Somenath Banerjee
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Somenath Banerjee has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Santanu Kumar Mishra
Indian Institute of Technology Delhi, Delhi, India
4 shared publications Anil Suresh
American Energy Storage Innovations, Bangalore, India
1 shared publicationBhanu Teja Vankayalapati
1 shared publication- Debjit Rana
IIT Delhi, New Delhi, India
1 shared publication - Rajeev Kumar Singh
Department of Electrical Engineering, Indian Institute of Technology (BHU) Varanasi, Varanasi, India
1 shared publication Santanu K. Mishra
Centre for Automotive Research and Tribology, Indian Institute of Technology, New Delhi, India
1 shared publication
Latest Publications
- 12 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 14 (2) , 2394-2403
An Iterative Current Harmonic Suppression Algorithm for Single-Phase Distorted Grid Applications
The distorted grid voltage in the distribution system induces lower order harmonics in the current sourced from the Single-phase Grid-connected Inverter (SGI). Non-idealities of the SGI also contribute to the current distortion. This paper presents a novel iterative algorithm for the SGI which suppresses current harmonics due to both the grid-side and inverter-side distortions. The mathematical basis of the method is derived in this paper. The iterative algorithm is developed ensuring a computationally light implementation in modern digital microcontrollers. The proposed algorithm is verified in simulation under practical grid conditions like in a Low Voltage Distribution System (LVDS). Further experimental verifications were performed on a 1.1 kW laboratory prototype of an SGI with inverter-side distortion connected to distorted grid. Different lower order harmonics were separately suppressed under predefined thresholds. The measured total harmonic distortion in the current was improved from 22.24 % to 2.73 % at rated power.
- 12 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 14 (2) , 2394-2403
An Iterative Current Harmonic Suppression Algorithm for Single-Phase Distorted Grid Applications
The distorted grid voltage in the distribution system induces lower order harmonics in the current sourced from the Single-phase Grid-connected Inverter (SGI). Non-idealities of the SGI also contribute to the current distortion. This paper presents a novel iterative algorithm for the SGI which suppresses current harmonics due to both the grid-side and inverter-side distortions. The mathematical basis of the method is derived in this paper. The iterative algorithm is developed ensuring a computationally light implementation in modern digital microcontrollers. The proposed algorithm is verified in simulation under practical grid conditions like in a Low Voltage Distribution System (LVDS). Further experimental verifications were performed on a 1.1 kW laboratory prototype of an SGI with inverter-side distortion connected to distorted grid. Different lower order harmonics were separately suppressed under predefined thresholds. The measured total harmonic distortion in the current was improved from 22.24 % to 2.73 % at rated power.
- 14 October 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 62 (3) , 4100-4109
Impact of Quadrature Signal Generator Performance on the Power Quality of Single-Phase Grid-Connected Inverter
The grid voltage harmonics in the distribution system induces lower order harmonic currents in the output of Single-phase Grid-connected Inverter (SGI). Non-idealities of the SGI also contribute to the grid current distortion. The distortion in the SGI output current is directly dependent on the output impedance offered by the SGI at harmonic frequencies. The Quadrature Signal Generator (QSG) used for the grid current is an important building block in the SRF-based control scheme of the SGI. In this paper, the performance of the current QSG (iQSG) is linked to the power quality of the SGI and a generalized analytical approach to calculate the equivalent impedance of the SGI at harmonic frequencies is derived. The developed impedance model is used to quantitatively compare four widely used QSG techniques on the basis of power quality and other performance metrics pertaining to an iQSG. The analysis is validated in simulation under distorted grid conditions similar to a Low Voltage Distribution System (LVDS). Further experimental verifications were performed on a 700 W laboratory prototype of a Current-Fed Switched Inverter (CFSI) connected to a 230 V distorted grid. The theoretically calculated and experimentally measured output impedances of the SGI at harmonic frequencies are shown to closely follow each other.
- 14 October 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 62 (3) , 4100-4109
Impact of Quadrature Signal Generator Performance on the Power Quality of Single-Phase Grid-Connected Inverter
The grid voltage harmonics in the distribution system induces lower order harmonic currents in the output of Single-phase Grid-connected Inverter (SGI). Non-idealities of the SGI also contribute to the grid current distortion. The distortion in the SGI output current is directly dependent on the output impedance offered by the SGI at harmonic frequencies. The Quadrature Signal Generator (QSG) used for the grid current is an important building block in the SRF-based control scheme of the SGI. In this paper, the performance of the current QSG (iQSG) is linked to the power quality of the SGI and a generalized analytical approach to calculate the equivalent impedance of the SGI at harmonic frequencies is derived. The developed impedance model is used to quantitatively compare four widely used QSG techniques on the basis of power quality and other performance metrics pertaining to an iQSG. The analysis is validated in simulation under distorted grid conditions similar to a Low Voltage Distribution System (LVDS). Further experimental verifications were performed on a 700 W laboratory prototype of a Current-Fed Switched Inverter (CFSI) connected to a 230 V distorted grid. The theoretically calculated and experimentally measured output impedances of the SGI at harmonic frequencies are shown to closely follow each other.
