Heng Liu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Heng Liu has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
- Feng Zhou
College of Transportation Science & Engineering, Nanjing Tech University, Nanjing 211816, China
3 shared publications - Zhengwei Wang
College of Transportation Engineering, Nanjing Tech University, Nanjing 211816, China
2 shared publications - Zhihui Wan
Nanjing Tech Univ
2 shared publications Chan-Juan Huang
Institute of Geotechnical Engineering, Nanjing Tech University, Nanjing, China
1 shared publication- Dong Hu
College of Civil Engineering, Fuzhou University, Fuzhou 350116, China
1 shared publication - Guoliang Dai
School of Civil Engineering, Southeast University, Nanjing 211189, China
1 shared publication
Latest Publications
- Open Access
Vertical Deformation Calculation Method and In Situ Protection Design for Large-Span Suspended Box Culverts
Underground power pipelines are often encased in box culverts and buried in soil. When foundation pit excavation involves such existing pipelines, the buried box culverts can become partially suspended, risking excessive vertical deformation and requiring effective in situ protection. This study proposed analytical methods to calculate the vertical deformation of large-span box culverts under both unprotected and protected conditions. A case study of the 112 m suspended power box culverts at Yunnan Road Station on Nanjing Metro Line 5 is presented, where the methods are applied to determine the maximum allowable unsupported span and to formulate specific support and suspension protection schemes, which include a number of protection points and their spacing. Validation through ABAQUS modeling shows strong agreement among theoretical predictions, numerical simulations, and field measurements. Parametric analysis further demonstrated that the height, width, and modulus of the reinforced soil around the buried section all have a significant influence on the deformation control effectiveness. This study provides a combined theoretical framework and practical design guidelines for deformation control of large-span suspended box culverts in engineering applications.
Open AccessVertical Deformation Calculation Method and In Situ Protection Design for Large-Span Suspended Box Culverts
Underground power pipelines are often encased in box culverts and buried in soil. When foundation pit excavation involves such existing pipelines, the buried box culverts can become partially suspended, risking excessive vertical deformation and requiring effective in situ protection. This study proposed analytical methods to calculate the vertical deformation of large-span box culverts under both unprotected and protected conditions. A case study of the 112 m suspended power box culverts at Yunnan Road Station on Nanjing Metro Line 5 is presented, where the methods are applied to determine the maximum allowable unsupported span and to formulate specific support and suspension protection schemes, which include a number of protection points and their spacing. Validation through ABAQUS modeling shows strong agreement among theoretical predictions, numerical simulations, and field measurements. Parametric analysis further demonstrated that the height, width, and modulus of the reinforced soil around the buried section all have a significant influence on the deformation control effectiveness. This study provides a combined theoretical framework and practical design guidelines for deformation control of large-span suspended box culverts in engineering applications.
- Open Access
- 23 September 2025
- Published by MDPI AG in Applied Sciences
- Vol. 15 (19) , 10313
Bearing Capacity Design of Strength Composite Piles Considering Dominant Failure Modes and Calibrated Adjustment Coefficients
Significant discrepancies persist between the predicted and measured bearing capacities of Strength Composite (SC) piles in engineering practice, largely due to incomplete consideration of dominant failure modes and the absence of scientifically calibrated adjustment coefficients. Existing design specifications treat side and tip resistance inconsistently and often neglect failures induced by insufficient pile material strength, which compromises accuracy and reliability. To address these limitations, this study systematically analyzed static load test data from 159 SC piles across 44 projects. Statistical evaluation revealed clear dependencies between soil type, pile–soil interface performance, and failure mechanisms, from which stratified adjustment coefficients of side resistance and the unified adjustment coefficient of tip resistance were derived. On this basis, a new calculation method for pile capacity was developed that, for the first time, explicitly integrates material strength limitations and interface failure mechanisms into design. Validation against 112 additional test piles confirmed that over 50% of predicted-to-measured ratios approximated 1.0, and 82.1% fell within ±20%. The study proposes a calculation method for SC pile bearing capacity that is broadly applicable, simple in form, and explicitly accounts for dominant failure modes, thereby providing both theoretical rigor and engineering practicality.
