YKYuichi Kuroda

Yuichi Kuroda

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Yuichi Kuroda has a total of 92 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Higher preoperative Advanced Activities Score of the 2011 Knee Society Score is associated with greater patient satisfaction after ground kinematically aligned total knee arthroplasty

    by Takuma Hayashi, Tomoyuki Matsumoto, Kemmei Ikuta, Masanori Tsubosaka, Tomoyuki Kamenaga, Yuichi Kuroda, Naoki Nakano, Kazunari Ishida, Shinya Hayashi, Ryosuke Kuroda

    Purpose: Ground kinematically aligned total knee arthroplasty, which uses the ground mechanical axis as a reference, has shown favourable clinical outcomes. Nevertheless, preoperative factors associated with post‐operative satisfaction remain unclear. This study aimed to identify preoperative predictors of patient satisfaction after ground kinematically aligned total knee arthroplasty using patient‐reported outcome measures. Methods: A total of 117 consecutive patients with varus knee osteoarthritis who underwent primary ground kinematically aligned total knee arthroplasty were retrospectively analyzed. Patients were classified into excellent satisfaction (≥32 points) and suboptimal satisfaction (B = 0.057). Receiver operating characteristic analysis identified an optimal cut‐off value of 12 (sensitivity = 0.744; specificity = 0.677). Multivariable logistic regression confirmed that higher preoperative Advanced Activities Score was independently associated with excellent post‐operative satisfaction (odds ratio = 1.320; p < 0.001). Conclusions: Higher preoperative activity level was associated with greater post‐operative satisfaction after ground kinematically aligned total knee arthroplasty. Level of Evidence: Level III.

  • Open Access

    VELYS robotic-assisted solution achieves more accurate bone cutting and neutral ground mechanical axis compared with an accelerometer-based portable navigation system in ground kinematically aligned total knee arthroplasty

    by Tomoyuki Matsumoto, Masanori Tsubosaka, Naoki Nakano, Tomoyuki Kamenaga, Yuichi Kuroda, Shinya Hayashi, Ryosuke Kuroda

    Purpose: This study aimed to compare the accuracy of bone cutting, achievement of target alignment, and early clinical outcomes between ground kinematically aligned total knee arthroplasty (KA-TKA) performed using the VELYS TM robotic-assisted solution (VRAS) and that performed using an accelerometer-based portable navigation system (APNS) in patients with varus osteoarthritis. Methods: This cohort study prospectively enrolled 35 consecutive patients who underwent ground KA-TKA using the VRAS and compared them with 35 consecutive patients treated with the same surgical procedure using the APNS. The primary end point was the accuracy of bone cutting and achievement of target alignment. Clinical outcomes were evaluated at 1 year postoperatively. Results: The VRAS group demonstrated significantly smaller mean absolute errors from target values, particularly in femoral bone cutting and achievement of a neutral ground mechanical axis, compared with the APNS group (0.7 ± 0.8° versus 1.5 ± 1.1°, 1.6 ± 1.8% versus 3.0 ± 2.4%, p < 0.05, respectively). There were no significant differences in range of motion and 2011 Knee Society Score between groups. Conclusions: Ground KA-TKA performed using the VRAS achieved higher accuracy in bone cutting and more reliable achievement of a neutral ground mechanical axis, compared with the APNS.

  • Comparison of the accuracy for cup positioning between portable inertial navigation systems and manual methods during total hip arthroplasty in the anterolateral supine position

    by Yuichi Kuroda, Tomoyuki Kamenaga, Naoki Nakano, Masanori Tsubosaka, Tomoyuki Matsumoto, Ryosuke Kuroda, Shinya Hayashi

    This study primarily aimed to compare the accuracy of acetabular cup positioning between the portable inertial navigation system (INS) Navbit Sprint and the manual method during total hip arthroplasty (THA) using the same cup in the supine position. The second aim was to investigate patient factors associated with cup positioning accuracy for THA with a portable INS. This study included 105 consecutive patients who underwent THA using a portable INS (n = 54) or manual methods (n = 51). The absolute difference between the target and postoperative angles, as determined by postoperative computed tomography data (placement error), was compared between the portable INS and manual method groups. The absolute value of the difference between the navigation and postoperative angles (measurement error) was also evaluated, and related factors were analyzed using multiple regression analysis. The average placement error with the portable INS group was 3.6 ± 2.7° and 2.6 ± 2.5° for inclination and anteversion, respectively. For the manual method group, the absolute difference was 6.0 ± 4.0° and 4.5 ± 3.5° for inclination and anteversion, respectively. Significant differences were observed between groups. The average measurement error of the portable INS group was 2.5 ± 1.9° and 2.7 ± 2.2° for inclination and anteversion, respectively. The measurement error for inclination significantly correlated with the leg length discrepancy. Cup positioning with the Navbit Sprint was significantly more accurate than the manual method during THA using the same cup in the anterolateral supine position. However, a significant leg length discrepancy could negatively impact the accuracy of cup positioning inclination.

