Kinsey R. Herrin
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Kinsey R. Herrin has a total of 80 co-authors. Here are the top co-authors by number of shared publications:
- Aaron J. Young
Georgia Institute of Technology
16 shared publications - Dawit Lee
Department of Bioengineering, Stanford University, Stanford, CA, USA
4 shared publications - Jaydev P. Desai
Wallace H. Coulter Department of Biomedical Engineering, Medical Robotics and Automation (RoboMed) Laboratory, Georgia Institute of Technology, Atlanta, GA, USA
4 shared publications - Krishan Bhakta
Woodruff School of Mechanical Engineering, Georgia Institute of Technology, Atlanta, GA, USA
4 shared publications - Phillip Tran
Medical Robotics and Automation (RoboMed) Laboratory, Georgia Center for Medical Robotics, Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology, Atlanta, GA, USA
4 shared publications - Sixu Zhou
Woodruff School of Mechanical Engineering and the Institute for Robotics and Intelligent Machines, Georgia Institute of Technology, Atlanta, GA, USA
4 shared publications
Latest Publications
- 1 November 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics and Automation Letters
- Vol. 11 (11) , 13024-13030
Mobile Machine Learning Predictions of Bilateral Ground Reaction Forces During Variable Speed Walking and Prosthesis Use
- 1 November 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics and Automation Letters
- Vol. 11 (11) , 13024-13030
Mobile Machine Learning Predictions of Bilateral Ground Reaction Forces During Variable Speed Walking and Prosthesis Use
- Open Access
Toward personalizing prosthesis prescription: A take‐home study of three microprocessor‐controlled prosthetic knees: A randomized crossover study
Background: Previous studies on microprocessor‐controlled prosthetic knees (MPKs) often investigate benefits of MPKs as a class of knees rather than clinically relevant differences between specific knees, despite their distinct features. Objectives: To systematically evaluate and report outcomes associated with three commercially available MPKs following a standardized real‐world use period. Design: Randomized crossover study. Setting: Research laboratory and community environment. Participants: Ten patients with transfemoral amputation. Interventions: Three MPKs were fitted, trained, and worn for a 1‐week period including C‐Leg 4.0 (Ottobock, Duderstadt, Germany), Rheo Knee‐Model RM7 (Össur, Reykjavik, Iceland), and Power Knee‐PKA01 (Össur, Reykjavik, Iceland). Main Outcome Measures: Primary outcomes were the 10‐meter walk test (10‐mwt), the 2‐minute walk test (2‐mwt), and the Prosthesis Evaluation Questionnaire (PEQ). Secondary outcomes were stance time asymmetry, physiological cost index, stair and ramp speeds, the narrowing beam walking test, and community ambulation monitoring. Results: Participants walked 11% faster in Rheo than Power Knee during the 10‐mwt (95% confidence interval [CI]: 0.046–0.184, p = .015). In the 2‐mwt, participants walked 12% faster in C‐Leg (95% CI: 0.034–0.241, p = .003) and 9% faster in Rheo (95% CI: 0.031, 0.163, p = .027) than in Power Knee. On the PEQ, participants reported greater satisfaction with C‐Leg compared to Power Knee ( p = .006). Ramp ascent speed was 8% faster in Rheo than Power Knee (95% CI: 0.026–0.130, p = .024). No significant differences were found for other secondary outcomes. Notably, 10 of 12 outcomes showed individuals performing their best by a defined difference on an MPK different from the cohort's best‐performing MPK. Conclusions: Participants walked faster in C‐Leg and Rheo than Power Knee and reported greater satisfaction with C‐Leg. Consideration of patient needs and characteristics may allow more individualized MPK prescription and thereby improve rehabilitation outcomes. Database Registration: NCT06399471.
