Sebastian Marschner
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Sebastian Marschner has a total of 261 co-authors. Here are the top co-authors by number of shared publications:
Claus Belka
16 shared publications- Stefanie Corradini
Department of Radiation Oncology, Uniklinikum Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg
9 shared publications - Claus Belka
Department of Radiation Oncology, University Hospital LMU, Marchioninistrasse 15, Munich, 81377, Germany, 49 89440073770
7 shared publications Maximilian Niyazi
7 shared publicationsStefanie Corradini
6 shared publicationsChristopher Kurz
Department of Radiation Oncology, LMU University Hospital, Munich, Germany
5 shared publications
Latest Publications
- Open Access
- 14 November 2026
- Published by Elsevier in Zeitschrift für Medizinische Physik
Impact of ROI definition on head and neck cancer FDG-PET radiomics
- 14 November 2026
- Published by Elsevier in Zeitschrift für Medizinische Physik
Open AccessImpact of ROI definition on head and neck cancer FDG-PET radiomics
- Open Access
- 26 May 2026
- Published by Elsevier in Clinical and Translational Radiation Oncology
- Vol. 59, 101198
Postoperative fractionated stereotactic radiotherapy for completely resected brain metastases with 25 Gy in five fractions: A single-center retrospective study
- 26 May 2026
- Published by Elsevier in Clinical and Translational Radiation Oncology
- Vol. 59, 101198
Open AccessPostoperative fractionated stereotactic radiotherapy for completely resected brain metastases with 25 Gy in five fractions: A single-center retrospective study
- 10 January 2026
- Published by Elsevier in Radiotherapy and Oncology
- Vol. 216, 111377
AI-based assessment of brain volume decrease after treatment with stereotactic radiosurgery versus whole brain radiotherapy
- 10 January 2026
- Published by Elsevier in Radiotherapy and Oncology
- Vol. 216, 111377
AI-based assessment of brain volume decrease after treatment with stereotactic radiosurgery versus whole brain radiotherapy
- Open Access
- 20 November 2025
- Published by Elsevier in Technical Innovations & Patient Support in Radiation Oncology
- Vol. 36
Improved PTV coverage and OAR sparing with stereotactic MRI-guided online adaptive radiotherapy with elective fields in pancreatic cancer
- 20 November 2025
- Published by Elsevier in Technical Innovations & Patient Support in Radiation Oncology
- Vol. 36
Open AccessImproved PTV coverage and OAR sparing with stereotactic MRI-guided online adaptive radiotherapy with elective fields in pancreatic cancer
- Open Access
- 28 October 2025
- Published by Elsevier in Radiotherapy and Oncology
- Vol. 214, 111237
Multicenter analysis of MRI-guided, stereotactic body radiotherapy as ablative treatment for lymph nodal metastases of the abdomen and pelvis
- 28 October 2025
- Published by Elsevier in Radiotherapy and Oncology
- Vol. 214, 111237
Open AccessMulticenter analysis of MRI-guided, stereotactic body radiotherapy as ablative treatment for lymph nodal metastases of the abdomen and pelvis
- Open Access
- 15 July 2025
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 70 (14) , 145018
Deep learning-based contour propagation in magnetic resonance imaging-guided radiotherapy of lung cancer patients
Objective. Fast and accurate organ-at-risk (OAR) and gross tumor volume (GTV) contour propagation methods are needed to improve the efficiency of magnetic resonance (MR) imaging-guided radiotherapy. We trained deformable image registration networks to accurately propagate contours from planning to fraction MR images. Approach. Data from 140 stage 1–2 lung cancer patients treated at a 0.35 T MR-Linac were split into 102/17/21 for training/validation/testing. Additionally, 18 central lung tumor patients, treated at a 0.35 T MR-Linac externally, and 14 stage 3 lung cancer patients from a phase 1 clinical trial, treated at 0.35 T or 1.5 T MR-Linacs at three institutions, were used for external testing. Planning and fraction images were paired (490 pairs) for training. Two hybrid transformer-convolutional neural network TransMorph models with mean squared error (MSE), Dice similarity coefficient (DSC), and regularization losses (TMMSE+Dice) or MSE and regularization losses (TMMSE) were trained to deformably register planning to fraction images. The TransMorph models predicted diffeomorphic dense displacement fields. Multi-label images including seven thoracic OARs and the GTV were propagated to generate fraction segmentations. Model predictions were compared with contours obtained through B-spline, vendor registration and the auto-segmentation method nnUNet. Evaluation metrics included the DSC and Hausdorff distance percentiles (50th and 95th) against clinical contours. Main results. TMMSE+Dice and TMMSE achieved mean OARs/GTV DSCs of 0.90/0.82 and 0.90/0.79 for the internal and 0.84/0.77 and 0.85/0.76 for the central lung tumor external test data. On stage 3 data, TMMSE+Dice achieved mean OARs/GTV DSCs of 0.87/0.79 and 0.83/0.78 for the 0.35 T MR-Linac datasets, and 0.87/0.75 for the 1.5 T MR-Linac dataset. TMMSE+Dice and TMMSE had significantly higher geometric accuracy than other methods on external data. No significant difference between TMMSE+Dice and TMMSE was found. Significance. TransMorph models achieved time-efficient segmentation of fraction MRIs with high geometrical accuracy and accurately segmented images obtained at different field strengths.