  • Open Access

    Total Knee Arthroplasty for Secondary Osteoarthritis in Patients With Multiple Hereditary Exostoses: A Case Series

    by Mitsuyuki Kenai, Naoki Nakano, Masanori Tsubosaka, Tomoyuki Kamenaga, Yuichi Kuroda, Shinya Hayashi, Ryosuke Kuroda, Tomoyuki Matsumoto

    BACKGROUND Multiple hereditary exostoses (MHE) is a rare genetic disorder characterized by multiple osteochondromas, often leading to joint deformity and early-onset osteoarthritis (OA). The knee is one of the most commonly affected joints, and progressive deformity and malalignment may eventually require surgical intervention. Total knee arthroplasty (TKA) in patients with MHE remains technically demanding because of distorted joint anatomy and soft tissue imbalance. Because of the rarity of this condition, published reports describing surgical strategies and clinical and radiographic outcomes of TKA in patients with MHE remain limited. CASE REPORT We report 4 cases of MHE treated with TKA for advanced OA. Preoperative evaluation demonstrated varus or valgus deformities and limited range of motion in all cases. In all cases, TKA was performed using the measured resection technique. Two cases required constrained prostheses due to soft tissue imbalance. In 1 patient with a history of femoral fracture fixation and an obstructed femoral canal, portable navigation was employed to facilitate accurate bone resection. All patients achieved pain relief, with improved hip-knee-ankle (HKA) angle and range of motion. The mean 2011 Knee Society objective score improved from 48 preoperatively to 94.5 at the final follow-up, and the mean 2011 Knee Society functional score improved from 36 to 54.5. CONCLUSIONS Our experience suggests that TKA can yield favorable short-term clinical and radiographic outcomes in patients with MHE. Despite the technical challenges associated with distorted anatomy and soft tissue imbalance, individualized preoperative planning and appropriate intraoperative decision-making - including the selective use of constrained implants and navigation systems - can contribute to successful surgical outcomes.

  • Open Access

    Association between herniation pit and intra-articular pathology in patients with symptomatic femoroacetabular impingement syndrome

    by Yuichi Kuroda, Tomoyuki Kamenaga, Masanori Tsubosaka, Naoki Nakano, Tomoyuki Matsumoto, Ryosuke Kuroda, Shinya Hayashi

  • Open Access

    Does hip bone morphology differ depending on the presence of cam lesions in borderline developmental dysplasia of the hip?

    by Yuichi Kuroda, Tomoyuki Kamenaga, Shotaro Araki, Masanori Tsubosaka, Naoki Nakano, Tomoyuki Matsumoto, Shinya Hayashi, Ryosuke Kuroda

  • Open Access

    Amount of mechanical hip-knee-ankle (mHKA) angle correction by fixed-bearing medial UKA can be predicted using a new morphological assessment method: the arithmetic hip-knee-ankle (aHKA) angle

    by Naoki Nakano, Masanori Tsubosaka, Tomoyuki Kamenaga, Yuichi Kuroda, Kazunari Ishida, Shinya Hayashi, Ryosuke Kuroda, Tomoyuki Matsumoto

    Introduction: The amount of change in coronal alignment by unicompartmental knee arthroplasty (UKA) is important when considering its long-term results. This study investigated whether the amount of change in mechanical hip-knee-ankle (mHKA) angle by medial fixed-bearing UKA can be predicted based on the arithmetic hip-knee-ankle (aHKA) angle, an indicator of bony nature that is independent of soft tissue balance. Materials and methods: The research involved 101 patients (125 knees) who underwent medial fixed-bearing UKA with the spacer-block technique. Pre- and postoperative mHKA angles, aHKA angle (180°– lateral distal femoral angle + medial proximal tibial angle), insert thickness, and the amount of bone cuts were measured. The component gap in extension was measured using a UKA tensor, and the pre-osteotomy gap was calculated. The correlation between aHKA angle minus preoperative mHKA angle and changes in mHKA angle, as well as the pre-osteotomy gap, were analysed. Additionally, changes in mHKA angle and total osteotomy volume were compared based on insert thickness. Results: A positive correlation was found between aHKA angle minus preoperative mHKA angle and the change in mHKA angle. The pre-osteotomy gap was also positively correlated with aHKA angle minus preoperative HKA angle. Greater changes in mHKA angle occurred in cases with inserts ≥ 9 mm compared to 8 mm inserts, though osteotomy volume did not significantly differ between the groups. Conclusions: In fixed-bearing UKA, postoperative changes in mHKA angle are likely to be more pronounced when there is a significant difference between aHKA angle and preoperative mHKA angle. Surgical planning should account for this factor to optimise outcomes.


  • Valgus positioning of the femoral component does not compromise short-term clinical outcomes in fixed-bearing unicompartmental knee arthroplasty

    by Kensuke Anjiki, Naoki Nakano, Seiji Kubo, Kazunari Ishida, Kemmei Ikuta, Masanori Tsubosaka, Tomoyuki Kamenaga, Yuichi Kuroda, Shinya Hayashi, Ryosuke Kuroda, et al.