Open AccessToward personalizing prosthesis prescription: A take‐home study of three microprocessor‐controlled prosthetic knees: A randomized crossover study
Background: Previous studies on microprocessor‐controlled prosthetic knees (MPKs) often investigate benefits of MPKs as a class of knees rather than clinically relevant differences between specific knees, despite their distinct features. Objectives: To systematically evaluate and report outcomes associated with three commercially available MPKs following a standardized real‐world use period. Design: Randomized crossover study. Setting: Research laboratory and community environment. Participants: Ten patients with transfemoral amputation. Interventions: Three MPKs were fitted, trained, and worn for a 1‐week period including C‐Leg 4.0 (Ottobock, Duderstadt, Germany), Rheo Knee‐Model RM7 (Össur, Reykjavik, Iceland), and Power Knee‐PKA01 (Össur, Reykjavik, Iceland). Main Outcome Measures: Primary outcomes were the 10‐meter walk test (10‐mwt), the 2‐minute walk test (2‐mwt), and the Prosthesis Evaluation Questionnaire (PEQ). Secondary outcomes were stance time asymmetry, physiological cost index, stair and ramp speeds, the narrowing beam walking test, and community ambulation monitoring. Results: Participants walked 11% faster in Rheo than Power Knee during the 10‐mwt (95% confidence interval [CI]: 0.046–0.184, p = .015). In the 2‐mwt, participants walked 12% faster in C‐Leg (95% CI: 0.034–0.241, p = .003) and 9% faster in Rheo (95% CI: 0.031, 0.163, p = .027) than in Power Knee. On the PEQ, participants reported greater satisfaction with C‐Leg compared to Power Knee ( p = .006). Ramp ascent speed was 8% faster in Rheo than Power Knee (95% CI: 0.026–0.130, p = .024). No significant differences were found for other secondary outcomes. Notably, 10 of 12 outcomes showed individuals performing their best by a defined difference on an MPK different from the cohort's best‐performing MPK. Conclusions: Participants walked faster in C‐Leg and Rheo than Power Knee and reported greater satisfaction with C‐Leg. Consideration of patient needs and characteristics may allow more individualized MPK prescription and thereby improve rehabilitation outcomes. Database Registration: NCT06399471.
- 8 August 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Robotics and Bionics
- Vol. 7 (4) , 1634-1645
Real-Time Balancing of Stability and Plasticity in Continual Learning Enables Adaptive Speed Estimation for Lower-Limb Prostheses
A primary challenge in continual learning (CL) for wearable robotics, especially prosthetics, is balancing the need to retain learned knowledge (stability) with the necessity to adapt to new information (plasticity). This balance is crucial for online adaptation, enabling systems to transition between tasks without losing prior knowledge. In this paper, we introduce a novel online optimizer-based framework designed to manage the stability-plasticity balance through strategic datapoint replay and learning-rate adjustments of a deep neural network. We applied this framework to speed estimation systems for transfemoral prostheses (TFA users), conducting offline validation tests using data from 10 individuals with TFA, and online tests with three TFA and six able-bodied (AB) participants. Our results demonstrate statistically significant improvements: in offline settings, our method showed a 39.2% increase in stability and a 35.2% boost in plasticity over traditional CL approaches during leave-one-subject-out validation. Similarly, in real-time trials with AB participants, we observed statistically significant gains in handling both previously encountered and new walking speeds. Finally, trials with individuals with TFA showed that the system improved the plasticity of the baseline model by 67.45% and the stability of the traditional CL approach by 31.36%; reducing overall average walking speed estimation error by 19.47%.
- 8 August 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Robotics and Bionics
- Vol. 7 (4) , 1634-1645
Real-Time Balancing of Stability and Plasticity in Continual Learning Enables Adaptive Speed Estimation for Lower-Limb Prostheses
A primary challenge in continual learning (CL) for wearable robotics, especially prosthetics, is balancing the need to retain learned knowledge (stability) with the necessity to adapt to new information (plasticity). This balance is crucial for online adaptation, enabling systems to transition between tasks without losing prior knowledge. In this paper, we introduce a novel online optimizer-based framework designed to manage the stability-plasticity balance through strategic datapoint replay and learning-rate adjustments of a deep neural network. We applied this framework to speed estimation systems for transfemoral prostheses (TFA users), conducting offline validation tests using data from 10 individuals with TFA, and online tests with three TFA and six able-bodied (AB) participants. Our results demonstrate statistically significant improvements: in offline settings, our method showed a 39.2% increase in stability and a 35.2% boost in plasticity over traditional CL approaches during leave-one-subject-out validation. Similarly, in real-time trials with AB participants, we observed statistically significant gains in handling both previously encountered and new walking speeds. Finally, trials with individuals with TFA showed that the system improved the plasticity of the baseline model by 67.45% and the stability of the traditional CL approach by 31.36%; reducing overall average walking speed estimation error by 19.47%.
