LFLexiaozi Fan

Lexiaozi Fan

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Lexiaozi Fan has a total of 106 co-authors. Here are the top co-authors by number of shared publications:

  • Daniel Kim

    Department of Radiology, Northwestern University Feinberg School of Medicine, 737 N Michigan Ave, Ste 1600, Chicago, IL 60611

    8 shared publications
  • Daniel C. Lee

    Department of Radiology, Northwestern University Feinberg School of Medicine, 737 N Michigan Ave, Ste 1600, Chicago, IL 60611

    5 shared publications
  • Daniel C. Lee

    Division of Cardiology, Department of Medicine Northwestern University Feinberg School of Medicine Chicago Illinois USA

    4 shared publications
  • James C. Carr

    4 shared publications
  • KyungPyo Hong

    Department of Radiology, Northwestern University Feinberg School of Medicine, 737 N Michigan Ave, Ste 1600, Chicago, IL 60611

    4 shared publications
  • Benjamin H. Freed

    Division of Cardiology, Department of Internal Medicine, Northwestern University Feinberg School of Medicine, Chicago, Ill

    3 shared publications

Latest Publications

  • Open Access

    Cardiovascular MRI–based Biventricular Perfusion Assessment in Two Patients with Chronic Thromboembolic Pulmonary Hypertension Undergoing Pulmonary Thromboendarterectomy

    by Lexiaozi Fan, María Davó-Jiménez, Brandon C. Benefield, Nour Beydoun, David Dushfunian, Sebastian Cohn, Michael Cuttica, Ruben Mylvaganam, S. Chris Malaisrie, Stephen Chiu, et al.

    Chronic thromboembolic pulmonary hypertension (CTEPH) can lead to right ventricular (RV) ischemia and dysfunction due to chronic pulmonary artery obstruction and increased afterload. While cardiovascular MRI (CMR) enables noninvasive assessment of myocardial perfusion, its role in CTEPH remains unclear. The authors report adenosine stress perfusion CMR findings from two patients with CTEPH before and after pulmonary thromboendarterectomy (PTE). Both showed reduced biventricular perfusion before PTE; one demonstrated post-PTE improvement. Perfusion findings aligned with invasive hemodynamics, suggesting that CMR-derived myocardial perfusion reserve may serve as a valuable tool for assessing treatment response and RV pathophysiologic characteristics in CTEPH. Keywords: Cardiac, Pulmonary Arteries, Chronic Thromboembolic Pulmonary Hypertension, Pulmonary Thromboendarterectomy, Quantitative Perfusion Cardiovascular MRI, Myocardial Blood Flow, Myocardial Perfusion Reserve Supplemental material is available for this article. © RSNA, 2025


  • Open Access

    Highly Accelerated Real-time Cine MRI Pulse Sequence for Cardiac Implantable Electronic Devices and Arrhythmias

    by Dima Bishara, Kyungpyo Hong, María Davó-Jiménez, Jeremy D. Collins, Cagdas Topel, Lexiaozi Fan, Roberto Sarnari, Bradley K. Knight, Daniel C. Lee, Daniel Kim

    A 32-fold accelerated real-time cine MRI sequence (radial sampling) demonstrated better temporal resolution and image quality than a 16-fold sequence (Cartesian sampling) in patients with cardiac implantable electronic devices and arrhythmias.