- 23 September 2025
- Published by MDPI AG in Applied Sciences
- Vol. 15 (19) , 10313
Open AccessBearing Capacity Design of Strength Composite Piles Considering Dominant Failure Modes and Calibrated Adjustment Coefficients
Significant discrepancies persist between the predicted and measured bearing capacities of Strength Composite (SC) piles in engineering practice, largely due to incomplete consideration of dominant failure modes and the absence of scientifically calibrated adjustment coefficients. Existing design specifications treat side and tip resistance inconsistently and often neglect failures induced by insufficient pile material strength, which compromises accuracy and reliability. To address these limitations, this study systematically analyzed static load test data from 159 SC piles across 44 projects. Statistical evaluation revealed clear dependencies between soil type, pile–soil interface performance, and failure mechanisms, from which stratified adjustment coefficients of side resistance and the unified adjustment coefficient of tip resistance were derived. On this basis, a new calculation method for pile capacity was developed that, for the first time, explicitly integrates material strength limitations and interface failure mechanisms into design. Validation against 112 additional test piles confirmed that over 50% of predicted-to-measured ratios approximated 1.0, and 82.1% fell within ±20%. The study proposes a calculation method for SC pile bearing capacity that is broadly applicable, simple in form, and explicitly accounts for dominant failure modes, thereby providing both theoretical rigor and engineering practicality.
- Open Access
- 13 March 2023
- Published by MDPI AG in Applied Sciences
- Vol. 13 (6) , 3651
Numerical Analysis of Shield Tunnelling Breakthrough Working Shaft by Artificial Ground Freezing Method under Extreme Conditions Considering Phase Change Latent Heat
The artificial ground freezing method has been widely used in shield tunneling breakthrough working shafts. The freezing effect was mainly considered in the previous research, and the heat generation of the shield machine was not considered, which has great influence in actual engineering. In this paper, a coupling calculation model, considering phase change latent heat, is establishes that by containing the freezing process and heat generation of the shield machine, the model is verified. A numerical simulation is carried out for several working conditions that may occur in actual projects, and the following conclusions are obtained. Although the heat dissipated by the normal tunneling of the shield machine will melt the frozen soil curtain that originally meets the design requirements, the thickness of the frozen soil curtain after melting cannot reach the initial design, though it is still within the safe range. In the process of a continuous rotation working condition, the bottom and sides of a cup-shaped frozen soil curtain are partially melted in the early 6 day stay of the shield machine, and the thickness is reduced to a relatively stable value of 0.8 m. In a temporary shutdown working condition, when the contact surface temperature between the shield machine shell and the frozen soil drops to −12 °C after almost 4 days of shutdown, the shield machine may not keep tunneling forward due to the freezing effect. The research results will benefit the freezing design and management of the shield tunneling breakthrough working shaft under extreme conditions.
- 13 March 2023
- Published by MDPI AG in Applied Sciences
- Vol. 13 (6) , 3651
Open AccessNumerical Analysis of Shield Tunnelling Breakthrough Working Shaft by Artificial Ground Freezing Method under Extreme Conditions Considering Phase Change Latent Heat
The artificial ground freezing method has been widely used in shield tunneling breakthrough working shafts. The freezing effect was mainly considered in the previous research, and the heat generation of the shield machine was not considered, which has great influence in actual engineering. In this paper, a coupling calculation model, considering phase change latent heat, is establishes that by containing the freezing process and heat generation of the shield machine, the model is verified. A numerical simulation is carried out for several working conditions that may occur in actual projects, and the following conclusions are obtained. Although the heat dissipated by the normal tunneling of the shield machine will melt the frozen soil curtain that originally meets the design requirements, the thickness of the frozen soil curtain after melting cannot reach the initial design, though it is still within the safe range. In the process of a continuous rotation working condition, the bottom and sides of a cup-shaped frozen soil curtain are partially melted in the early 6 day stay of the shield machine, and the thickness is reduced to a relatively stable value of 0.8 m. In a temporary shutdown working condition, when the contact surface temperature between the shield machine shell and the frozen soil drops to −12 °C after almost 4 days of shutdown, the shield machine may not keep tunneling forward due to the freezing effect. The research results will benefit the freezing design and management of the shield tunneling breakthrough working shaft under extreme conditions.