- 4 August 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Robotics
- Vol. 41 (15523098) , 4941-4959
Online Adaptation Framework Enables Personalization of Exoskeleton Assistance During Locomotion in Patients Affected by Stroke
Robotic exoskeletons can transform mobility for individuals with lower limb disabilities. However, their widespread adoption is limited by controller degradation caused by varying gait dynamics across different users and environments. Here, we propose an online adaptation framework that leverages real-time data streams to continuously update the user state estimator model. This approach allows the exoskeleton to learn the user-specific gait patterns, effectively customizing the model for each new user. In addition, we demonstrate a sensor signal transformation technique that enables model transfer across different exoskeleton hardware (from a research-grade exoskeleton to a commercial device). With less than one minute of adaptation, our framework improved gait phase estimation, which directly affects assistance timing, by 40.9% for able-bodied subjects and 65.9% for stroke survivors ($p$ $< $ 0.05), and reduced torque profile error by 32.7% compared to the baseline model ($p$ $< $ 0.05). Furthermore, in a pilot test, we applied our adaptation framework with human-in-the-loop optimization for control tuning. In a single stroke survivor, this approach led to a 21.8% increase in walking speed and a 6.5% reduction in metabolic cost compared to walking without exoskeleton. While preliminary, these results suggest the potential for personalized exoskeleton assistance in clinical populations.
- 4 August 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Robotics
- Vol. 41 (15523098) , 4941-4959
Online Adaptation Framework Enables Personalization of Exoskeleton Assistance During Locomotion in Patients Affected by Stroke
Robotic exoskeletons can transform mobility for individuals with lower limb disabilities. However, their widespread adoption is limited by controller degradation caused by varying gait dynamics across different users and environments. Here, we propose an online adaptation framework that leverages real-time data streams to continuously update the user state estimator model. This approach allows the exoskeleton to learn the user-specific gait patterns, effectively customizing the model for each new user. In addition, we demonstrate a sensor signal transformation technique that enables model transfer across different exoskeleton hardware (from a research-grade exoskeleton to a commercial device). With less than one minute of adaptation, our framework improved gait phase estimation, which directly affects assistance timing, by 40.9% for able-bodied subjects and 65.9% for stroke survivors ($p$ $< $ 0.05), and reduced torque profile error by 32.7% compared to the baseline model ($p$ $< $ 0.05). Furthermore, in a pilot test, we applied our adaptation framework with human-in-the-loop optimization for control tuning. In a single stroke survivor, this approach led to a 21.8% increase in walking speed and a 6.5% reduction in metabolic cost compared to walking without exoskeleton. While preliminary, these results suggest the potential for personalized exoskeleton assistance in clinical populations.
- 1 August 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Robotics and Bionics
- Vol. 7 (3) , 1263-1274
An Anthropometry-Based Personalization of Powered Knee Prosthesis for Metabolic Efficiency
- 1 August 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Robotics and Bionics
- Vol. 7 (3) , 1263-1274
An Anthropometry-Based Personalization of Powered Knee Prosthesis for Metabolic Efficiency
- 5 June 2025
- Published by Wolters Kluwer Health in Prosthetics and Orthotics International
- Vol. 50 (4) , 401-409
A clinical decision-making algorithm for the personalized prescription of microprocessor-controlled prosthetic knees: An evidence-based approach based on a randomized trial
Background: Current processes for identifying the best microprocessor-controlled prosthetic knee (MPK) for individuals with transfemoral amputations are subjective, nonscientific, and sometimes fail to consider unique patient needs. Inaccurate prescriptions may hinder a patient's ability to make a speedy rehab. Objectives: We developed a clinical decision equation that outputs MPK recommendation scores for 3 commercially available MPKs (Power Knee, C-Leg 4.0, Rheo Knee) based on easily acquirable user evaluation data. Study design: Participants wore each of the study MPKs at home for a 1-week acclimation period. On the experiment day, participants completed a set of functional tasks including a 10-m walk test, stair and ramp ambulation tasks, a 2-minute walk test, and a narrow beam walking test. Performance outcome measures were collected. Methods: Microprocessor-controlled prosthetic knees were scored relatively to the best performing knee based on their performance in 5 areas of interest: agility, community ambulation, energy, stability, and gait quality. The relative importance of each of these areas was computed based on a quantitative prediction of a user's functional needs from features including age, body mass index (BMI), AMPnoPRO score, and likelihood of stairs/ramps. We describe the algorithm-suggested optimal patient profiles for each device. Results: We developed an application that allows clinicians to obtain instant recommendations. Clinicians can further adjust the relative importance of each area of interest based on patient needs. Conclusions: This algorithm represents a transparent, experimentally backed clinical decision-making aid with the potential to streamline the prosthesis fitting process. Future studies are required to evaluate the effectiveness of the algorithm.