  • Open Access

    Pulmonary Transit Time Can Be Accurately Quantified From Non‐Arterial Input Function Series in First‐Pass Cardiac Perfusion MRI

    by Mingyue Zhao, Lexiaozi Fan, Kyungpyo Hong, Benjamin H. Freed, Jacqueline Urban, Kelvin Chow, Li‐Yueh Hsu, Daniel C. Lee, Daniel Kim

    Purpose: Previous studies suggested that arterial‐input‐function (AIF) images are necessary to avoid signal saturation for pulmonary transit time (PTT) measurements. This study challenges that notion by investigating whether PTT can be accurately measured using blood pool signals from myocardial enhancement (non‐AIF) images during resting first‐pass perfusion MRI. Methods: This retrospective study included 108 patients, 47 scanned using a research radial perfusion sequence, and 61 scanned with a prototype Cartesian quantitative perfusion (qPerf) sequence with inline PTT calculation. An automated pipeline was developed to compute PTT measurements from blood pool signals extracted from both AIF and non‐AIF images, as well as from gadolinium concentration curves of the AIF images, using three methods: peak‐to‐peak timing, area‐under‐the‐curve (AUC) derived centroids, and curve‐fitting derived centroids. Results: Peak‐to‐peak PTT showed low bias (0.10–0.56 s; [1.4%–7.4%] of the mean), wide limits of agreement (5.71–7.42 s; [74.5%–109.8%]). In contrast, centroid‐based methods, using both AUC and curve‐fitting approaches, consistently yielded low bias (< 0.49 s; < 6.3%), narrower limits of agreement (1.83–2.84 s; 25.2%–36.8%). These findings indicate that centroid methods offer more precise and reliable PTT estimation across both radial perfusion and qPerf datasets. Conclusions: PTT can be derived accurately from non‐AIF images using either the AUC or curve‐fitting centroid‐to‐centroid method.

  • Extreme cardiac MRI analysis under respiratory motion: Results of the CMRxMotion challenge

    by Kang Wang, Chen Qin, Zhang Shi, Haoran Wang, Xiwen Zhang, Chen Chen, Cheng Ouyang, Chengliang Dai, Yuanhan Mo, Chenchen Dai, et al.


  • Open Access

    Myocardial blood flow quantification in patients with an implanted cardiodefibrillator during stress and at rest using a wideband perfusion pulse sequence: an initial feasibility study

    by Lexiaozi Fan, Maria Davo Jimenez, Dima Bishara, Jacqueline Urban, Kyungpyo Hong, Austin E. Culver, Jeremy D. Collins, Li-Yueh Hsu, Shuo Wang, Amit R. Patel, et al.

  • Ultra-rapid, Free-breathing, Real-time Cardiac Cine MRI Using GRASP Amplified with View Sharing and KWIC Filtering

    by Lexiaozi Fan, KyungPyo Hong, Bradley D. Allen, Rupsa Paul, James C. Carr, Sarah Zhang, Rod Passman, Joshua D. Robinson, Daniel C. Lee, Cynthia K. Rigsby, et al.

    Purpose To achieve ultra-high temporal resolution (approximately 20 msec) in free-breathing, real-time cardiac cine MRI using golden-angle radial sparse parallel (GRASP) reconstruction amplified with view sharing (VS) and k-space-weighted image contrast (KWIC) filtering. Materials and Methods Fourteen pediatric patients with congenital heart disease (mean age [SD], 9 years ± 2; 13 male) and 10 adult patients with arrhythmia (mean age, 62 years ± 8; nine male) who underwent both standard breath-hold cine and free-breathing real-time cine using GRASP were retrospectively identified. To achieve high temporal resolution, each time frame was reconstructed using six radial spokes, corresponding to acceleration factors ranging from 24 to 32. To compensate for loss in spatial resolution resulting from over-regularization in GRASP, VS and KWIC filtering were incorporated. The blur metric, visual image quality scores, and biventricular parameters were compared between clinical and real-time cine images. Results In pediatric patients, the incorporation of VS and KWIC into GRASP (ie, GRASP + VS + KWIC) produced significantly (P < .05) sharper x-y-t (blur metric: 0.36 ± 0.03, 0.41 ± 0.03, 0.48 ± 0.03, respectively) and x-y-f (blur metric: 0.28 ± 0.02, 0.31 ± 0.03, 0.37 ± 0.03, respectively) component images compared with GRASP + VS and conventional GRASP. Only the noise score differed significantly between GRASP + VS + KWIC and clinical cine; all visual scores were above the clinically acceptable (3.0) cutoff point. Biventricular volumetric parameters strongly correlated (R2 > 0.85) between clinical and real-time cine images reconstructed with GRASP + VS + KWIC and were in good agreement (relative error < 6% for all parameters). In adult patients, the visual scores of all categories were significantly lower (P < .05) for clinical cine compared with real-time cine with GRASP + VS + KWIC, except for noise (P = .08). Conclusion Incorporating VS and KWIC filtering into GRASP reconstruction enables ultra-high temporal resolution (approximately 20 msec) without significant loss in spatial resolution. Keywords: Cine, View Sharing, k-Space-weighted Image Contrast Filtering, Radial k-Space, Pediatrics, Arrhythmia, GRASP, Compressed Sensing, Real-Time, Free-Breathing Supplemental material is available for this article. © RSNA, 2024.


