Wilson Carlos da Silva Junior
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Wilson Carlos da Silva Junior has a total of 30 co-authors. Here are the top co-authors by number of shared publications:
- Caique Movio Pereira de Souza
UNISA: Universidade de Santo Amaro
4 shared publications - Antônio Augusto Couto
School of Engineering, Mackenzie Presbyterian University, São Paulo 01302-907, SP, Brazil
2 shared publications - Isaias Gouveia Silva
National Service for Industrial Apprenticeship
2 shared publications - João V. Pelegrino
IFSP
2 shared publications - Márcio Rodrigues da Silva
Department of Research and Development, Termomecanica São Paulo S.A., São Bernardo do Campo 09612-000, SP, Brazil
2 shared publications - Renato Chaves Souza
Federal Institute of Education, Science and Technology of São Paulo, São João da Boa Vista 13871-298, SP, Brazil
2 shared publications
Latest Publications
- Open Access
- 19 July 2026
- Published by Sociedade Brasileira de Computação
- p. 84-95
Análise comparativa de acelerômetros MEMS de baixo custo para detecção de falhas em rolamentos usando redes neurais convolucionais
A manutenção preditiva é essencial para a confiabilidade de máquinas rotativas, nas quais falhas em rolamentos são frequentes. Este trabalho avalia o uso de acelerômetros MEMS de baixo custo na detecção de falhas por meio de Redes Neurais Convolucionais (CNNs). Os sinais de vibração foram coletados a 200 RPM em três condições: normal, falha no elemento rolante e falha na pista interna. Após pré-processamento, os dados foram convertidos em matrizes 8×8 para entrada na CNN. O modelo alcançou aproximadamente 94,76 de acurácia, precisão e recall. Os resultados demonstram a viabilidade da abordagem para manutenção preditiva de baixo custo.
- 19 July 2026
- Published by Sociedade Brasileira de Computação
- p. 84-95
Open AccessAnálise comparativa de acelerômetros MEMS de baixo custo para detecção de falhas em rolamentos usando redes neurais convolucionais
A manutenção preditiva é essencial para a confiabilidade de máquinas rotativas, nas quais falhas em rolamentos são frequentes. Este trabalho avalia o uso de acelerômetros MEMS de baixo custo na detecção de falhas por meio de Redes Neurais Convolucionais (CNNs). Os sinais de vibração foram coletados a 200 RPM em três condições: normal, falha no elemento rolante e falha na pista interna. Após pré-processamento, os dados foram convertidos em matrizes 8×8 para entrada na CNN. O modelo alcançou aproximadamente 94,76 de acurácia, precisão e recall. Os resultados demonstram a viabilidade da abordagem para manutenção preditiva de baixo custo.
- Open Access
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Open Journal of Instrumentation and Measurement
- Vol. 5, 2500614
Vibration-Based Condition Classification of ASTM C93900 Bronze Plain-Bearing Bushings Using Deep Learning
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Open Journal of Instrumentation and Measurement
- Vol. 5, 2500614
Open AccessVibration-Based Condition Classification of ASTM C93900 Bronze Plain-Bearing Bushings Using Deep Learning
- Open Access
- 6 June 2022
- Published by Research, Society and Development in Research, Society and Development
- Vol. 11 (8)
Characterization of Ti-6Al-4V titanium alloy applied in hydroxyapatite coated hip prostheses
Titanium and its alloys are widely used as biomaterials in hard tissue replacements due to their unique physiological environment responses and chemical and mechanical properties, such as corrosion resistance, fatigue resistance, and ductility. Other metals used as biomaterials have elastic modulus with values ten times higher than human bone, which can cause failure when there are impacts. Several studies report hip prosthesis failures due to fatigue. This article aims to carry out studies on the mechanical properties and fatigue resistance in an environment that simulates those of the joints of the human body, using hip prostheses manufactured with Ti 6Al 4V alloy with hydroxyapatite coating. Samples were taken from the neck region for microstructural characterization to identify grain size, inclusions, microhardness, tensile test, scanning electron microscopy, energy dispersion spectroscopy, X-ray fluorescence,e, and X-ray diffraction also performed. After applying more than 10,000,000 cycles with compressive forces ranging from -0.3 kN to -3.0 kN, no cracks were found and it was observed that the part suffered only elastic deformations.
