Fubin Pang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Fubin Pang has a total of 26 co-authors. Here are the top co-authors by number of shared publications:
Yu Liu
State Grid Jiangsu Electric Power Co., LTD. Research Institute, Nanjing 211103, China
3 shared publicationsJianfei Ji
State Grid Jiangsu Electric Power Co., LTD. Research Institute, Nanjing 211103, China
2 shared publications- Li Xia
Huazhong University of Science and Technology
2 shared publications Chi Zhang
Relay and Protection Department State Grid Jiangsu Electric Power Co. Ltd. Research Institute Nanjing People's Republic of China
1 shared publicationDong Xu
School of Electrical & Automation Engineering, Nanjing Normal University, Nanjing 210046, China
1 shared publication- Hui Hou
School of Automation, Wuhan University of Technology, Wuhan, China
1 shared publication
Latest Publications
- Open Access
Passive Time-Division Multiplexing Fiber Optic Sensor for Magnetic Field Detection Applications in Current Introduction
Under the dual impetus of the “Dual Carbon” goals and the construction of smart grids, the development of new energy power infrastructure has been fully realized. The All-Fiber Optical Current Transformer (FOCT), leveraging its unique advantages, is in the process of supplanting traditional current transformers to become the core component of power system monitoring equipment. Currently, to achieve higher precision and stability in magnetic field or current detection, FOCT structures frequently incorporate active components such as Y-waveguides and phase modulators, and closed-loop feedback systems are often used in demodulation. This has led to issues of high cost, complex demodulation, and difficult maintenance, significantly hindering the further advancement of FOCTs. Addressing the problems of high cost and complex demodulation, this paper proposes a passive multiplexing structure that achieves time-domain multiplexing of pulsed sensing signals, designs a corresponding intensity demodulation algorithm, and applies this structure to FOCTs. This enables low-cost, simple-demodulation current sensing, which can also be utilized for magnetic field detection, showcasing vast application potential.
Open AccessPassive Time-Division Multiplexing Fiber Optic Sensor for Magnetic Field Detection Applications in Current Introduction
Under the dual impetus of the “Dual Carbon” goals and the construction of smart grids, the development of new energy power infrastructure has been fully realized. The All-Fiber Optical Current Transformer (FOCT), leveraging its unique advantages, is in the process of supplanting traditional current transformers to become the core component of power system monitoring equipment. Currently, to achieve higher precision and stability in magnetic field or current detection, FOCT structures frequently incorporate active components such as Y-waveguides and phase modulators, and closed-loop feedback systems are often used in demodulation. This has led to issues of high cost, complex demodulation, and difficult maintenance, significantly hindering the further advancement of FOCTs. Addressing the problems of high cost and complex demodulation, this paper proposes a passive multiplexing structure that achieves time-domain multiplexing of pulsed sensing signals, designs a corresponding intensity demodulation algorithm, and applies this structure to FOCTs. This enables low-cost, simple-demodulation current sensing, which can also be utilized for magnetic field detection, showcasing vast application potential.
- 4 March 2025
- Published by Springer Nature
- p. 304-311
Research on the Failure Mode of FOCT Using Fault Tree Analysis Method
- 4 March 2025
- Published by Springer Nature
- p. 304-311
Research on the Failure Mode of FOCT Using Fault Tree Analysis Method
- Open Access
- 6 July 2023
- Published by River Publishers in Applied Computational Electromagnetics Society Journal (ACES)
- Vol. 38 (2) , 80–90
Analyze the Crosstalk of Multi-core Twisted Wires and the Effect of Non-matched Impedance Based on BSAS-BPNN Algorithm
In this paper, a multi-core twisted wire model with random non-uniform twists is established. The random combination of complete and non-complete pitch sections is used to accurately simulate the randomness of actual multi-core twisted wires. On the basis of the model, the cross section of the cascaded MTL is obtained, and a neural network algorithm is used to describe the complex relationship between the arbitrary position of the multi-core twisted wires and the unit length parameters. The unit length parameters at any position are obtained by cross section rotational transformation and random transposition transformation between conductors. Finally, the crosstalk in electromagnetic compatibility performance is calculated, and different termination impedances are analyzed. The results show that the crosstalk of multi-core twisted wires is susceptible to the effects of twisting and termination impedance at high frequencies, and the reliability of the proposed method is verified by comparison with full-wave simulation.
- 6 July 2023
- Published by River Publishers in Applied Computational Electromagnetics Society Journal (ACES)
- Vol. 38 (2) , 80–90
Open AccessAnalyze the Crosstalk of Multi-core Twisted Wires and the Effect of Non-matched Impedance Based on BSAS-BPNN Algorithm
In this paper, a multi-core twisted wire model with random non-uniform twists is established. The random combination of complete and non-complete pitch sections is used to accurately simulate the randomness of actual multi-core twisted wires. On the basis of the model, the cross section of the cascaded MTL is obtained, and a neural network algorithm is used to describe the complex relationship between the arbitrary position of the multi-core twisted wires and the unit length parameters. The unit length parameters at any position are obtained by cross section rotational transformation and random transposition transformation between conductors. Finally, the crosstalk in electromagnetic compatibility performance is calculated, and different termination impedances are analyzed. The results show that the crosstalk of multi-core twisted wires is susceptible to the effects of twisting and termination impedance at high frequencies, and the reliability of the proposed method is verified by comparison with full-wave simulation.
