YLYige Lin

Yige Lin

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Yige Lin has a total of 77 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Local Determination of Comb Mode Number in Remote Optical Clock Comparison

    by Hao Liu, Haochen Tian, Bingkun Lu, Qiang Wang, Yige Lin

    Optical clocks and their associated frequency comparison networks are exceptionally sensitive to microscopic physical variations and thus capable of measuring fundamental physical quantities across diverse applications. In frequency comparison networks, the optical frequency combs (OFCs) act as accurate frequency sensors designed to translate terahertz optical signals down to radio frequency signals for accurate frequency counting. The number of OFC’s comb modes that beat with clock and transfer lasers during remote frequency comparison is indispensable for the calculation of their frequency difference. In this work, with the assistance of a 1542 nm cavity-stabilized laser at Changping campus, the number of comb modes is locally determined with sufficient uncertainty by stepping the comb’s repetition rate. This approach bypasses the technical challenges of simultaneous operation of optical clocks, OFC and fiber-link noise cancelation during long-distance comparison, providing a reliable prerequisite for remote optical clock comparisons.

  • Thermal Effect of Acousto-Optic Frequency Shifter and Its Impact on Optical Metrology

    by Runmin Li, Haochen Tian, Dengfeng Dong, Yige Lin, Weihu Zhou

    Acousto-optic frequency shifter (AOFS) is the key component in optical metrology, encompassing applications such as length, velocity, and frequency measurements. The acousto-optic crystal suffers from thermal accumulation during operation, leading to significant changes in its optical and physical properties. As a result, the diffracted beam of an AOFS undergoes phase and frequency drift, degrading the measurement precision of optical metrology systems. In this letter, we evaluate the path length and optical frequency fluctuation of the $1^{\text {st}}$ -order diffracted beam passing through an AOFS due to thermal effect. Our experiment reveals linear correlation between both path length drift rate and frequency drift versus temperature drift rate. The measured proportionality factor are $0.791~\mu $ m/K and 1.019 Hz/K/s, respectively. Under thermal equilibrium conditions, AOFS-contributed noise floor in distance, velocity and frequency measurement are $\sim ~100$ pm at 100 ms averaging time, $2.5~\mu $ m/s at 1 ms averaging time, and $1.56\times 10 ^{-20}$ at 10,000 s averaging time, respectively.


  • Open Access

    Frequency-shifted f-2f interferometer for unveiling the noise performance of carrier-envelope offset in passively stabilized frequency combs

    by Haochen Tian, Yu Cai, Tao Yang, Qiang Wang, Xinqi Wang, Baike Lin, Fei Meng, Ye Li, Zhanjun Fang, Günter Steinmeyer, et al.

    The past two decades have seen rapid development of optical atomic clocks with fractional performance at 10−18 level or even below. Dissemination of optical atomic clocks into microwave domain and their intercomparisons using optical frequency combs as clockwork requires precise measurements of their carrier-envelope offset frequencies (fceo). To this end, passive stabilization to zero offset frequency has been considered as a promising approach. However, previous studies often indicate imperfections in passive stabilization schemes. Therefore, in this Letter, aiming to unveil the in-depth noise performance and origin of fceo of passively stabilized frequency combs, a frequency-shifted f-2f interferometer is presented to characterize the fceo frequency stability, frequency shift, frequency uncertainty, linewidth, and phase noise. The stability observed amounts to 2.46 × 10−17 and 4.05 × 10−20 in 1 and 10 000 s, respectively. The linewidth of fceo is 3.7 mHz, with resulting phase noise of − 40 dBrad2/Hz and −64 dBrad2/Hz at 1 and 10 Hz offset frequency, respectively. The phase noise at > 1 kHz is confirmed to be of stochastic origin through correlation analysis. The measured fceo is conclusively determined as −75(14) μHz.


  • A 6 month-long real-time time scale steered to NIM-Sr1 optical lattice clock

    by Lin Zhu, Qiang Wang, Yuzhuo Wang, Yige Lin, Dongfang Yang, Ye Li, Tao Yang, Fei Meng, Baike Lin, Haochen Tian, et al.

    NIM-Sr1 optical lattice clock has been operated intermittently for seven consecutive months with an operation uptime around 13.8%, which serves as the reference to steer a hydrogen maser for generating a real-time time scale TS(Sr1). The peak-to-peak time difference of TS(Sr1) compared to UTC is 1.8 ns within 180 d and is less than 0.5 ns within the last month, after correcting the time error induced by a time transfer link abnormality. A dedicated automation system with hardware and software is developed to monitor the operation status of NIM-Sr1, process the measurement data, and periodically predict the hydrogen maser frequency. According to the simulation results, a composite algorithm based on both Kalman filtering (KF) and weighted least squares fitting (WLSF) is utilized for generating TS(Sr1). The KF is utilized when the unavailability of NIM-Sr1 is shorter than 1 d, and the WLSF with fitting interval T fit = 30  d is utilized in other conditions leveraging the long-term predictability of the hydrogen maser. In addition, it is demonstrated by simulation and the post-processing of earlier experimental data that, a time scale with smaller time error can be achieved by shortening the WLSF interval from 30 d to about 5 d under the condition of sufficient measurement data points for reducing the statistical error.


  • Absolute frequency measurements with a robust, transportable 40Ca+ optical clock

    by Huaqing Zhang, Yao Huang, Baolin Zhang, Yanmei Hao, Mengyan Zeng, Qunfeng Chen, Yuzhuo Wang, Shiying Cao, Yige Lin, Zhanjun Fang, et al.