- 22 August 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Industrial Electronics
- Vol. 6 (4) , 1491-1502
An Averaged Discrete Circuit Model for a Single-Phase Grid-Connected Inverter
Simulation of low voltage distribution grid with many Single-phase Grid-connected Inverters (SGIs) is an important requirement for researchers and system planners. The paper presents an Averaged Discrete Circuit Model (ADCM) of the power stage an SGI. This proposed model achieves excellent accuracy at a fraction of the execution time compared to RealTime Switching (RTS) simulation model. The derivation of the discrete-time model for the SGI from the fundamental inverter equations is presented. The model is verified and compared with existing models for various practical scenarios such as grid-feeding inverter, active power filter, short circuit fault. A 27-bus radial LV distribution grid with 15 SGIs is used to verify the performance of the proposed model in a distribution network simulation. Time taken for simulation by the proposed model is orders of magnitude less compared to a RTS model with less than 0.1 % difference in accuracy compared to a conventional Voltage Controlled Voltage Source (VCVS) model.
- 22 August 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Industrial Electronics
- Vol. 6 (4) , 1491-1502
An Averaged Discrete Circuit Model for a Single-Phase Grid-Connected Inverter
Simulation of low voltage distribution grid with many Single-phase Grid-connected Inverters (SGIs) is an important requirement for researchers and system planners. The paper presents an Averaged Discrete Circuit Model (ADCM) of the power stage an SGI. This proposed model achieves excellent accuracy at a fraction of the execution time compared to RealTime Switching (RTS) simulation model. The derivation of the discrete-time model for the SGI from the fundamental inverter equations is presented. The model is verified and compared with existing models for various practical scenarios such as grid-feeding inverter, active power filter, short circuit fault. A 27-bus radial LV distribution grid with 15 SGIs is used to verify the performance of the proposed model in a distribution network simulation. Time taken for simulation by the proposed model is orders of magnitude less compared to a RTS model with less than 0.1 % difference in accuracy compared to a conventional Voltage Controlled Voltage Source (VCVS) model.
- 28 April 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 40 (9) , 12614-12625
A Modified Asymmetric Half-Bridge Topology for High-Voltage High-Power Intermediate Bus Converters
The article presents a converter topology designed for high-voltage, and high-power applications. The proposed topology uses two switches each in the primary and secondary. Existing solutions suitable for these applications face limitations in terms of the transformer dc flux at high power levels, which leads to larger core size. This article proposes a methodology to design the transformer at high power and high buck ratio to minimize dc flux problem. In doing so, zero voltage switching (ZVS) operation is forced to be comparable to the existing solutions by selecting a suitable ZVS inductor. The proposed converter achieves an 80% reduction in dc flux from the existing topology at rated power. Analysis of the operating intervals of the proposed converter and its dynamic modeling are presented. Based on these analyses, a 1600 V to 24 V/ 1.4 kW voltage regulated prototype is designed and its operation is validated.
- 28 April 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 40 (9) , 12614-12625
A Modified Asymmetric Half-Bridge Topology for High-Voltage High-Power Intermediate Bus Converters
The article presents a converter topology designed for high-voltage, and high-power applications. The proposed topology uses two switches each in the primary and secondary. Existing solutions suitable for these applications face limitations in terms of the transformer dc flux at high power levels, which leads to larger core size. This article proposes a methodology to design the transformer at high power and high buck ratio to minimize dc flux problem. In doing so, zero voltage switching (ZVS) operation is forced to be comparable to the existing solutions by selecting a suitable ZVS inductor. The proposed converter achieves an 80% reduction in dc flux from the existing topology at rated power. Analysis of the operating intervals of the proposed converter and its dynamic modeling are presented. Based on these analyses, a 1600 V to 24 V/ 1.4 kW voltage regulated prototype is designed and its operation is validated.
- 22 May 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 2188-2193
An Average Circuit Model of a Single-phase Grid-connected Inverter
The use of numerous Single-phase Grid-connected Inverters (SGI) is becoming a reality due to the implementation of smart LV-distribution grid. Power system planners generally use circuit simulation software to test and validate any planned expansion of the grid system. This simulation becomes resource and time consuming when many high switching frequency SGIs are present. To provide them with a simple yet accurate model of SGI, this paper proposes a loss-free impedance-based average circuit model. The development of the model and its experimental and simulation validations are covered in this work. The average circuit model is about 14 times faster than the switching circuit in the simulation test case and maximum error is 1.3 % in steady state.
- 22 May 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 2188-2193
An Average Circuit Model of a Single-phase Grid-connected Inverter
The use of numerous Single-phase Grid-connected Inverters (SGI) is becoming a reality due to the implementation of smart LV-distribution grid. Power system planners generally use circuit simulation software to test and validate any planned expansion of the grid system. This simulation becomes resource and time consuming when many high switching frequency SGIs are present. To provide them with a simple yet accurate model of SGI, this paper proposes a loss-free impedance-based average circuit model. The development of the model and its experimental and simulation validations are covered in this work. The average circuit model is about 14 times faster than the switching circuit in the simulation test case and maximum error is 1.3 % in steady state.
- 11 February 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Vehicular Technology
- Vol. 69 (4) , 3760-3772
A Reconfigurable On-Board Power Converter for Electric Vehicle With Reduced Switch Count
- 11 February 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Vehicular Technology
- Vol. 69 (4) , 3760-3772
A Reconfigurable On-Board Power Converter for Electric Vehicle With Reduced Switch Count