Ultra-rapid, Free-breathing, Real-time Cardiac Cine MRI Using GRASP Amplified with View Sharing and KWIC Filtering
Authors:
- Lexiaozi FanLFLexiaozi Fan
- KyungPyo HongKHKyungPyo Hong
- Bradley D. AllenBABradley D. Allen
- Rupsa PaulRPRupsa Paul
- James C. CarrJCJames C. Carr
- Sarah ZhangSZSarah Zhang
- Rod PassmanRPRod Passman
- Joshua D. RobinsonJRJoshua D. Robinson
- Daniel C. LeeDLDaniel C. Lee
- Cynthia K. RigsbyCRCynthia K. Rigsby
- Daniel KimDKDaniel Kim
- 1 February 2024
- journal article
- research article
- Published by Radiological Society of North America (RSNA) in Radiology: Cardiothoracic Imaging
- Vol. 6 (1) , e230107
Abstract
Purpose To achieve ultra-high temporal resolution (approximately 20 msec) in free-breathing, real-time cardiac cine MRI using golden-angle radial sparse parallel (GRASP) reconstruction amplified with view sharing (VS) and k-space-weighted image contrast (KWIC) filtering. Materials and Methods Fourteen pediatric patients with congenital heart disease (mean age [SD], 9 years ± 2; 13 male) and 10 adult patients with arrhythmia (mean age, 62 years ± 8; nine male) who underwent both standard breath-hold cine and free-breathing real-time cine using GRASP were retrospectively identified. To achieve high temporal resolution, each time frame was reconstructed using six radial spokes, corresponding to acceleration factors ranging from 24 to 32. To compensate for loss in spatial resolution resulting from over-regularization in GRASP, VS and KWIC filtering were incorporated. The blur metric, visual image quality scores, and biventricular parameters were compared between clinical and real-time cine images. Results In pediatric patients, the incorporation of VS and KWIC into GRASP (ie, GRASP + VS + KWIC) produced significantly (P < .05) sharper x-y-t (blur metric: 0.36 ± 0.03, 0.41 ± 0.03, 0.48 ± 0.03, respectively) and x-y-f (blur metric: 0.28 ± 0.02, 0.31 ± 0.03, 0.37 ± 0.03, respectively) component images compared with GRASP + VS and conventional GRASP. Only the noise score differed significantly between GRASP + VS + KWIC and clinical cine; all visual scores were above the clinically acceptable (3.0) cutoff point. Biventricular volumetric parameters strongly correlated (R2 > 0.85) between clinical and real-time cine images reconstructed with GRASP + VS + KWIC and were in good agreement (relative error < 6% for all parameters). In adult patients, the visual scores of all categories were significantly lower (P < .05) for clinical cine compared with real-time cine with GRASP + VS + KWIC, except for noise (P = .08). Conclusion Incorporating VS and KWIC filtering into GRASP reconstruction enables ultra-high temporal resolution (approximately 20 msec) without significant loss in spatial resolution. Keywords: Cine, View Sharing, k-Space-weighted Image Contrast Filtering, Radial k-Space, Pediatrics, Arrhythmia, GRASP, Compressed Sensing, Real-Time, Free-Breathing Supplemental material is available for this article. © RSNA, 2024.Keywords
Funding Information
- National Institutes of Health (R01HL116895, R21AG055954, R01HL151079, R21EB030806A1, 1R01HL167148-01A1)
- American Heart Association (9IPLOI34760317, 949899, 903375)
- Radiological Society of North America (EILTC2302)
This publication has 24 references indexed in Scilit:
- Response to Letter to the Editor: “Nomenclature for real‐time magnetic resonance imaging”Magnetic Resonance in Medicine, 2019
- Validation of highly accelerated real‐time cardiac cine MRI with radial k‐space sampling and compressed sensing in patients at 1.5T and 3TMagnetic Resonance in Medicine, 2017
- 3D Cartesian MRI with compressed sensing and variable view sharing using complementary poisson‐disc samplingMagnetic Resonance in Medicine, 2016
- Golden‐angle radial sparse parallel MRI: Combination of compressed sensing, parallel imaging, and golden‐angle radial sampling for fast and flexible dynamic volumetric MRIMagnetic Resonance in Medicine, 2013
- Highly accelerated real‐time cardiac cine MRI using k–t SPARSE‐SENSEMagnetic Resonance in Medicine, 2012
- Real‐time MRI at a resolution of 20 msNMR in Biomedicine, 2010
- Magnetic resonance imaging in real time: Advances using radial FLASHJournal of Magnetic Resonance Imaging, 2009
- Time‐resolved contrast‐enhanced imaging with isotropic resolution and broad coverage using an undersampled 3D projection trajectoryMagnetic Resonance in Medicine, 2002
- k-Space weighted image contrast (KWIC) for contrast manipulation in projection reconstruction MRIMagnetic Resonance in Medicine, 2000
- “Keyhole” method for accelerating imaging of contrast agent uptakeJournal of Magnetic Resonance Imaging, 1993