by Springer Nature in Annals of Biomedical Engineering
- Vol. 50 (6) , 716-727
Effect of Assistance Using a Bilateral Robotic Knee Exoskeleton on Tibiofemoral Force Using a Neuromuscular Model
Tibiofemoral compression forces present during locomotion can result in high stress and risk damage to the knee. Powered assistance using a knee exoskeleton may reduce the knee load by reducing the work required by the muscles. However, the exact effect of assistance on the tibiofemoral force is unknown. The goal of this study was to investigate the effect of knee extension assistance during the early stance phase on the tibiofemoral force. Nine able-bodied adults walked on an inclined treadmill with a bilateral knee exoskeleton with assistance and with no assistance. Using an EMG-informed neuromusculoskeletal model, muscle forces were estimated, then utilized to estimate the tibiofemoral contact force. Results showed a 28% reduction in the knee moment, which resulted in approximately a 15% decrease in knee extensor muscle activation and a 20% reduction in subsequent muscle force, leading to a significant 10% reduction in peak and 9% reduction in average tibiofemoral contact force during the early stance phase (p < 0.05). The results indicate the tibiofemoral force is highly dependent on the knee kinetics and quadricep muscle activation due to their influence on knee extensor muscle forces, the primary contributor to the knee load.
- 27 March 2022
- Published by Springer Nature in Annals of Biomedical Engineering
- Vol. 50 (6) , 716-727
Effect of Assistance Using a Bilateral Robotic Knee Exoskeleton on Tibiofemoral Force Using a Neuromuscular Model
Tibiofemoral compression forces present during locomotion can result in high stress and risk damage to the knee. Powered assistance using a knee exoskeleton may reduce the knee load by reducing the work required by the muscles. However, the exact effect of assistance on the tibiofemoral force is unknown. The goal of this study was to investigate the effect of knee extension assistance during the early stance phase on the tibiofemoral force. Nine able-bodied adults walked on an inclined treadmill with a bilateral knee exoskeleton with assistance and with no assistance. Using an EMG-informed neuromusculoskeletal model, muscle forces were estimated, then utilized to estimate the tibiofemoral contact force. Results showed a 28% reduction in the knee moment, which resulted in approximately a 15% decrease in knee extensor muscle activation and a 20% reduction in subsequent muscle force, leading to a significant 10% reduction in peak and 9% reduction in average tibiofemoral contact force during the early stance phase (p < 0.05). The results indicate the tibiofemoral force is highly dependent on the knee kinetics and quadricep muscle activation due to their influence on knee extensor muscle forces, the primary contributor to the knee load.
- 25 May 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 68 (9) , 2870-2879
Biomechanical Comparison of Assistance Strategies Using a Bilateral Robotic Knee Exoskeleton
Despite there being studies that have investigated the effects of human augmentation using a knee exoskeleton, comparing different assistance schemes on a single knee exoskeleton has not been studied. Using a light-weight, low-profile bilateral knee exoskeleton system, this study examined and compared the biomechanical effects of three common assistance strategies (biological torque, impedance, and proportional myoelectric controllers) exhibiting different levels of flexibility for the user to control the assistance. Nine subjects walked on a 15% gradient incline surface at 1.1 m/s in the three powered conditions and with the exoskeleton unpowered. All the assistance strategies significantly reduced the metabolic cost of the users compared to the unpowered condition by 3.0% on average across strategies (p <; 0.05), led by the significant reduction in the biological knee kinetic effort and knee extensor muscle activation (p <; 0.05). Between assistance strategies, the metabolic cost and biomechanics displayed no statistically significant differences. The metabolic and biomechanical results indicate that powered extension assistance during early stance can improve performance compared to the unpowered condition. However, the user's ability to control the assistance may not be significant for human augmentation when walking on an inclined surface with a knee exoskeleton.
- 25 May 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 68 (9) , 2870-2879
Biomechanical Comparison of Assistance Strategies Using a Bilateral Robotic Knee Exoskeleton
Despite there being studies that have investigated the effects of human augmentation using a knee exoskeleton, comparing different assistance schemes on a single knee exoskeleton has not been studied. Using a light-weight, low-profile bilateral knee exoskeleton system, this study examined and compared the biomechanical effects of three common assistance strategies (biological torque, impedance, and proportional myoelectric controllers) exhibiting different levels of flexibility for the user to control the assistance. Nine subjects walked on a 15% gradient incline surface at 1.1 m/s in the three powered conditions and with the exoskeleton unpowered. All the assistance strategies significantly reduced the metabolic cost of the users compared to the unpowered condition by 3.0% on average across strategies (p <; 0.05), led by the significant reduction in the biological knee kinetic effort and knee extensor muscle activation (p <; 0.05). Between assistance strategies, the metabolic cost and biomechanics displayed no statistically significant differences. The metabolic and biomechanical results indicate that powered extension assistance during early stance can improve performance compared to the unpowered condition. However, the user's ability to control the assistance may not be significant for human augmentation when walking on an inclined surface with a knee exoskeleton.