- 5 June 2025
- Published by Wolters Kluwer Health in Prosthetics and Orthotics International
- Vol. 50 (4) , 401-409
A clinical decision-making algorithm for the personalized prescription of microprocessor-controlled prosthetic knees: An evidence-based approach based on a randomized trial
Background: Current processes for identifying the best microprocessor-controlled prosthetic knee (MPK) for individuals with transfemoral amputations are subjective, nonscientific, and sometimes fail to consider unique patient needs. Inaccurate prescriptions may hinder a patient's ability to make a speedy rehab. Objectives: We developed a clinical decision equation that outputs MPK recommendation scores for 3 commercially available MPKs (Power Knee, C-Leg 4.0, Rheo Knee) based on easily acquirable user evaluation data. Study design: Participants wore each of the study MPKs at home for a 1-week acclimation period. On the experiment day, participants completed a set of functional tasks including a 10-m walk test, stair and ramp ambulation tasks, a 2-minute walk test, and a narrow beam walking test. Performance outcome measures were collected. Methods: Microprocessor-controlled prosthetic knees were scored relatively to the best performing knee based on their performance in 5 areas of interest: agility, community ambulation, energy, stability, and gait quality. The relative importance of each of these areas was computed based on a quantitative prediction of a user's functional needs from features including age, body mass index (BMI), AMPnoPRO score, and likelihood of stairs/ramps. We describe the algorithm-suggested optimal patient profiles for each device. Results: We developed an application that allows clinicians to obtain instant recommendations. Clinicians can further adjust the relative importance of each area of interest based on patient needs. Conclusions: This algorithm represents a transparent, experimentally backed clinical decision-making aid with the potential to streamline the prosthesis fitting process. Future studies are required to evaluate the effectiveness of the algorithm.
- 12 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Robotics and Bionics
- Vol. 7 (2) , 711-722
Real-Time Adaptation of Deep Learning Walking Speed Estimators Enables Biomimetic Assistance Modulation in an Open-Source Bionic Leg
This study introduces a novel continual learning algorithm that incrementally improves the performance of deep-learning-based walking speed estimators during level-ground walking with a powered knee-ankle prosthesis. While user-dependent (DEP) estimators generally outperform user-independent (IND) estimators, they require the pre-collection of DEP training data. In contrast, our real-time algorithm adapts IND estimators to self-labeled DEP data generated during walking, eliminating the need for pre-collected datasets. The algorithm also features a biomimetic scaling mechanism that adjusts prosthetic assistance based on speed estimates. We evaluated our algorithm on novel subjects (N=10) with unilateral above-knee amputations during treadmill and overground walking. For treadmill trials, when adapted with estimated and ground truth labels, estimators achieved mean absolute errors (MAEs) of 0.074 0.023 (mean, standard deviation) and 0.074 0.018 m/s, respectively, reflecting a significant 28% (p < 0.05) reduction in MAE compared to non-adapted estimators. For overground trials, treadmill-adapted estimators demonstrated a significant 18% (p < 0.05) reduction in MAE compared to non-adapted estimators. Our algorithm significantly reduced speed estimation errors within one minute of walking and delivered biomimetic assistance (r = 0.91) across speeds. This approach allows off-the-shelf powered prostheses to seamlessly adapt to new users, delivering biomimetic assistance through precise, real-time walking speed estimation.
- 12 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Robotics and Bionics
- Vol. 7 (2) , 711-722
Real-Time Adaptation of Deep Learning Walking Speed Estimators Enables Biomimetic Assistance Modulation in an Open-Source Bionic Leg
This study introduces a novel continual learning algorithm that incrementally improves the performance of deep-learning-based walking speed estimators during level-ground walking with a powered knee-ankle prosthesis. While user-dependent (DEP) estimators generally outperform user-independent (IND) estimators, they require the pre-collection of DEP training data. In contrast, our real-time algorithm adapts IND estimators to self-labeled DEP data generated during walking, eliminating the need for pre-collected datasets. The algorithm also features a biomimetic scaling mechanism that adjusts prosthetic assistance based on speed estimates. We evaluated our algorithm on novel subjects (N=10) with unilateral above-knee amputations during treadmill and overground walking. For treadmill trials, when adapted with estimated and ground truth labels, estimators achieved mean absolute errors (MAEs) of 0.074 0.023 (mean, standard deviation) and 0.074 0.018 m/s, respectively, reflecting a significant 28% (p < 0.05) reduction in MAE compared to non-adapted estimators. For overground trials, treadmill-adapted estimators demonstrated a significant 18% (p < 0.05) reduction in MAE compared to non-adapted estimators. Our algorithm significantly reduced speed estimation errors within one minute of walking and delivered biomimetic assistance (r = 0.91) across speeds. This approach allows off-the-shelf powered prostheses to seamlessly adapt to new users, delivering biomimetic assistance through precise, real-time walking speed estimation.
