    Vibration-Based Condition Classification of ASTM C93900 Bronze Plain-Bearing Bushings Using Deep Learning

    by J. V. Pelegrino, R. D. Dantas, M. R. Silva, D. A. Seixas, L. A. Willenshofer, C. M. P. Souza, W. C. Silva

  • Open Access

    Characterization of Ti-6Al-4V titanium alloy applied in hydroxyapatite coated hip prostheses

    by Caique Movio Pereira de Souza, Vanderlei Araujo Militão, Isaias Gouveia Silva, Rene Ramos de Oliveira, Vanessa Seriacopi, Wilson Carlos da Silva Junior

    Titanium and its alloys are widely used as biomaterials in hard tissue replacements due to their unique physiological environment responses and chemical and mechanical properties, such as corrosion resistance, fatigue resistance, and ductility. Other metals used as biomaterials have elastic modulus with values ​​ten times higher than human bone, which can cause failure when there are impacts. Several studies report hip prosthesis failures due to fatigue. This article aims to carry out studies on the mechanical properties and fatigue resistance in an environment that simulates those of the joints of the human body, using hip prostheses manufactured with Ti 6Al 4V alloy with hydroxyapatite coating. Samples were taken from the neck region for microstructural characterization to identify grain size, inclusions, microhardness, tensile test, scanning electron microscopy, energy dispersion spectroscopy, X-ray fluorescence,e, and X-ray diffraction also performed. After applying more than 10,000,000 cycles with compressive forces ranging from -0.3 kN to -3.0 kN, no cracks were found and it was observed that the part suffered only elastic deformations.


  • Open Access

    Data analyses of fatigue tests by extensometry in hip prosthesis of the Co-28Cr-6Mo alloy

    by Caique Movio Pereira de Souza, Raul Gaspari Santos, Renato Chaves Souza, Vanderlei Araujo Militão, Isaias Gouveia Silva, Vanessa Seriacopi, Wilson Carlos da Silva Junior

    ANVISA made changes to its regulations, setting new values for the fatigue tests, increasing the number of cycles that prostheses must endure without presenting failures. The standard used is ABNT NBR 7206-6:2013, in which all prostheses being commercialized must be tested in the new parameters. In this article, studies were conducted based on the requirement to revalidate the Co-26Cr-6Mo metallic alloy (ASTM F75). Microstructural characterizations (Optical and Scanning Electron Microscopies), and fatigue tests were carried out, with the aim of obtaining the mechanical behavior and features of the materials used in hip prostheses and comparing them with the standard. The grain size and inclusion contents were found to be controlled. Likewise, the prosthesis has withstand 10,000,000 cycles, and has not shown cracks, nor plastic deformations, enabling the biomedical use of this alloy according to the new regulations. Tensile test and liquid penetrant inspection were also carried out to take the parameters of the related physical properties. In the analysis with strain gauges, it was possible to detect the purely elastic deformation that occurred with the application of the load during fatigue tests, resulting in a slight variation of stress in the data acquisition system.

  • The use of titanium alloy (F136) in surgical implants

    by Wilson Carlos Silva Jr, Mauricio Pereira Silva, Rogério Homem Costa, Caique Movio Souza

    Titanium has been widely used in the area of biomaterials, the segment of manufacture of products for rehabilitation goes through a constant evolution, because each year new techniques appear, new technologies that help in the development of biomaterials, these evolutions are mostly aimed at cost reduction, osseointegration, biocompatibility among other factors. The objective of this article is to carry out the analysis of the fixation screws of the femur prosthesis and hip prostheses, manufactured in titanium alloy ASTM 136. The use of titanium alloys in orthopedic, dental and aeronautical applications has increased in recent decades. The use of titanium in biomaterials is due to its singularities in the physiological environment and its favorable chemical and mechanical properties such as good resistance to corrosion, high degree of biocompatibility and low modulus of elasticity. For the fixation screws, analyzes of their resistance to torsion and the fracture surfaces of the tested samples were performed, for the analyzes were used Scanning Electron Microscopy (SEM) and semiquantitative analysis of the chemical elements by X-ray spectroscopy by dispersion in (EDS) and for the hip prosthesis, the fatigue test will be carried out according to ABNT NBR 7206-6. These tests aim to verify if both are able to be sold on the national market. With the tests completed, the results were compared with the standards in force. The results of the torsion tests are presented, where all samples met the quality requirements and the hip prostheses showed a stable behavior during the 10.000.000 million cycles, without failures during or after the tests.


  • Comparison of function of passive modular exoskeletons for analysis of abduction movement and horizontal abduction of the upper limb

    by Ma Fumagalli, Ajc Pitta, Pcs Emanuel, V Costa, Cmp Souza

    Stroke is one of the biggest problems of the health system in Brazil and in the world: not only due to high health costs, but also due to the treatment that does not guarantee a complete functional recovery. About 25% of the patients do not survive, and almost half of the survivors have a functional limitation of the upper and / or lower limbs. In the human body, the skeletal structure provides mechanical support for movements. On the shoulder, we find the greatest amount of degrees of articular freedom of the body - it allows arm movements in almost all directions, as well as in different angles. Compromising any of your movements directly affects autonomy in activities of daily living. The tracking of movements of the shoulder girdle and upper limbs accompanied by biomechanical assessments in the performance of activities of daily living provides support for rehabilitation. This measurement, however, is a complex activity due to the number of interdependent joints and movements. The objective of this research is to compare the readings performed on two passive exoskeletons, which measure three-dimensionally the movement of the abduction / adduction and lateral abduction joints. To acquire the signals in the mechanical structure of the equipment, a reading system by a position sensor (encoder) is placed. The acquired signals are treated with a computational tool. The data are presented in real time, with visual feedback on joint movements. In the tests performed, the exoskeleton had no mechanical limitations that prevented the measurement of movements. Keywords. Upper limb, Exoskeleton, Measurement system.