    Purpose In unicompartmental knee arthroplasty (UKA), the tibial component tends to be placed in a mildly varus position because of the expected improvement in stress distribution and load transfer across the tibia. With the spacer block technique in UKA, if a tibial osteotomy is performed in the varus position, the femoral component is placed in the valgus position. Therefore, this study aimed to evaluate the impact of valgus positioning of the femoral component on the short-term postoperative clinical outcomes in fixed-bearing UKA using the spacer block technique. Methods We analyzed 77 knees of 70 patients who underwent fixed-bearing UKA using the spacer block technique for medial compartment osteoarthritis and spontaneous osteonecrosis of the knee. Patients were categorized based on femoral component alignment: the neutral group (–3° to + 3°, mean 0.5° ± 1.7° valgus) and the valgus group (> 3°, mean 5.7° ± 1.7° valgus). Postoperative outcomes, including the femorotibial angle (FTA), component sagittal alignment, knee range of motion, and 2011 Knee Society Score (KSS), were compared between the two groups. Results No significant differences were found between the neutral and valgus groups regarding the postoperative FTA, component sagittal alignment, knee range of motion (neutral vs. valgus group; extension,°: − 1.9 ± 2.9 vs. − 1.6 ± 2.9; flexion,°: 133.0 ± 6.9 vs. 131.3 ± 7.9), or 2011 KSS (objective knee indicators: 95.0 ± 8.9 vs. 96.8 ± 3.5; functional activities: 78.9 ± 15.3 vs. 78.2 ± 12.9). Conclusion These findings support the safety of valgus positioning in fixed-bearing UKA, offering flexibility in component placement without compromising short-term clinical outcomes.

  • Impact of femoral stem alignment on periprosthetic bone density in THA: a study of the Avenir Complete stem

    by Takuma Maeda, Yuichi Kuroda, Tomoyuki Kamenaga, Tomoyuki Matsumoto, Ryosuke Kuroda, Shinya Hayashi

    Introduction Thigh pain, aseptic loosening, and failure after total hip arthroplasty has been reported. Therefore, this study examines the impact of femoral stem alignment on periprosthetic bone mineral density (BMD) in THA using the Avenir Complete cementless stem, focusing on the role of precise stem alignment in maintaining proximal femoral BMD. Materials and Methods Consecutive patients who received the Avenir Complete stem via mini anterolateral approach in the supine position between March 2019 and March 2022 were included. Dual-energy X-ray absorptiometry was used to assess BMD changes, and computed tomography scans were used to evaluate stem alignment. Results BMD was maintained in the distal femur, but showed a slight decrease in the proximal femur. A negative correlation was observed among varus malalignment, anteversion errors, and changes in BMD in the proximal femur. Conclusions The findings underscore the importance of accurate stem positioning in THA, particularly in avoiding varus malalignment and anteversion errors, as misalignment can adversely affect proximal femoral BMD and potentially lead to early stem loosening. This study enhances the understanding of the influence of the Avenir Complete stem on postoperative BMD, highlighting the need for precise alignment to optimize outcomes.


  • The Effect of Prosthesis Type on Intraoperative Soft-Tissue Balance and Clinical Outcomes in Modified Kinematically Aligned Cruciate-Retaining Total Knee Arthroplasty

    by Tomoyuki Matsumoto, Naoki Nakano, Kazunari Ishida, Yoshinori Takashima, Toshihisa Maeda, Yuichi Kuroda, Shinya Hayashi, Tekehiko Matsushita, Takahiro Niikura, Hirotsugu Muratsu, et al.

    Introduction Kinematically aligned total knee arthroplasty (KA-TKA) has gained interest for achieving more favorable clinical outcomes than mechanically aligned TKA. One of the advantages of KA-TKA is reported to be an easy acquisition of intraoperative soft-tissue balance without excessive medial release for varus osteoarthritis. However, we hypothesized that the prosthesis type affects intraoperative soft-tissue balance even in the KA-TKA. The present study aimed to compare intraoperative soft-tissue balance and clinical outcomes of KA-TKAs using single-radius (SR) or multiradius (MR) prostheses. Materials and Methods Consecutive 70 cruciate-retaining modified KA-TKAs (31 SR and 39 MR) were performed in patients with varus-type osteoarthritis using a navigation system. Intraoperative soft-tissue balance including joint component gap and varus/valgus balance was measured with femoral component placement and patellofemoral joint reduction throughout the range of motion using offset-type tensor and compared between the two groups. Two years postoperatively, the range of motion and 2011 Knee Society Scores were compared between the two groups. Results and Conclusion Joint component gaps showed no significant differences between the two groups from 0 to 30 degrees of flexion. However, during 60 to 120 degrees of flexion, joint component gaps of SR group showed significantly larger values than those of MR group (p < 0.05). There were no significant differences in varus/valgus balance throughout the range of motion between the two groups. The postoperative clinical outcomes showed no significant differences between the two groups. Interpretation Despite no difference in clinical outcomes, joint component gap showed different patterns due to the prosthesis type in modified KA-TKAs.