- 27 January 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics and Automation Letters
- Vol. 10 (4) , 3206-3213
Mode-Unified Intent Estimation of a Robotic Prosthesis Using Deep-Learning
Traditional robotic knee-ankle prostheses categorize ambulation modes such as level walking, ramps, and stairs. However, human movement scales continuously across various states rather than discretely, making traditional mode classifiers inadequate for accurate intent recognition. This letter proposes a mode-unified intent recognition strategy that continuously estimates terrain slopes across five modes: level ground, ramp ascent/descent, and stair ascent/descent. Locomotion data from 16 individuals with transfemoral amputation were utilized to train slope estimation and mode classification models based on deep temporal convolutional networks. The proposed method was compared to the traditional mode classifier via offline test, using leave-one-subject-out validations for the user-independent performance. The mode-unified slope estimator achieved an MAE of 1.68 ± 0.60 degrees, outperforming the mode classifier's MAE of 1.94 ± 0.97 degrees (p<0.05). The lower slope estimation errors resulted in higher accuracy in replicating knee kinematics of able-bodied subjects, with the proposed system achieving an average MAE of 5.13 ± 2.00 degrees for knee clearance and 6.74 ± 2.97 degrees for knee contact angle, compared to the traditional classifier's 12.10 ± 5.20 degrees and 13.80 ± 3.28 degrees (p<0.01), respectively, in stair ascent. These results suggest that our mode-unified approach can enable continuous adjustment to terrains without mode classification.
- 27 January 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics and Automation Letters
- Vol. 10 (4) , 3206-3213
Mode-Unified Intent Estimation of a Robotic Prosthesis Using Deep-Learning
Traditional robotic knee-ankle prostheses categorize ambulation modes such as level walking, ramps, and stairs. However, human movement scales continuously across various states rather than discretely, making traditional mode classifiers inadequate for accurate intent recognition. This letter proposes a mode-unified intent recognition strategy that continuously estimates terrain slopes across five modes: level ground, ramp ascent/descent, and stair ascent/descent. Locomotion data from 16 individuals with transfemoral amputation were utilized to train slope estimation and mode classification models based on deep temporal convolutional networks. The proposed method was compared to the traditional mode classifier via offline test, using leave-one-subject-out validations for the user-independent performance. The mode-unified slope estimator achieved an MAE of 1.68 ± 0.60 degrees, outperforming the mode classifier's MAE of 1.94 ± 0.97 degrees (p<0.05). The lower slope estimation errors resulted in higher accuracy in replicating knee kinematics of able-bodied subjects, with the proposed system achieving an average MAE of 5.13 ± 2.00 degrees for knee clearance and 6.74 ± 2.97 degrees for knee contact angle, compared to the traditional classifier's 12.10 ± 5.20 degrees and 13.80 ± 3.28 degrees (p<0.01), respectively, in stair ascent. These results suggest that our mode-unified approach can enable continuous adjustment to terrains without mode classification.
- Open Access
- 3 January 2025
- Published by ASME International in Journal of Biomechanical Engineering
- Vol. 147 (2) , 1-36
Continuous-Context, User-Independent, Real-Time Intent Recognition for Powered Lower-Limb Prostheses
Community ambulation is essential for maintaining a healthy lifestyle, but it poses significant challenges for individuals with limb loss due to complex task demands. In wearable robotics, particularly powered prostheses, there is a critical need to accurately estimate environmental context, such as walking speed and slope, to offer intuitive and seamless assistance during varied ambulation tasks. We developed a user-independent and multicontext, intent recognition system that was deployed in real-time on an Open Source Leg (OSL). We recruited 11 individuals with transfemoral amputation, with seven participants used for real-time validation. Our findings revealed two main conclusions: (1) the user-independent (IND) performance across speed and slope was not statistically different from user-dependent (DEP) models in real-time and did not degrade compared to its offline counterparts, and (2) IND walking speed estimates showed ∼0.09 m/s mean absolute error (MAE) and slope estimates showed ∼0.95 deg MAE across multicontext scenarios. Additionally, we provide an open-source dataset to facilitate further research in accurately estimating speed and slope using an IND approach in real-world walking tasks on a powered prosthesis.
