Zhengwei Wang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Zhengwei Wang has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Heng Liu
College of Transportation Engineering, Nanjing Tech University, Nanjing 211816, China
2 shared publications - Dong Hu
College of Civil Engineering, Fuzhou University, Fuzhou 350116, China
1 shared publication - Feng Zhou
College of Transportation Science & Engineering, Nanjing Tech University, Nanjing 211816, China
1 shared publication - Lei Guo
College of Transportation Engineering, Nanjing Tech University, Nanjing 211800, China
1 shared publication - Lei Guo
College of Transportation Engineering, Nanjing Tech University, Nanjing 211816, China
1 shared publication - Mingjie Xu
College of Transportation Engineering, Nanjing Tech University, Nanjing 211816, China
1 shared publication
Latest Publications
- Open Access
Vertical Deformation Calculation Method and In Situ Protection Design for Large-Span Suspended Box Culverts
Underground power pipelines are often encased in box culverts and buried in soil. When foundation pit excavation involves such existing pipelines, the buried box culverts can become partially suspended, risking excessive vertical deformation and requiring effective in situ protection. This study proposed analytical methods to calculate the vertical deformation of large-span box culverts under both unprotected and protected conditions. A case study of the 112 m suspended power box culverts at Yunnan Road Station on Nanjing Metro Line 5 is presented, where the methods are applied to determine the maximum allowable unsupported span and to formulate specific support and suspension protection schemes, which include a number of protection points and their spacing. Validation through ABAQUS modeling shows strong agreement among theoretical predictions, numerical simulations, and field measurements. Parametric analysis further demonstrated that the height, width, and modulus of the reinforced soil around the buried section all have a significant influence on the deformation control effectiveness. This study provides a combined theoretical framework and practical design guidelines for deformation control of large-span suspended box culverts in engineering applications.
Open AccessVertical Deformation Calculation Method and In Situ Protection Design for Large-Span Suspended Box Culverts
Underground power pipelines are often encased in box culverts and buried in soil. When foundation pit excavation involves such existing pipelines, the buried box culverts can become partially suspended, risking excessive vertical deformation and requiring effective in situ protection. This study proposed analytical methods to calculate the vertical deformation of large-span box culverts under both unprotected and protected conditions. A case study of the 112 m suspended power box culverts at Yunnan Road Station on Nanjing Metro Line 5 is presented, where the methods are applied to determine the maximum allowable unsupported span and to formulate specific support and suspension protection schemes, which include a number of protection points and their spacing. Validation through ABAQUS modeling shows strong agreement among theoretical predictions, numerical simulations, and field measurements. Parametric analysis further demonstrated that the height, width, and modulus of the reinforced soil around the buried section all have a significant influence on the deformation control effectiveness. This study provides a combined theoretical framework and practical design guidelines for deformation control of large-span suspended box culverts in engineering applications.
- Open Access
- 23 September 2025
- Published by MDPI AG in Applied Sciences
- Vol. 15 (19) , 10313
Bearing Capacity Design of Strength Composite Piles Considering Dominant Failure Modes and Calibrated Adjustment Coefficients
Significant discrepancies persist between the predicted and measured bearing capacities of Strength Composite (SC) piles in engineering practice, largely due to incomplete consideration of dominant failure modes and the absence of scientifically calibrated adjustment coefficients. Existing design specifications treat side and tip resistance inconsistently and often neglect failures induced by insufficient pile material strength, which compromises accuracy and reliability. To address these limitations, this study systematically analyzed static load test data from 159 SC piles across 44 projects. Statistical evaluation revealed clear dependencies between soil type, pile–soil interface performance, and failure mechanisms, from which stratified adjustment coefficients of side resistance and the unified adjustment coefficient of tip resistance were derived. On this basis, a new calculation method for pile capacity was developed that, for the first time, explicitly integrates material strength limitations and interface failure mechanisms into design. Validation against 112 additional test piles confirmed that over 50% of predicted-to-measured ratios approximated 1.0, and 82.1% fell within ±20%. The study proposes a calculation method for SC pile bearing capacity that is broadly applicable, simple in form, and explicitly accounts for dominant failure modes, thereby providing both theoretical rigor and engineering practicality.
- 23 September 2025
- Published by MDPI AG in Applied Sciences
- Vol. 15 (19) , 10313
Open AccessBearing Capacity Design of Strength Composite Piles Considering Dominant Failure Modes and Calibrated Adjustment Coefficients
Significant discrepancies persist between the predicted and measured bearing capacities of Strength Composite (SC) piles in engineering practice, largely due to incomplete consideration of dominant failure modes and the absence of scientifically calibrated adjustment coefficients. Existing design specifications treat side and tip resistance inconsistently and often neglect failures induced by insufficient pile material strength, which compromises accuracy and reliability. To address these limitations, this study systematically analyzed static load test data from 159 SC piles across 44 projects. Statistical evaluation revealed clear dependencies between soil type, pile–soil interface performance, and failure mechanisms, from which stratified adjustment coefficients of side resistance and the unified adjustment coefficient of tip resistance were derived. On this basis, a new calculation method for pile capacity was developed that, for the first time, explicitly integrates material strength limitations and interface failure mechanisms into design. Validation against 112 additional test piles confirmed that over 50% of predicted-to-measured ratios approximated 1.0, and 82.1% fell within ±20%. The study proposes a calculation method for SC pile bearing capacity that is broadly applicable, simple in form, and explicitly accounts for dominant failure modes, thereby providing both theoretical rigor and engineering practicality.