- 15 December 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Journal of Lightwave Technology
- Vol. 39 (7) , 2187-2193
Self-Compensative Fiber Optic Current Sensor
The measurement accuracy of fiber optic current sensors (FOCS) is closely related to the stability of Verdet constant and the polarization characteristic of the sensing coils, which are easily influenced by environmental disturbance. In this paper, a self-compensative fiber optic current sensor (SFOCS) with two sensing heads made of single mode fibers is designed and demonstrated. Utilizing sensing and compensative unit as well as a close-loop system, variation of Verdet constant and birefringence is compensated. We numerically calculate the output signal of SFOCS with temperature varying from —30°C to 75°C and simulate the situation where SFOCS is affected by the circular and linear birefringence from the environment, and the results confirm that well designed SFOCS is completely temperature-and vibration-independent. Additionally, in order to achieve the ideal compensation, H function of SFOCS related to birefringence and the current to be measured is introduced and deeply studied. Moreover, we discuss the measurement errors of SFOCS caused by the difference between two sensing heads such as the coupling ratio, the linear and circular birefringence, and we calculate the acceptable error range, within which SFOCS can meet the class 0.2 standard.
- 15 December 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Journal of Lightwave Technology
- Vol. 39 (7) , 2187-2193
Self-Compensative Fiber Optic Current Sensor
The measurement accuracy of fiber optic current sensors (FOCS) is closely related to the stability of Verdet constant and the polarization characteristic of the sensing coils, which are easily influenced by environmental disturbance. In this paper, a self-compensative fiber optic current sensor (SFOCS) with two sensing heads made of single mode fibers is designed and demonstrated. Utilizing sensing and compensative unit as well as a close-loop system, variation of Verdet constant and birefringence is compensated. We numerically calculate the output signal of SFOCS with temperature varying from —30°C to 75°C and simulate the situation where SFOCS is affected by the circular and linear birefringence from the environment, and the results confirm that well designed SFOCS is completely temperature-and vibration-independent. Additionally, in order to achieve the ideal compensation, H function of SFOCS related to birefringence and the current to be measured is introduced and deeply studied. Moreover, we discuss the measurement errors of SFOCS caused by the difference between two sensing heads such as the coupling ratio, the linear and circular birefringence, and we calculate the acceptable error range, within which SFOCS can meet the class 0.2 standard.
- Open Access
- 15 April 2020
- Published by Hindawi Limited in Mathematical Problems in Engineering
- Vol. 2020, 1-10
Fault Mechanism of Fiber Optical Current Transformer Based on Signal Processing Method
The fiber optical current transformer (FOCT) with sine wave modulation has been widely used in the DC transmission project, while its fault rate is much higher than that of an electromagnetic current transformer, which seriously threatens the safe operation of power grid. In order to investigate the fault mechanism of FOCT, the output signal model of the FOCT photodetector is established, and its basic methods of modulation and demodulation are analyzed to explore the influencing factors of the signal processing method used in the calculation of measured current. It is found that the reduction of the second harmonic component in the photodetector output is the root cause of FOCT fault, and the optical path, modulation signal amplitude, and measured current are important factors affecting the second harmonic component. The influencing law of three factors on the second harmonic component is calculated by simulation and the characteristic differences between them are given. Finally, the fault simulation test of FOCT light intensity and a modulation circuit were carried out in the laboratory, and the results verify the correctness of theoretical analysis. The research in this paper provides reference for fault analysis and reliability improvement of FOCT.
- 15 April 2020
- Published by Hindawi Limited in Mathematical Problems in Engineering
- Vol. 2020, 1-10
Open AccessFault Mechanism of Fiber Optical Current Transformer Based on Signal Processing Method
The fiber optical current transformer (FOCT) with sine wave modulation has been widely used in the DC transmission project, while its fault rate is much higher than that of an electromagnetic current transformer, which seriously threatens the safe operation of power grid. In order to investigate the fault mechanism of FOCT, the output signal model of the FOCT photodetector is established, and its basic methods of modulation and demodulation are analyzed to explore the influencing factors of the signal processing method used in the calculation of measured current. It is found that the reduction of the second harmonic component in the photodetector output is the root cause of FOCT fault, and the optical path, modulation signal amplitude, and measured current are important factors affecting the second harmonic component. The influencing law of three factors on the second harmonic component is calculated by simulation and the characteristic differences between them are given. Finally, the fault simulation test of FOCT light intensity and a modulation circuit were carried out in the laboratory, and the results verify the correctness of theoretical analysis. The research in this paper provides reference for fault analysis and reliability improvement of FOCT.
