Jichao Han
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Jichao Han has a total of 51 co-authors. Here are the top co-authors by number of shared publications:
- Baojun Ge
Harbin University of Science and Technology, Harbin, China
10 shared publications Baojun Ge
Harbin University of Science and Technology
8 shared publications- Yutian Sun
Harbin Institute of Large Electrical Machinery, Harbin, China
5 shared publications - Li Weili
Harbin University of Science and Technology, Harbin, China
4 shared publications - Weili Li
Beijing Jiaotong University
4 shared publications - Chao Wang
School of Electrical and Electronic Engineering, Harbin University of Science and Technology, Harbin 150080, China
3 shared publications
Latest Publications
- 29 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Energy Conversion
- Vol. 41 (2) , 1527-1539
Influence of End Structure Optimization on 3D Electromagnetic Field and Losses of a Novel Double-Side Counter-Flow Turbogenerator
Turbogenerators are crucial equipment in power generation. Unreasonable design of the end of such generators can lead increased end losses that can impact the safety and stability of the system in operation. In this study, a 350-MW novel double-side counter-flow large turbogenerator is proposed. A three-dimensional transient nonlinear electromagnetic field model of the end region of the turbogenerator is established to analyze the electromagnetic field. In order to reduce the losses of end components, the novel structural optimization design is proposed. The influence of the modified end structure on the flux density of the end components is investigated by varying the relative lengths of the stator and rotor cores and the distances between the copper screen and windings. The losses of the end components are obtained under different end structures. The results show that a reasonable relative length between the stator and rotor cores and distance between the copper screen and winding effectively reduced losses from end components in the proposed design. The results of the calculation are verified experimentally. Thus, this study provides an important reference for the optimization of the end structures of turbogenerators.
- 29 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Energy Conversion
- Vol. 41 (2) , 1527-1539
Influence of End Structure Optimization on 3D Electromagnetic Field and Losses of a Novel Double-Side Counter-Flow Turbogenerator
Turbogenerators are crucial equipment in power generation. Unreasonable design of the end of such generators can lead increased end losses that can impact the safety and stability of the system in operation. In this study, a 350-MW novel double-side counter-flow large turbogenerator is proposed. A three-dimensional transient nonlinear electromagnetic field model of the end region of the turbogenerator is established to analyze the electromagnetic field. In order to reduce the losses of end components, the novel structural optimization design is proposed. The influence of the modified end structure on the flux density of the end components is investigated by varying the relative lengths of the stator and rotor cores and the distances between the copper screen and windings. The losses of the end components are obtained under different end structures. The results show that a reasonable relative length between the stator and rotor cores and distance between the copper screen and winding effectively reduced losses from end components in the proposed design. The results of the calculation are verified experimentally. Thus, this study provides an important reference for the optimization of the end structures of turbogenerators.
- Open Access
- 1 January 2025
- Published by Institution of Engineering and Technology (IET) in IET Electric Power Applications
- Vol. 19 (1)
Analysis of Electromagnetic Field and Heat Transfer in the End Region of Variable‐Speed Pumped Storage Generator‐Motor at Different Speeds
Large variable‐speed pumped storage generator‐motors (VSPSGMs) offer superior speed adaptability and rapid adjustment capabilities for both active and reactive power. However, their rotor AC excitation systems pose significant challenges for electromagnetic design and ventilation cooling due to variable operational conditions. In this paper, the electromagnetic parameters, ventilation cooling system and heat transfer mechanism of 10 MW VSPSGM are studied. Losses in end components of VSPSGM are obtained at different locations. Fluid velocity distributions are analysed under different speeds. A coupled fluid‐thermal model is developed for the end region of the 10 MW VSPSGM. Complex fluid flow and temperature distribution of end components in the VSPSGM are studied and compared at different speeds. The location of the highest temperature point is obtained. The calculated results are compared with the experimental test values. The ventilation cooling system design and accuracy of the calculation method are verified.
- 1 January 2025
- Published by Institution of Engineering and Technology (IET) in IET Electric Power Applications
- Vol. 19 (1)
Open AccessAnalysis of Electromagnetic Field and Heat Transfer in the End Region of Variable‐Speed Pumped Storage Generator‐Motor at Different Speeds
Large variable‐speed pumped storage generator‐motors (VSPSGMs) offer superior speed adaptability and rapid adjustment capabilities for both active and reactive power. However, their rotor AC excitation systems pose significant challenges for electromagnetic design and ventilation cooling due to variable operational conditions. In this paper, the electromagnetic parameters, ventilation cooling system and heat transfer mechanism of 10 MW VSPSGM are studied. Losses in end components of VSPSGM are obtained at different locations. Fluid velocity distributions are analysed under different speeds. A coupled fluid‐thermal model is developed for the end region of the 10 MW VSPSGM. Complex fluid flow and temperature distribution of end components in the VSPSGM are studied and compared at different speeds. The location of the highest temperature point is obtained. The calculated results are compared with the experimental test values. The ventilation cooling system design and accuracy of the calculation method are verified.