- 15 July 2025
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 70 (14) , 145018
Open AccessDeep learning-based contour propagation in magnetic resonance imaging-guided radiotherapy of lung cancer patients
Objective. Fast and accurate organ-at-risk (OAR) and gross tumor volume (GTV) contour propagation methods are needed to improve the efficiency of magnetic resonance (MR) imaging-guided radiotherapy. We trained deformable image registration networks to accurately propagate contours from planning to fraction MR images. Approach. Data from 140 stage 1–2 lung cancer patients treated at a 0.35 T MR-Linac were split into 102/17/21 for training/validation/testing. Additionally, 18 central lung tumor patients, treated at a 0.35 T MR-Linac externally, and 14 stage 3 lung cancer patients from a phase 1 clinical trial, treated at 0.35 T or 1.5 T MR-Linacs at three institutions, were used for external testing. Planning and fraction images were paired (490 pairs) for training. Two hybrid transformer-convolutional neural network TransMorph models with mean squared error (MSE), Dice similarity coefficient (DSC), and regularization losses (TMMSE+Dice) or MSE and regularization losses (TMMSE) were trained to deformably register planning to fraction images. The TransMorph models predicted diffeomorphic dense displacement fields. Multi-label images including seven thoracic OARs and the GTV were propagated to generate fraction segmentations. Model predictions were compared with contours obtained through B-spline, vendor registration and the auto-segmentation method nnUNet. Evaluation metrics included the DSC and Hausdorff distance percentiles (50th and 95th) against clinical contours. Main results. TMMSE+Dice and TMMSE achieved mean OARs/GTV DSCs of 0.90/0.82 and 0.90/0.79 for the internal and 0.84/0.77 and 0.85/0.76 for the central lung tumor external test data. On stage 3 data, TMMSE+Dice achieved mean OARs/GTV DSCs of 0.87/0.79 and 0.83/0.78 for the 0.35 T MR-Linac datasets, and 0.87/0.75 for the 1.5 T MR-Linac dataset. TMMSE+Dice and TMMSE had significantly higher geometric accuracy than other methods on external data. No significant difference between TMMSE+Dice and TMMSE was found. Significance. TransMorph models achieved time-efficient segmentation of fraction MRIs with high geometrical accuracy and accurately segmented images obtained at different field strengths.
- Open Access
- 16 May 2025
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 70 (10) , 105018
Patient-specific uncertainty calibration of deep learning-based autosegmentation networks for adaptive MRI-guided lung radiotherapy
Objective. Uncertainty assessment of deep learning autosegmentation (DLAS) models can support contour corrections in adaptive radiotherapy (ART), e.g. by utilizing Monte Carlo Dropout (MCD) uncertainty maps. However, poorly calibrated uncertainties at the patient level often render these clinically nonviable. We evaluated population-based and patient-specific DLAS accuracy and uncertainty calibration and propose a patient-specific post-training uncertainty calibration method for DLAS in ART. Approach. The study included 122 lung cancer patients treated with a low-field MR-linac (80/19/23 training/validation/test cases). Ten single-label 3D-U-Net population-based baseline models (BM) were trained with dropout using planning MRIs (pMRIs) and contours for nine organs-at-riks (OARs) and gross tumor volumes (GTVs). Patient-specific models (PS) were created by fine-tuning BMs with each test patient’s pMRI. Model uncertainty was assessed with MCD, averaged into probability maps. Uncertainty calibration was evaluated with reliability diagrams and expected calibration error (ECE). A proposed post-training calibration method rescaled MCD probabilities for fraction images in BM (calBM) and PS (calPS) after fitting reliability diagrams from pMRIs. All models were evaluated on fraction images using Dice similarity coefficient (DSC), 95th percentile Hausdorff distance (HD95) and ECE. Metrics were compared among models for all OARs combined (n = 163), and the GTV (n = 23), using Friedman and posthoc-Nemenyi tests (α = 0.05). Main results. For the OARs, patient-specific fine-tuning significantly (p < 0.001) increased median DSC from 0.78 (BM) to 0.86 (PS) and reduced HD95 from 14 mm (BM) to 6.0 mm (PS). Uncertainty calibration achieved substantial reductions in ECE, from 0.25 (BM) to 0.091 (calBM) and 0.22 (PS) to 0.11 (calPS) (p < 0.001), without significantly affecting DSC or HD95 (p > 0.05). For the GTV, BM performance was poor (DSC = 0.05) but significantly (p < 0.001) improved with PS training (DSC = 0.75) while uncertainty calibration reduced ECE from 0.22 (PS) to 0.15 (calPS) (p = 0.45). Significance. Post-training uncertainty calibration yields geometrically accurate DLAS models with well-calibrated uncertainty estimates, crucial for ART applications.