- Open Access
- 6 February 2019
- Published by Institution of Engineering and Technology (IET) in The Journal of Engineering
- Vol. 2019 (16) , 3337-3340
Transforming characteristics of the Rogowski coil current transformer with a digital integrator for high‐frequency signals
The Rogowski coil current transformer is widely used in intelligent substations for its rapid response, wide bandwidth measurement, and non‐magnetic saturation. In most cases, it works with a digital integrator to restore the differential signal output by the coil. However, its output waveform can be deformed when transforming high‐frequency signals generated in the transient process of the power system. The working process of the Rogowski coil current transformer is presented, including Rogowski coil head transferring, analogue filter filtering, analogue‐to‐digital converter sampling, and digital integrator restoring. The reason for the waveform deformation when transforming high‐frequency signals is investigated by theoretical derivation. In order to show the waveform deformation phenomenon, an experiment is devised and the results output by the Rogowski coil transformer and low power current transformer are compared and analysed. Several measures to improve the output waveform deformation are proposed, such as increasing the sampling rate of the converter, decreasing the cut‐off frequency of the filter, or replacing the digital integrator with the analogue integrator. The researches provide important guidelines for the application of the Rogowski coil current transformer with the digital integrator in the case of frequency aliasing.
- 6 February 2019
- Published by Institution of Engineering and Technology (IET) in The Journal of Engineering
- Vol. 2019 (16) , 3337-3340
Open AccessTransforming characteristics of the Rogowski coil current transformer with a digital integrator for high‐frequency signals
The Rogowski coil current transformer is widely used in intelligent substations for its rapid response, wide bandwidth measurement, and non‐magnetic saturation. In most cases, it works with a digital integrator to restore the differential signal output by the coil. However, its output waveform can be deformed when transforming high‐frequency signals generated in the transient process of the power system. The working process of the Rogowski coil current transformer is presented, including Rogowski coil head transferring, analogue filter filtering, analogue‐to‐digital converter sampling, and digital integrator restoring. The reason for the waveform deformation when transforming high‐frequency signals is investigated by theoretical derivation. In order to show the waveform deformation phenomenon, an experiment is devised and the results output by the Rogowski coil transformer and low power current transformer are compared and analysed. Several measures to improve the output waveform deformation are proposed, such as increasing the sampling rate of the converter, decreasing the cut‐off frequency of the filter, or replacing the digital integrator with the analogue integrator. The researches provide important guidelines for the application of the Rogowski coil current transformer with the digital integrator in the case of frequency aliasing.
- Open Access
- 6 December 2018
- Published by Institution of Engineering and Technology (IET) in The Journal of Engineering
- Vol. 2019 (16) , 1144-1148
Diagnostic analysis and protective measures of transient ground potential rise in a 1000 kv UHV substation
With the continuous expansion of power grid capacity and growth of voltage levels, the transient ground potential rise (GPR) caused by the switchgear operation has become great threaten to the safety of the grid. In the startup operation of 500 kV part of Taizhou 1000 kV ultra‐high voltage (UHV) substation, the electromagnetic lock installed in the switchgear filed was broken by the GPR in case of switchgear operation. There are two possible transmission paths of the GPR, one is the ground copper bar connecting the ground and the other is the control cable connecting the control cabinet and electromagnetic lock. In order to find out the transmission path of the electromagnetic disturbance, the experiment is carried out to distinguish the two possible paths. The waveform of the GPR in case of switchgear operation from different measuring points are recorded and compared, the results are analysed by comparing the signal characteristics and the transmission path is eventually diagnosed. Finally, the protective measures are proposed by wrapping the control wires with the conductive metal cube to reduce the influences of GPR. The outcomes in the study provide beneficial methods to analyse the GPR disturbance and positive guidance for the protection of locally installed equipment.
- 6 December 2018
- Published by Institution of Engineering and Technology (IET) in The Journal of Engineering
- Vol. 2019 (16) , 1144-1148
Open AccessDiagnostic analysis and protective measures of transient ground potential rise in a 1000 kv UHV substation
With the continuous expansion of power grid capacity and growth of voltage levels, the transient ground potential rise (GPR) caused by the switchgear operation has become great threaten to the safety of the grid. In the startup operation of 500 kV part of Taizhou 1000 kV ultra‐high voltage (UHV) substation, the electromagnetic lock installed in the switchgear filed was broken by the GPR in case of switchgear operation. There are two possible transmission paths of the GPR, one is the ground copper bar connecting the ground and the other is the control cable connecting the control cabinet and electromagnetic lock. In order to find out the transmission path of the electromagnetic disturbance, the experiment is carried out to distinguish the two possible paths. The waveform of the GPR in case of switchgear operation from different measuring points are recorded and compared, the results are analysed by comparing the signal characteristics and the transmission path is eventually diagnosed. Finally, the protective measures are proposed by wrapping the control wires with the conductive metal cube to reduce the influences of GPR. The outcomes in the study provide beneficial methods to analyse the GPR disturbance and positive guidance for the protection of locally installed equipment.