Transforming characteristics of the Rogowski coil current transformer with a digital integrator for high‐frequency signals
Authors:
Open Access
- 6 February 2019
- journal article
- research article
- Published by Institution of Engineering and Technology (IET) in The Journal of Engineering
- Vol. 2019 (16) , 3337-3340
Abstract
The Rogowski coil current transformer is widely used in intelligent substations for its rapid response, wide bandwidth measurement, and non‐magnetic saturation. In most cases, it works with a digital integrator to restore the differential signal output by the coil. However, its output waveform can be deformed when transforming high‐frequency signals generated in the transient process of the power system. The working process of the Rogowski coil current transformer is presented, including Rogowski coil head transferring, analogue filter filtering, analogue‐to‐digital converter sampling, and digital integrator restoring. The reason for the waveform deformation when transforming high‐frequency signals is investigated by theoretical derivation. In order to show the waveform deformation phenomenon, an experiment is devised and the results output by the Rogowski coil transformer and low power current transformer are compared and analysed. Several measures to improve the output waveform deformation are proposed, such as increasing the sampling rate of the converter, decreasing the cut‐off frequency of the filter, or replacing the digital integrator with the analogue integrator. The researches provide important guidelines for the application of the Rogowski coil current transformer with the digital integrator in the case of frequency aliasing.Keywords
This publication has 12 references indexed in Scilit:
- Traceable calibrations of Rogowski coils at high AC currentsIEEE Instrumentation & Measurement Magazine, 2015
- Development of a shunt lightning current measuring system using a Rogowski coilElectric Power Systems Research, 2015
- The Rogowski Coil Principles and Applications: A ReviewIEEE Sensors Journal, 2014
- Effect of geometrical parameters on high frequency performance of Rogowski coil for partial discharge measurementsMeasurement, 2014
- Investigation on Rogowski coil performance for structuring its design methodologyIET Science, Measurement & Technology, 2013
- Performance Improvement of Slow-Wave Rogowski Coils for High Impulse Current MeasurementIEEE Sensors Journal, 2012
- Coaxial-Cable Wound Rogowski Coils for Measuring Large-Magnitude Short-Duration Current PulsesIEEE Transactions on Instrumentation and Measurement, 2012
- Critical Parameters for Mutual Inductance Between Rogowski Coil and Primary ConductorIEEE Transactions on Instrumentation and Measurement, 2010
- High-Frequency Model of the Rogowski Coil With a Small Number of TurnsIEEE Transactions on Instrumentation and Measurement, 2007