- 17 September 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Energy Conversion
- Vol. 40 (2) , 1225-1236
Influence of Novel Magnetic Screen Structure on Leakage Flux, Losses, and Thermal Field in the End of Turbogenerator
The end leakage flux generated by the current in the end winding of the turbogenerator is large, which has a significant effect on the electromagnetic losses and temperature in the end region. As the capacity of the power and electromagnetic load increase, the end leakage flux increases obviously in the end of the generator. It results in the high eddy current losses in the components of the end region. The turbogenerator produces local overheating, local stress, and other problems in the end. In this paper, the mathematical model of the three-dimensional transient electromagnetic field in the end is developed for a 1407 MVA nuclear turbogenerator. The flux density distribution and losses of the end components under multi-layer magnetic screen structure are studied. A novel magnetic screen with circumferential ventilation duct (MSWCVD) is proposed. The flux density and losses of the end components are compared and analyzed under different depths and widths of circumferential ventilation duct of the multi-layer magnetic screen. The three-dimensional thermal model of the end region is proposed. The fluid-thermal coupling field of the end region of the turbogenerator is calculated and studied. The results are close to the measured values.
- 17 September 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Energy Conversion
- Vol. 40 (2) , 1225-1236
Influence of Novel Magnetic Screen Structure on Leakage Flux, Losses, and Thermal Field in the End of Turbogenerator
The end leakage flux generated by the current in the end winding of the turbogenerator is large, which has a significant effect on the electromagnetic losses and temperature in the end region. As the capacity of the power and electromagnetic load increase, the end leakage flux increases obviously in the end of the generator. It results in the high eddy current losses in the components of the end region. The turbogenerator produces local overheating, local stress, and other problems in the end. In this paper, the mathematical model of the three-dimensional transient electromagnetic field in the end is developed for a 1407 MVA nuclear turbogenerator. The flux density distribution and losses of the end components under multi-layer magnetic screen structure are studied. A novel magnetic screen with circumferential ventilation duct (MSWCVD) is proposed. The flux density and losses of the end components are compared and analyzed under different depths and widths of circumferential ventilation duct of the multi-layer magnetic screen. The three-dimensional thermal model of the end region is proposed. The fluid-thermal coupling field of the end region of the turbogenerator is calculated and studied. The results are close to the measured values.
- 8 April 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Transportation Electrification
- Vol. 11 (1) , 53-62
Coupled Magneto-Thermal Analysis of Spoke-Type Interior Permanent Magnet Synchronous Motor Under the Overload Condition Considering PM Demagnetization
The spoke-type interior permanent magnet synchronous motor (STIPMSM) is used in the drive systems of electric heavy-duty truck. The drive motors are prone to the overload operation when the electric heavy-duty truck climbs a slope or operates under the heavy load. The reliability of motor is a challenge. The sustained overload capacity is an important index of STIPMSM performance. An improved multi-objective nonlinear coupled iterative calculation method for STIPMSM is proposed, which can accurately calculate the performance changes of STIPMSM under different overload conditions. The nonlinearity of the magnetic circuit and the influence of the external conditions on the material performance are considered in this method. A 650kW STIPMSM is studied. The multi-objective nonlinear coupled iterative calculation method is applied to calculate the different overload conditions. The final multi-objective convergence of physical quantities is achieved. The change of electromagnetic field and harmonics is analyzed under different load rates. A method based on nonlinear fitting for maximum sustained overload (MSO) prediction of STIPMSM is proposed. The predicted MSO operating conditions are calculated. The calculated results are agreement with the predicted results. Experiments are conducted on the STIPMSM prototype under different operating conditions. The accuracy of the calculation method is verified.
- 8 April 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Transportation Electrification
- Vol. 11 (1) , 53-62
Coupled Magneto-Thermal Analysis of Spoke-Type Interior Permanent Magnet Synchronous Motor Under the Overload Condition Considering PM Demagnetization
The spoke-type interior permanent magnet synchronous motor (STIPMSM) is used in the drive systems of electric heavy-duty truck. The drive motors are prone to the overload operation when the electric heavy-duty truck climbs a slope or operates under the heavy load. The reliability of motor is a challenge. The sustained overload capacity is an important index of STIPMSM performance. An improved multi-objective nonlinear coupled iterative calculation method for STIPMSM is proposed, which can accurately calculate the performance changes of STIPMSM under different overload conditions. The nonlinearity of the magnetic circuit and the influence of the external conditions on the material performance are considered in this method. A 650kW STIPMSM is studied. The multi-objective nonlinear coupled iterative calculation method is applied to calculate the different overload conditions. The final multi-objective convergence of physical quantities is achieved. The change of electromagnetic field and harmonics is analyzed under different load rates. A method based on nonlinear fitting for maximum sustained overload (MSO) prediction of STIPMSM is proposed. The predicted MSO operating conditions are calculated. The calculated results are agreement with the predicted results. Experiments are conducted on the STIPMSM prototype under different operating conditions. The accuracy of the calculation method is verified.
