MKMark Kielpinski

Mark Kielpinski

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Mark Kielpinski has a total of 12 co-authors. Here are the top co-authors by number of shared publications:

  • E. Kessler

    Institute of Photonic Technology , Albert-Einstein-Str. 9, D-07745 Jena, Germany

    1 shared publication
  • Gregor Alexander Groß

    Group of Physical Chemistry/Catalysis, Department of Natural Sciences and Mathematics, Technische Universität Ilmenau, Weimarer Str. 32, 98693 Ilmenau, Germany

    1 shared publication
  • H.-G. Meyer

    Institute of Photonic Technology , Albert-Einstein-Str. 9, D-07745 Jena, Germany

    1 shared publication
  • Jialan Cao

    Group for Physical Chemistry and Microreaction Technology, Institute for Chemistry and Bioengineering, Technische Universität Ilmenau, 98693 Ilmenau, Germany

    1 shared publication
  • Johann Michael Koehler

    Group for Physical Chemistry and Microreaction Technology, Institute for Chemistry and Bioengineering, Technische Universität Ilmenau, 98693 Ilmenau, Germany

    1 shared publication
  • Oliver Walther

    Department of Physical Chemistry and Microreaction Technologies, Institute of Chemistry and Biotechnology, Technische Universität Ilmenau, Prof.-Schmidt-Straße 26, 98693 Ilmenau, Germany

    1 shared publication

Latest Publications

  • Open Access

    Microfluidic Chamber Design for Controlled Droplet Expansion and Coalescence

    by Mark Kielpinski, Oliver Walther, Jialan Cao, Thomas Henkel, J. Michael Köhler, G. Alexander Groß

    The defined formation and expansion of droplets are essential operations for droplet-based screening assays. The volumetric expansion of droplets causes a dilution of the ingredients. Dilution is required for the generation of concentration graduation which is mandatory for many different assay protocols. Here, we describe the design of a microfluidic operation unit based on a bypassed chamber and its operation modes. The different operation modes enable the defined formation of sub-µL droplets on the one hand and the expansion of low nL to sub-µL droplets by controlled coalescence on the other. In this way the chamber acts as fluidic interface between two fluidic network parts dimensioned for different droplet volumes. Hence, channel confined droplets of about 30–40 nL from the first network part were expanded to cannel confined droplets of about 500 to about 2500 nL in the second network part. Four different operation modes were realized: (a) flow rate independent droplet formation in a self-controlled way caused by the bypassed chamber design, (b) single droplet expansion mode, (c) multiple droplet expansion mode, and (d) multiple droplet coalescence mode. The last mode was used for the automated coalescence of 12 droplets of about 40 nL volume to produce a highly ordered output sequence with individual droplet volumes of about 500 nL volume. The experimental investigation confirmed a high tolerance of the developed chamber against the variation of key parameters of the dispersed-phase like salt content, pH value and fluid viscosity. The presented fluidic chamber provides a solution for the problem of bridging different droplet volumes in a fluidic network.


  • A full optically operated magnetometer array: An experimental study

    by R. Ijsselsteijn, M. Kielpinski, S. Woetzel, T. Scholtes, E. Kessler, R. Stolz, V. Schultze, H.-G. Meyer

    We show the operation of an optically pumped magnetometer array in a 50 μT magnetic field. The various components for a fully optical and non-magnetic detector unit were constructed and evaluated, from which a prototype unit was assembled with fiber coupled electronics. In this unit the magnetometers were operated using the intensity modulated method and heated with an off-resonant laser. Calculations on the temperature distribution were used to design the magnetometer array. Different magnetometers in such a detector unit were characterized and showed identical performance. Without applying noise reduction schemes, the obtained magnetic field resolution is a factor 2.5 above the shot noise level down to frequencies of about 7 Hz.