    We constructed a transportable 40Ca+ optical clock (with an estimated minimum systematic shift uncertainty of 1.3 × 10 − 17   and a stability of 5 × 10 − 15 / τ ) that can operate outside the laboratory. We transported it from the Innovation Academy for Precision Measurement Science and Technology, Chinese Academy of Sciences, Wuhan to the National Institute of Metrology, Beijing. The absolute frequency of the 729 nm clock transition was measured for up to 35 d by tracing its frequency to the second of International System of Units. Some improvements were implemented in the measurement process, such as the increased effective up-time of 91.3% of the 40Ca+ optical clock over a 35-day-period, the reduced statistical uncertainty of the comparison between the optical clock and hydrogen maser, and the use of longer measurement times to reduce the uncertainty of the frequency traceability link. The absolute frequency measurement of the 40Ca+ optical clock yielded a value of 411 042 129 776 400.26 (13) Hz with an uncertainty of 3.2 × 10 − 16 , which is reduced by a factor of 1.7 compared with our previous results. As a result of the increase in the operating rate of the optical clock, the accuracy of 35 d of absolute frequency measurement can be comparable to the best results of different institutions in the world based on different optical frequency measurements.


  • Preliminary study of generating a local time scale with NIM 87Sr optical lattice clock

    by Lin Zhu, Yige Lin, Yuzhuo Wang, Zhengsen Jia, Qiang Wang, Ye Li, Tao Yang, Zhanjun Fang

    A local time scale can be generated by steering flywheel clocks with state-of-the-art optical lattice clocks. This paper presents our simulations about the influence of the optical lattice clock’s operational strategies and the flywheel clock’s noise characteristics on the performance of the generated time scale. By post-processing the measured frequency difference between the optical lattice clock Sr1 and the hydrogen maser HM50 at the National Institute of Metrology (NIM), during the modified Julian date (MJD) 59029–59059, a local time scale with 0.68 ns time variation referencing to the TT(BIPM20) is demonstrated.


  • Open Access

    Traceability of optical frequency to SI second via UTC(NIM)

    by Yuzhuo Wang, Yige Lin, Yuan Gao, Aimin Zhang

    Absolute frequency measurement of an optical clock is a milestone towards the redefinition of second in the International System of Units. This work summarizes briefly the measurement of frequency ratio between an optical clock and the second, applying the frequency comparison link from UTC(NIM) to International Atomic Time. Some strategies and suggestions are proposed to reduce the uncertainty introduced by the measurement system and dead time, which guided the frequency measurement of three optical clocks at 10−16 level in the past 3 years.

  • Improved Evaluation of BBR and Collisional Frequency Shifts of NIM-Sr2 with 7.2 × 10−18 Total Uncertainty

    by Bing-Kun Lu, Zhen Sun, Tao Yang, Yi-Ge Lin, Qiang Wang, Ye Li, Fei Meng, Bai-Ke Lin, Tian-Chu Li, Zhan-Jun Fang

    NIM-Sr2 optical lattice clock has been developed on the Changping campus of National Institute of Metrology (NIM). Considering the limitations in NIM-Sr1, several improved parts have been designed including a differential pumping stage in the vacuum system, a permanent magnet Zeeman slower, water-cooled anti-Helmholtz coils, an extended viewport for Zeeman slower, etc. A clock laser with a short-time stability better than 3 × 10−16 is realized based on a self-designed 30-cm-long ultra-low expansion cavity. The systematic frequency shift has been evaluated to an uncertainty of 7.2 × 10−18, with the uncertainty of BBR shift and the collisional frequency shift being an order of magnitude lower than the last evaluation of NIM-Sr1.


  • Open Access

    A compact, transportable optical clock with 1×10−17 uncertainty and its absolute frequency measurement

    by Jian Cao, Jinbo Yuan, Shaomao Wang, Ping Zhang, Yi Yuan, Daoxin Liu, Kaifeng Cui, Sijia Chao, Hualin Shu, Yige Lin, et al.

    We report a robust, compact, and transportable optical clock (TOC-729-2) based on a trapped single 40Ca+ ion with a systematic uncertainty of 1.1×10−17 , which is limited by the black-body radiation shift uncertainty at room temperature. By comparing it with the previous transportable optical clock (TOC-729-1) similar but completely independent, the instability was measured to be better than 1.2×10−14/τ . Benefiting from the modular and integrated design, this TOC was constructed in a volume of ∼0.33 m3 excluding the controlling electronics in 19-in. racks. After being moved ∼1200 km away by express delivery, the single-ion signal was restored within 24 h. With the TOC uptime of 92% in 35-day period, the absolute frequency of the 729 nm transition of 40Ca+ was measured using a satellite link to International Atomic Time (TAI) to provide traceability to the SI second, and the result is 411 042 129 776 400.15(22) Hz, corresponding to a relative uncertainty of 5.3×10−16 .


  • A 87 Sr optical lattice clock with 2.9 × 10   − 17 uncertainty and its absolute frequency measurement

    by Yige Lin, Qiang Wang, Fei Meng, Shiying Cao, Yuzhuo Wang, Ye Li, Zhen Sun, Bingkun Lu, Tao Yang, Baike Lin, et al.

    We report the 87 Sr optical lattice clock at NIM with a clock laser referenced to a 30 cm ULE cavity. Several improvements, such as the atomic temperature and density, the lattice laser frequency stabilization, the fiber noise cancellation, etc, have been made since its first evaluation in 2015. Its systematic frequency shifts are carefully evaluated with a total relative uncertainty of 2.9 × 10 −17 . The measured absolute frequency is 429 228 004 229 873.07(0.13) Hz with a relative uncertainty of 3.1 × 10 −16 , with reference to the ensemble of primary and secondary frequency standards published in the Circular T bulletin by BIPM through a satellite link.