- Open Access
- 22 November 2023
- Published by Institution of Engineering and Technology (IET) in IET Science, Measurement & Technology
- Vol. 18 (1) , 1-11
Analysis of leakage flux, losses, and temperature in large synchronous generator end zone under the multi‐layer screen thickness based on novel iterative method
The multi‐layer screen is the key component in the large synchronous generator end zone. The leakage flux, losses, and temperature of end components are significantly affected by the thickness of multi‐layer screen in the synchronous generator. To investigate the influence of multi‐layer screen thickness on the end leakage flux, losses, and temperature in the synchronous generator end zone, 1407MVA nuclear power synchronous generator is studied. Three‐dimensional transient electromagnetic field model of synchronous generator end zone is established. Three‐dimensional transient electromagnetic field in the end zone of 1407MVA synchronous generator with the multi‐layer screen is calculated based on the novel iterative method. The flux density of end components is compared and studied in the end zone under the variation of multi‐layer screen thickness. Influence of the different thicknesses of multi‐layer screen on the losses of the shield plate, screen, finger plate, and stator end core is researched. The losses of end components obtained from 3D end electromagnetic field calculation are applied to the end zone as the heat source in the three‐dimensional fluid and thermal coupled field. The temperature distribution of the end components is determined. The accuracy of the calculated results is validated by the experimental values.
- 22 November 2023
- Published by Institution of Engineering and Technology (IET) in IET Science, Measurement & Technology
- Vol. 18 (1) , 1-11
Open AccessAnalysis of leakage flux, losses, and temperature in large synchronous generator end zone under the multi‐layer screen thickness based on novel iterative method
The multi‐layer screen is the key component in the large synchronous generator end zone. The leakage flux, losses, and temperature of end components are significantly affected by the thickness of multi‐layer screen in the synchronous generator. To investigate the influence of multi‐layer screen thickness on the end leakage flux, losses, and temperature in the synchronous generator end zone, 1407MVA nuclear power synchronous generator is studied. Three‐dimensional transient electromagnetic field model of synchronous generator end zone is established. Three‐dimensional transient electromagnetic field in the end zone of 1407MVA synchronous generator with the multi‐layer screen is calculated based on the novel iterative method. The flux density of end components is compared and studied in the end zone under the variation of multi‐layer screen thickness. Influence of the different thicknesses of multi‐layer screen on the losses of the shield plate, screen, finger plate, and stator end core is researched. The losses of end components obtained from 3D end electromagnetic field calculation are applied to the end zone as the heat source in the three‐dimensional fluid and thermal coupled field. The temperature distribution of the end components is determined. The accuracy of the calculated results is validated by the experimental values.
- 29 September 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Energy Conversion
- Vol. 39 (1) , 772-781
Design and Analysis of the High Torque Density Circumferentially Excited Permanent Magnet Motor Based on PSO
In order to further improve the torque density of the permanent magnet motor, a novel 650 kW circumferentially excited permanent magnet (CEPM) motor is proposed and designed. The response surface method and particle swarm optimization (PSO) algorithm are used to obtain the optimal design of the circumferentially excited permanent magnet motor. The electromagnetic performance is analyzed under the different operating conditions. The mathematical model of three-dimensional end transient electromagnetic filed is calculated to obtain the end leakage magnetic flux and end component losses, which provides the heat source for thermal analysis. Novel air-water cooling dual self-circulation ventilation system with the axial-flow fan is proposed. The complex fluid flow and the temperature distribution of each component are determined in the circumferentially excited permanent magnet motor based on three-dimensional fluid-solid thermal coupled model. The highest temperature of the components is determined. This novel ventilation cooling system can effectively take away the heat in the circumferentially excited permanent magnet motor. A prototype of circumferentially excited permanent magnet motor is manufactured. The designs and analyses are validated.
- 29 September 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Energy Conversion
- Vol. 39 (1) , 772-781
Design and Analysis of the High Torque Density Circumferentially Excited Permanent Magnet Motor Based on PSO
In order to further improve the torque density of the permanent magnet motor, a novel 650 kW circumferentially excited permanent magnet (CEPM) motor is proposed and designed. The response surface method and particle swarm optimization (PSO) algorithm are used to obtain the optimal design of the circumferentially excited permanent magnet motor. The electromagnetic performance is analyzed under the different operating conditions. The mathematical model of three-dimensional end transient electromagnetic filed is calculated to obtain the end leakage magnetic flux and end component losses, which provides the heat source for thermal analysis. Novel air-water cooling dual self-circulation ventilation system with the axial-flow fan is proposed. The complex fluid flow and the temperature distribution of each component are determined in the circumferentially excited permanent magnet motor based on three-dimensional fluid-solid thermal coupled model. The highest temperature of the components is determined. This novel ventilation cooling system can effectively take away the heat in the circumferentially excited permanent magnet motor. A prototype of circumferentially excited permanent magnet motor is manufactured. The designs and analyses are validated.