- 6 June 2022
- Published by Research, Society and Development in Research, Society and Development
- Vol. 11 (8)
Open AccessCharacterization of Ti-6Al-4V titanium alloy applied in hydroxyapatite coated hip prostheses
Titanium and its alloys are widely used as biomaterials in hard tissue replacements due to their unique physiological environment responses and chemical and mechanical properties, such as corrosion resistance, fatigue resistance, and ductility. Other metals used as biomaterials have elastic modulus with values ten times higher than human bone, which can cause failure when there are impacts. Several studies report hip prosthesis failures due to fatigue. This article aims to carry out studies on the mechanical properties and fatigue resistance in an environment that simulates those of the joints of the human body, using hip prostheses manufactured with Ti 6Al 4V alloy with hydroxyapatite coating. Samples were taken from the neck region for microstructural characterization to identify grain size, inclusions, microhardness, tensile test, scanning electron microscopy, energy dispersion spectroscopy, X-ray fluorescence,e, and X-ray diffraction also performed. After applying more than 10,000,000 cycles with compressive forces ranging from -0.3 kN to -3.0 kN, no cracks were found and it was observed that the part suffered only elastic deformations.
- Open Access
- 9 March 2022
- Published by Research, Society and Development in Research, Society and Development
- Vol. 11 (4)
Data analyses of fatigue tests by extensometry in hip prosthesis of the Co-28Cr-6Mo alloy
ANVISA made changes to its regulations, setting new values for the fatigue tests, increasing the number of cycles that prostheses must endure without presenting failures. The standard used is ABNT NBR 7206-6:2013, in which all prostheses being commercialized must be tested in the new parameters. In this article, studies were conducted based on the requirement to revalidate the Co-26Cr-6Mo metallic alloy (ASTM F75). Microstructural characterizations (Optical and Scanning Electron Microscopies), and fatigue tests were carried out, with the aim of obtaining the mechanical behavior and features of the materials used in hip prostheses and comparing them with the standard. The grain size and inclusion contents were found to be controlled. Likewise, the prosthesis has withstand 10,000,000 cycles, and has not shown cracks, nor plastic deformations, enabling the biomedical use of this alloy according to the new regulations. Tensile test and liquid penetrant inspection were also carried out to take the parameters of the related physical properties. In the analysis with strain gauges, it was possible to detect the purely elastic deformation that occurred with the application of the load during fatigue tests, resulting in a slight variation of stress in the data acquisition system.
- 9 March 2022
- Published by Research, Society and Development in Research, Society and Development
- Vol. 11 (4)
Open AccessData analyses of fatigue tests by extensometry in hip prosthesis of the Co-28Cr-6Mo alloy
ANVISA made changes to its regulations, setting new values for the fatigue tests, increasing the number of cycles that prostheses must endure without presenting failures. The standard used is ABNT NBR 7206-6:2013, in which all prostheses being commercialized must be tested in the new parameters. In this article, studies were conducted based on the requirement to revalidate the Co-26Cr-6Mo metallic alloy (ASTM F75). Microstructural characterizations (Optical and Scanning Electron Microscopies), and fatigue tests were carried out, with the aim of obtaining the mechanical behavior and features of the materials used in hip prostheses and comparing them with the standard. The grain size and inclusion contents were found to be controlled. Likewise, the prosthesis has withstand 10,000,000 cycles, and has not shown cracks, nor plastic deformations, enabling the biomedical use of this alloy according to the new regulations. Tensile test and liquid penetrant inspection were also carried out to take the parameters of the related physical properties. In the analysis with strain gauges, it was possible to detect the purely elastic deformation that occurred with the application of the load during fatigue tests, resulting in a slight variation of stress in the data acquisition system.