- 16 May 2025
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 70 (10) , 105018
Open AccessPatient-specific uncertainty calibration of deep learning-based autosegmentation networks for adaptive MRI-guided lung radiotherapy
Objective. Uncertainty assessment of deep learning autosegmentation (DLAS) models can support contour corrections in adaptive radiotherapy (ART), e.g. by utilizing Monte Carlo Dropout (MCD) uncertainty maps. However, poorly calibrated uncertainties at the patient level often render these clinically nonviable. We evaluated population-based and patient-specific DLAS accuracy and uncertainty calibration and propose a patient-specific post-training uncertainty calibration method for DLAS in ART. Approach. The study included 122 lung cancer patients treated with a low-field MR-linac (80/19/23 training/validation/test cases). Ten single-label 3D-U-Net population-based baseline models (BM) were trained with dropout using planning MRIs (pMRIs) and contours for nine organs-at-riks (OARs) and gross tumor volumes (GTVs). Patient-specific models (PS) were created by fine-tuning BMs with each test patient’s pMRI. Model uncertainty was assessed with MCD, averaged into probability maps. Uncertainty calibration was evaluated with reliability diagrams and expected calibration error (ECE). A proposed post-training calibration method rescaled MCD probabilities for fraction images in BM (calBM) and PS (calPS) after fitting reliability diagrams from pMRIs. All models were evaluated on fraction images using Dice similarity coefficient (DSC), 95th percentile Hausdorff distance (HD95) and ECE. Metrics were compared among models for all OARs combined (n = 163), and the GTV (n = 23), using Friedman and posthoc-Nemenyi tests (α = 0.05). Main results. For the OARs, patient-specific fine-tuning significantly (p < 0.001) increased median DSC from 0.78 (BM) to 0.86 (PS) and reduced HD95 from 14 mm (BM) to 6.0 mm (PS). Uncertainty calibration achieved substantial reductions in ECE, from 0.25 (BM) to 0.091 (calBM) and 0.22 (PS) to 0.11 (calPS) (p < 0.001), without significantly affecting DSC or HD95 (p > 0.05). For the GTV, BM performance was poor (DSC = 0.05) but significantly (p < 0.001) improved with PS training (DSC = 0.75) while uncertainty calibration reduced ECE from 0.22 (PS) to 0.15 (calPS) (p = 0.45). Significance. Post-training uncertainty calibration yields geometrically accurate DLAS models with well-calibrated uncertainty estimates, crucial for ART applications.
- Open Access
- 24 December 2024
- Published by Elsevier in Radiotherapy and Oncology
- Vol. 204, 110697
Predicting cisplatin tolerability in older adults with head and neck cancer – Insights for improved chemoradiation outcomes
- 24 December 2024
- Published by Elsevier in Radiotherapy and Oncology
- Vol. 204, 110697
Open AccessPredicting cisplatin tolerability in older adults with head and neck cancer – Insights for improved chemoradiation outcomes
- Open Access
- 14 October 2024
- Published by Springer Nature in npj Digital Medicine
- Vol. 7 (1) , 1-12
Privacy-friendly evaluation of patient data with secure multiparty computation in a European pilot study
In multicentric studies, data sharing between institutions might negatively impact patient privacy or data security. An alternative is federated analysis by secure multiparty computation. This pilot study demonstrates an architecture and implementation addressing both technical challenges and legal difficulties in the particularly demanding setting of clinical research on cancer patients within the strict European regulation on patient privacy and data protection: 24 patients from LMU University Hospital in Munich, Germany, and 24 patients from Policlinico Universitario Fondazione Agostino Gemelli, Rome, Italy, were treated for adrenal gland metastasis with typically 40 Gy in 3 or 5 fractions of online-adaptive radiotherapy guided by real-time MR. High local control (21% complete remission, 27% partial remission, 40% stable disease) and low toxicity (73% reporting no toxicity) were observed. Median overall survival was 19 months. Federated analysis was found to improve clinical science through privacy-friendly evaluation of patient data in the European health data space.
- 14 October 2024
- Published by Springer Nature in npj Digital Medicine
- Vol. 7 (1) , 1-12
Open AccessPrivacy-friendly evaluation of patient data with secure multiparty computation in a European pilot study
In multicentric studies, data sharing between institutions might negatively impact patient privacy or data security. An alternative is federated analysis by secure multiparty computation. This pilot study demonstrates an architecture and implementation addressing both technical challenges and legal difficulties in the particularly demanding setting of clinical research on cancer patients within the strict European regulation on patient privacy and data protection: 24 patients from LMU University Hospital in Munich, Germany, and 24 patients from Policlinico Universitario Fondazione Agostino Gemelli, Rome, Italy, were treated for adrenal gland metastasis with typically 40 Gy in 3 or 5 fractions of online-adaptive radiotherapy guided by real-time MR. High local control (21% complete remission, 27% partial remission, 40% stable disease) and low toxicity (73% reporting no toxicity) were observed. Median overall survival was 19 months. Federated analysis was found to improve clinical science through privacy-friendly evaluation of patient data in the European health data space.