- 3 January 2025
- Published by ASME International in Journal of Biomechanical Engineering
- Vol. 147 (2) , 1-36
Open AccessContinuous-Context, User-Independent, Real-Time Intent Recognition for Powered Lower-Limb Prostheses
Community ambulation is essential for maintaining a healthy lifestyle, but it poses significant challenges for individuals with limb loss due to complex task demands. In wearable robotics, particularly powered prostheses, there is a critical need to accurately estimate environmental context, such as walking speed and slope, to offer intuitive and seamless assistance during varied ambulation tasks. We developed a user-independent and multicontext, intent recognition system that was deployed in real-time on an Open Source Leg (OSL). We recruited 11 individuals with transfemoral amputation, with seven participants used for real-time validation. Our findings revealed two main conclusions: (1) the user-independent (IND) performance across speed and slope was not statistically different from user-dependent (DEP) models in real-time and did not degrade compared to its offline counterparts, and (2) IND walking speed estimates showed ∼0.09 m/s mean absolute error (MAE) and slope estimates showed ∼0.95 deg MAE across multicontext scenarios. Additionally, we provide an open-source dataset to facilitate further research in accurately estimating speed and slope using an IND approach in real-world walking tasks on a powered prosthesis.
- 16 December 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics and Automation Letters
- Vol. 10 (2) , 1011-1017
Robotic Ankle Exoskeleton and Limb Angle Biofeedback for Assisting Stroke Gait: A Feasibility Study
Post-stroke gait is slow, energetically costly, and unstable. Rehabilitation is necessary to encourage, retrain, and assist proper gait mechanics in stroke survivors. Evidence indicates robotic ankle exoskeletons can improve gait outcomes in stroke survivors, however challenges remain with proper lower limb positioning for optimal receipt of the assistance. Biofeedback can be used to improve positioning of the limb for receipt of robotic ankle exoskeleton assistance. In this study, four stroke survivors used bilateral powered robotic ankle exoskeletons (Dephy Exoboots) and an innovative, custom-designed vibrotactile-audio biofeedback interface targeting trailing limb angle to test the hypotheses that each intervention alone improves gait outcomes over baseline, and when combined they improve outcomes over either intervention alone. Compared to baseline, we found increases in average paretic propulsive impulse during the biofeedback-only and exoskeleton-plus-biofeedback conditions. Biofeedback alone induced the greatest increase on average self-selected walking speed, and the combination of exoskeleton assistance and biofeedback increased speed more compared to the robotic exoskeleton-only condition. Our preliminary results indicate that biofeedback in combination with a robotic exoskeleton produces greater synergistic benefits on gait performance than the use of an exoskeleton alone.
- 16 December 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics and Automation Letters
- Vol. 10 (2) , 1011-1017
Robotic Ankle Exoskeleton and Limb Angle Biofeedback for Assisting Stroke Gait: A Feasibility Study
Post-stroke gait is slow, energetically costly, and unstable. Rehabilitation is necessary to encourage, retrain, and assist proper gait mechanics in stroke survivors. Evidence indicates robotic ankle exoskeletons can improve gait outcomes in stroke survivors, however challenges remain with proper lower limb positioning for optimal receipt of the assistance. Biofeedback can be used to improve positioning of the limb for receipt of robotic ankle exoskeleton assistance. In this study, four stroke survivors used bilateral powered robotic ankle exoskeletons (Dephy Exoboots) and an innovative, custom-designed vibrotactile-audio biofeedback interface targeting trailing limb angle to test the hypotheses that each intervention alone improves gait outcomes over baseline, and when combined they improve outcomes over either intervention alone. Compared to baseline, we found increases in average paretic propulsive impulse during the biofeedback-only and exoskeleton-plus-biofeedback conditions. Biofeedback alone induced the greatest increase on average self-selected walking speed, and the combination of exoskeleton assistance and biofeedback increased speed more compared to the robotic exoskeleton-only condition. Our preliminary results indicate that biofeedback in combination with a robotic exoskeleton produces greater synergistic benefits on gait performance than the use of an exoskeleton alone.