- Open Access
- 1 January 2022
- Published by Editora Cubo in Tecnologia em Metalurgia, Materiais e Mineração
- Vol. 19, e2507
Influência da variação de temperatura nos aspectos microestruturais e propriedades mecânicas no bronze de alumínio-níquel UNS C63000 submetido ao processo de têmpera
Tecnol. Metal. Mater. Min., vol.19, e2507, 2022
- 1 January 2022
- Published by Editora Cubo in Tecnologia em Metalurgia, Materiais e Mineração
- Vol. 19, e2507
Open AccessInfluência da variação de temperatura nos aspectos microestruturais e propriedades mecânicas no bronze de alumínio-níquel UNS C63000 submetido ao processo de têmpera
Tecnol. Metal. Mater. Min., vol.19, e2507, 2022
- Open Access
- 1 September 2021
- Published by Elsevier in Journal of Materials Research and Technology
- Vol. 14, 2970-2981
Microstructure and fatigue properties of extruded aluminum alloys 7046 and 7108 for automotive applications
- 1 September 2021
- Published by Elsevier in Journal of Materials Research and Technology
- Vol. 14, 2970-2981
Open AccessMicrostructure and fatigue properties of extruded aluminum alloys 7046 and 7108 for automotive applications
- 1 March 2020
- Published by The Academic Society in The Academic Society Journal
- p. 4-13
The use of titanium alloy (F136) in surgical implants
Titanium has been widely used in the area of biomaterials, the segment of manufacture of products for rehabilitation goes through a constant evolution, because each year new techniques appear, new technologies that help in the development of biomaterials, these evolutions are mostly aimed at cost reduction, osseointegration, biocompatibility among other factors. The objective of this article is to carry out the analysis of the fixation screws of the femur prosthesis and hip prostheses, manufactured in titanium alloy ASTM 136. The use of titanium alloys in orthopedic, dental and aeronautical applications has increased in recent decades. The use of titanium in biomaterials is due to its singularities in the physiological environment and its favorable chemical and mechanical properties such as good resistance to corrosion, high degree of biocompatibility and low modulus of elasticity. For the fixation screws, analyzes of their resistance to torsion and the fracture surfaces of the tested samples were performed, for the analyzes were used Scanning Electron Microscopy (SEM) and semiquantitative analysis of the chemical elements by X-ray spectroscopy by dispersion in (EDS) and for the hip prosthesis, the fatigue test will be carried out according to ABNT NBR 7206-6. These tests aim to verify if both are able to be sold on the national market. With the tests completed, the results were compared with the standards in force. The results of the torsion tests are presented, where all samples met the quality requirements and the hip prostheses showed a stable behavior during the 10.000.000 million cycles, without failures during or after the tests.
- 1 March 2020
- Published by The Academic Society in The Academic Society Journal
- p. 4-13
The use of titanium alloy (F136) in surgical implants
Titanium has been widely used in the area of biomaterials, the segment of manufacture of products for rehabilitation goes through a constant evolution, because each year new techniques appear, new technologies that help in the development of biomaterials, these evolutions are mostly aimed at cost reduction, osseointegration, biocompatibility among other factors. The objective of this article is to carry out the analysis of the fixation screws of the femur prosthesis and hip prostheses, manufactured in titanium alloy ASTM 136. The use of titanium alloys in orthopedic, dental and aeronautical applications has increased in recent decades. The use of titanium in biomaterials is due to its singularities in the physiological environment and its favorable chemical and mechanical properties such as good resistance to corrosion, high degree of biocompatibility and low modulus of elasticity. For the fixation screws, analyzes of their resistance to torsion and the fracture surfaces of the tested samples were performed, for the analyzes were used Scanning Electron Microscopy (SEM) and semiquantitative analysis of the chemical elements by X-ray spectroscopy by dispersion in (EDS) and for the hip prosthesis, the fatigue test will be carried out according to ABNT NBR 7206-6. These tests aim to verify if both are able to be sold on the national market. With the tests completed, the results were compared with the standards in force. The results of the torsion tests are presented, where all samples met the quality requirements and the hip prostheses showed a stable behavior during the 10.000.000 million cycles, without failures during or after the tests.
- Open Access
- 1 March 2015
- Published by FapUNIFESP (SciELO) in Research on Biomedical Engineering
- Vol. 31 (1) , 62-69
Conception, design and development of a low-cost intelligent prosthesis for one-sided transfemoral amputees
Key words: Rehabilitation; Transfemoral amputees; Intelligent prostheses
- 1 March 2015
- Published by FapUNIFESP (SciELO) in Research on Biomedical Engineering
- Vol. 31 (1) , 62-69
Open AccessConception, design and development of a low-cost intelligent prosthesis for one-sided transfemoral amputees
Key words: Rehabilitation; Transfemoral amputees; Intelligent prostheses