  • Open Access

    GRASP reconstruction amplified with view‐sharing and KWIC filtering reduces underestimation of peak velocity in highly‐accelerated real‐time phase‐contrast MRI: A preliminary evaluation in pediatric patients with congenital heart disease

    by Huili Yang, KyungPyo Hong, Justin J. Baraboo, Lexiaozi Fan, Andrine Larsen, Michael Markl, Joshua D. Robinson, Cynthia K. Rigsby, Daniel Kim

    Purpose: To develop a highly‐accelerated, real‐time phase contrast (rtPC) MRI pulse sequence with 40 fps frame rate (25 ms effective temporal resolution).Methods: Highly‐accelerated golden‐angle radial sparse parallel (GRASP) with over regularization may result in temporal blurring, which in turn causes underestimation of peak velocity. Thus, we amplified GRASP performance by synergistically combining view‐sharing (VS) and k‐space weighted image contrast (KWIC) filtering. In 17 pediatric patients with congenital heart disease (CHD), the conventional GRASP and the proposed GRASP amplified by VS and KWIC (or GRASP + VS + KWIC) reconstruction for rtPC MRI were compared with respect to clinical standard PC MRI in measuring hemodynamic parameters (peak velocity, forward volume, backward volume, regurgitant fraction) at four locations (aortic valve, pulmonary valve, left and right pulmonary arteries).Results: The proposed reconstruction method (GRASP + VS + KWIC) achieved better effective spatial resolution (i.e., image sharpness) compared with conventional GRASP, ultimately reducing the underestimation of peak velocity from 17.4% to 6.4%. The hemodynamic metrics (peak velocity, volumes) were not significantly (p > 0.99) different between GRASP + VS + KWIC and clinical PC, whereas peak velocity was significantly (p < 0.007) lower for conventional GRASP. RtPC with GRASP + VS + KWIC also showed the ability to assess beat‐to‐beat variation and detect the highest peak among peaks.Conclusion: The synergistic combination of GRASP, VS, and KWIC achieves 25 ms effective temporal resolution (40 fps frame rate), while minimizing the underestimation of peak velocity compared with conventional GRASP.


  • Open Access

    Optimal saturation recovery time for minimizing the underestimation of arterial input function in quantitative cardiac perfusion MRI

    by Lexiaozi Fan, Kyungpyo Hong, Li‐Yueh Hsu, James C. Carr, Bradley D. Allen, Daniel C. Lee, Daniel Kim

