Chao Wang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Chao Wang has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Jichao Han
Harbin University of Science and Technology
3 shared publications - Yang Wang
School of Electrical and Electronic Engineering, Harbin University of Science and Technology, Harbin 150080, China
3 shared publications Baojun Ge
1 shared publication- Baojun Ge
Harbin University of Science and Technology, Harbin, China
1 shared publication Dong Jiechen
Harbin University of Science and Technology, Harbin, China
1 shared publication- Kai Zhang
School of Electrical and Electronic Engineering, Harbin University of Science and Technology, Harbin 150080, China
1 shared publication
Latest Publications
- 24 February 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Energy Conversion
- Vol. 36 (4) , 2703-2713
Coupled Electromagnetic-Fluid-Thermal Analysis for End Zone With Electric Screen in Large Water-Hydrogen-Hydrogen Cooled Turbine Generator Under Different End Winding Extensions
Extension lengths of the stator and rotor end windings will obviously affect the electromagnetic field, fluid flow, and temperature of end components in the end zone of large water-hydrogen-hydrogen cooled turbine generator. In this paper, a 330 MW water-hydrogen-hydrogen cooled turbine generator is analyzed. Flow network of this turbine generator is established. The fluid velocity and the pressure (boundary conditions) are obtained at the different positions of this turbine generator after solving the equations of flow network. Three-dimensional transient electromagnetic field is calculated in the turbine generator end zone. The leakage magnetic field and the losses (heat source) of end components are determined in the turbine generator end zone under the different lengths of stator and rotor end winding extension. Based on these results, three-dimensional fluid-thermal coupled model is given in the end zone. The distribution of complex fluid velocity in the turbine generator end zone is determined. The temperature distribution of the stator end winding, clamp plate, electric screen, and finger plate is studied under the different lengths of stator and rotor end winding extension. The calculated temperature results agree well with the measured values.
- 24 February 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Energy Conversion
- Vol. 36 (4) , 2703-2713
Coupled Electromagnetic-Fluid-Thermal Analysis for End Zone With Electric Screen in Large Water-Hydrogen-Hydrogen Cooled Turbine Generator Under Different End Winding Extensions
Extension lengths of the stator and rotor end windings will obviously affect the electromagnetic field, fluid flow, and temperature of end components in the end zone of large water-hydrogen-hydrogen cooled turbine generator. In this paper, a 330 MW water-hydrogen-hydrogen cooled turbine generator is analyzed. Flow network of this turbine generator is established. The fluid velocity and the pressure (boundary conditions) are obtained at the different positions of this turbine generator after solving the equations of flow network. Three-dimensional transient electromagnetic field is calculated in the turbine generator end zone. The leakage magnetic field and the losses (heat source) of end components are determined in the turbine generator end zone under the different lengths of stator and rotor end winding extension. Based on these results, three-dimensional fluid-thermal coupled model is given in the end zone. The distribution of complex fluid velocity in the turbine generator end zone is determined. The temperature distribution of the stator end winding, clamp plate, electric screen, and finger plate is studied under the different lengths of stator and rotor end winding extension. The calculated temperature results agree well with the measured values.
- Open Access
Influence of Control and Structure Parameters on the Starting Performance of a 12/8 Pole Switched Reluctance Motor
To investigate the influence of control and structure parameters on the starting performance of a switched reluctance motor, a 12/8 pole switched reluctance motor is analyzed in this paper. The novel field-circuit coupled finite element method of switched reluctance motor is proposed in the paper. The influence of the controller on the switched reluctance motor is considered. The influence of rotor initial position angle, starting mode, starting current, and structure parameters on the starting performance of the switched reluctance motor is studied using the field-circuit coupled finite element method. The starting performance of the switched reluctance motor is obtained under the different control and structure parameters. The alternating starting mode of single- and two-phase winding can improve the starting torque of switched reluctance motor (SRM). As the stator pole arc coefficient increases, the starting torque of SRM increases. The appropriate reduction of the air gap length can improve the starting torque of SRM. Experimental results of the prototype are compared with the calculation results, which verifies the reliability of the calculation method and accuracy of the calculation results.
Open AccessInfluence of Control and Structure Parameters on the Starting Performance of a 12/8 Pole Switched Reluctance Motor
To investigate the influence of control and structure parameters on the starting performance of a switched reluctance motor, a 12/8 pole switched reluctance motor is analyzed in this paper. The novel field-circuit coupled finite element method of switched reluctance motor is proposed in the paper. The influence of the controller on the switched reluctance motor is considered. The influence of rotor initial position angle, starting mode, starting current, and structure parameters on the starting performance of the switched reluctance motor is studied using the field-circuit coupled finite element method. The starting performance of the switched reluctance motor is obtained under the different control and structure parameters. The alternating starting mode of single- and two-phase winding can improve the starting torque of switched reluctance motor (SRM). As the stator pole arc coefficient increases, the starting torque of SRM increases. The appropriate reduction of the air gap length can improve the starting torque of SRM. Experimental results of the prototype are compared with the calculation results, which verifies the reliability of the calculation method and accuracy of the calculation results.
- Open Access
- 26 March 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 8, 70703-70712
Influence of Extension Length of Rotor End Windings on the Three-Dimensional Electromagnetic Field and Temperature Rise in the Large Turbine Generator End Zone With Magnetic Screen
Leakage magnetic field from the rotor end windings affects obviously the electromagnetic losses and temperature of end components in the turbine generator end zone with magnetic screen. As the capacity of turbine generator increases, this effect of rotor end windings has become more prominent. To investigate influence of the extension length of rotor end windings on the electromagnetic and thermal fields in the turbine generator end zone with magnetic screen, three-dimensional transient electromagnetic field model of 1250 MW turbine generator end zone is given. Leakage magnetic field and losses of end components are compared and studied in the end zone under the different extension lengths of rotor end windings. Based on the calculation results of electromagnetic losses (heat sources) and flow network (boundary conditions), three-dimensional fluid-thermal coupling field is calculated in the turbine generator end zone with magnetic screen. Distribution of complex fluid velocity in the end zone is obtained. Influence of the different extension lengths of rotor end windings on the stator-end copper coil, screen plate, finger plate, press plate, magnetic screen, and stator end core is researched in the turbine generator end zone. The accuracy of calculation results is validated by experimental values.
- 26 March 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 8, 70703-70712
Open AccessInfluence of Extension Length of Rotor End Windings on the Three-Dimensional Electromagnetic Field and Temperature Rise in the Large Turbine Generator End Zone With Magnetic Screen
Leakage magnetic field from the rotor end windings affects obviously the electromagnetic losses and temperature of end components in the turbine generator end zone with magnetic screen. As the capacity of turbine generator increases, this effect of rotor end windings has become more prominent. To investigate influence of the extension length of rotor end windings on the electromagnetic and thermal fields in the turbine generator end zone with magnetic screen, three-dimensional transient electromagnetic field model of 1250 MW turbine generator end zone is given. Leakage magnetic field and losses of end components are compared and studied in the end zone under the different extension lengths of rotor end windings. Based on the calculation results of electromagnetic losses (heat sources) and flow network (boundary conditions), three-dimensional fluid-thermal coupling field is calculated in the turbine generator end zone with magnetic screen. Distribution of complex fluid velocity in the end zone is obtained. Influence of the different extension lengths of rotor end windings on the stator-end copper coil, screen plate, finger plate, press plate, magnetic screen, and stator end core is researched in the turbine generator end zone. The accuracy of calculation results is validated by experimental values.