- 27 October 2022
- Published by Springer Nature in Applied Geophysics
- Vol. 20 (4) , 447-459
A mesh-free finite-difference scheme for frequency-domain acoustic wave simulation with topography
- 27 October 2022
- Published by Springer Nature in Applied Geophysics
- Vol. 20 (4) , 447-459
A mesh-free finite-difference scheme for frequency-domain acoustic wave simulation with topography
- Open Access
- 7 March 2022
- Published by MDPI AG in Applied Sciences
- Vol. 12 (5) , 2731
Axial Bearing Mechanism of Post-Grouted Piles in Calcareous Sand
Post-grouted piles, as a foundation form for large-span and large-scale structures on calcareous sand, are expected to provide a high bearing capacity, but research on the response of post-grouted piles subjected to axial load in calcareous sand is still in the exploratory stage. In this paper, a model test is constructed for static pressure piles in calcareous sand under axial loading. The response of axial compressive piles, with and without post-grouting, in calcareous sand were investigated, and the test results were compared with those of axial compressive piles, with and without post-grouting, in siliceous sand. The influence of post-side-grouting on the response of a single pile subjected to axial compressive load in calcareous sand and its bearing mechanism were further analyzed. The results show that the change in shaft resistance, caused by the lateral extrusion of calcareous sand, is less than the negative effect caused by particle breakage during pile driving, so single piles without post-grouting in calcareous sand exhibit weaker axial bearing behavior than that in siliceous sand. A single pile with post-side-grouting in calcareous sand can provide a higher bearing capacity by increasing the shaft resistance and tip resistance compared with a single pile without post-side-grouting, and the increased ratio of the bearing capacity of piles, after grouting in calcareous sand, is better than that of piles in siliceous sand. Post-side-grouting can not only strengthen the surrounding soil by the solidification effect of injected cement grout, but it can also have a strengthening effect on the tip resistance. In addition, ideal-geometry grouting has more obvious advantages in improving the bearing behavior of pile foundations than annular point grouting, and higher stability in improving the bearing properties of pile foundations is evident for ideal-geometry grouting. Therefore, it is suggested that a directional grouting device should be adopted in actual projects in the future to form a more stable pile-soil interaction system and to expand the application prospect of pile foundations in calcareous sand.
- 7 March 2022
- Published by MDPI AG in Applied Sciences
- Vol. 12 (5) , 2731
Open AccessAxial Bearing Mechanism of Post-Grouted Piles in Calcareous Sand
Post-grouted piles, as a foundation form for large-span and large-scale structures on calcareous sand, are expected to provide a high bearing capacity, but research on the response of post-grouted piles subjected to axial load in calcareous sand is still in the exploratory stage. In this paper, a model test is constructed for static pressure piles in calcareous sand under axial loading. The response of axial compressive piles, with and without post-grouting, in calcareous sand were investigated, and the test results were compared with those of axial compressive piles, with and without post-grouting, in siliceous sand. The influence of post-side-grouting on the response of a single pile subjected to axial compressive load in calcareous sand and its bearing mechanism were further analyzed. The results show that the change in shaft resistance, caused by the lateral extrusion of calcareous sand, is less than the negative effect caused by particle breakage during pile driving, so single piles without post-grouting in calcareous sand exhibit weaker axial bearing behavior than that in siliceous sand. A single pile with post-side-grouting in calcareous sand can provide a higher bearing capacity by increasing the shaft resistance and tip resistance compared with a single pile without post-side-grouting, and the increased ratio of the bearing capacity of piles, after grouting in calcareous sand, is better than that of piles in siliceous sand. Post-side-grouting can not only strengthen the surrounding soil by the solidification effect of injected cement grout, but it can also have a strengthening effect on the tip resistance. In addition, ideal-geometry grouting has more obvious advantages in improving the bearing behavior of pile foundations than annular point grouting, and higher stability in improving the bearing properties of pile foundations is evident for ideal-geometry grouting. Therefore, it is suggested that a directional grouting device should be adopted in actual projects in the future to form a more stable pile-soil interaction system and to expand the application prospect of pile foundations in calcareous sand.