    Purpose: The purpose of this study was to determine an optimal saturation‐recovery time (TS) for minimizing the underestimation of arterial input function (AIF) in quantitative cardiac perfusion MRI without multiple gadolinium injections per subject.Methods: We scanned 18 subjects (mean age = 59 ± 14 years, 9/9 males/females) to acquire resting perfusion data and 1 additional subject (age = 38 years, male) to obtain stress‐rest perfusion data using a 5‐fold accelerated pulse sequence with radial k‐space sampling and applied k‐space weighted image contrast (KWIC) filters on the same k‐space data to retrospectively reconstruct five AIF images with effective TS ranging from 10 to 21.2 ms (2.8 ms steps). Undersampled images were reconstructed using a compressed sensing framework with temporal‐total‐variation and temporal‐principal‐component as 2 orthogonal sparsifying transforms. The image processing steps included, same motion correction across five different AIF images, signal normalization by the proton‐density‐weighted‐image, signal‐to‐T1 conversion using a Bloch equation, T1‐to‐gadolinium‐concentration conversion assuming fast water exchange, T2* correction to the AIF, and gadolinium‐concentration to myocardial blood flow (MBF) conversion based on a Fermi model.Results: Among five TS values, the shortest TS (10 ms) produced significantly (P < 0.05) higher peak AIF and lower resting MBF (13.73 mM, 0.73 mL g−1 min−1) than 12.8 ms (11.24 mM, 0.89 mL g−1 min−1), 15.6 ms (9.56 mM, 1.05 mL g−1 min−1), 18.4 ms (8.55 mM, 1.17 mL g−1 min−1), and 21.2 ms (7.95 mM, 1.27 mL g−1 min−1). Similarly, shorter TS reduced underestimation of AIF (or overestimation of MBF) for both during stress and at rest, but this effect was canceled in myocardial‐perfusion‐reserve (MPR).Conclusion: This study demonstrates that TS of 10 ms reduces the underestimation of AIF and, hence, the overestimation of MBF compared with longer TS values (12.8‐21.2 ms).


  • A theoretical framework for retrospective correction to the arterial input function in quantitative myocardial perfusion MRI

    by Lexiaozi Fan, Bradley D. Allen, Austin E. Culver, Li‐Yueh Hsu, Kyungpyo Hong, Brandon C. Benefield, James C. Carr, Daniel C. Lee, Daniel Kim

    Purpose: To develop and evaluate a flexible, Bloch‐equation based framework for retrospective correction to the arterial input function (AIF) obtained with quantitative cardiac perfusion pulse sequences.Methods: Our framework initially calculates the gadolinium concentration [Gd] based on T1 measurements alone. Next, is estimated from this initial calculation of [Gd] while assuming fast water exchange and using the literature native T2 and static magnetic field variation (ΔB0) values. Finally, the [Gd] is recalculated after performing correction to the Bloch equation signal model. Using this approach, we performed correction to historical phantom and in vivo, dual‐imaging perfusion data sets from 3 different patient groups obtained using different pulse sequences and imaging parameters. Images were processed to quantify both the AIF and resting myocardial blood flow (MBF). We also performed a sensitivity analysis of our correction to ±20% variations in native T2 and ΔB0.Results: Compared with the ground truth [Gd] of phantom, the normalized root‐means‐square‐error (NRMSE) in measured [Gd] was 5.1%, 1.3%, and 0.6% for uncorrected, our corrected, and Kellman’s corrected, respectively. For in vivo data, both the peak AIF (7.0 ± 3.0 mM vs. 8.6 ± 7.1 mM, 7.2 ± 0.9 mM vs. 8.6 ± 1.7 mM, 7.7 ± 1.8 mM vs. 10.3 ± 5.1 mM, P < .001) and resting MBF (1.3 ± 0.1 mL/g/min vs. 1.1 ± 0.1 mL/g/min, 1.3 ± 0.1 mL/g/min vs. 1.1 ± 0.1 mL/g/min, 1.2 ± 0.1 mL/g/min vs. 0.9 ± 0.1 mL/g/min, P < .001) values were significantly different between uncorrected and corrected for all 3 patient groups. Both the peak AIF and resting MBF values varied by 2 and ΔB0.Conclusion: Our theoretical framework enables retrospective correction to the AIF obtained with dual‐imaging, cardiac perfusion pulse sequences.