Kara Garrott
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Kara Garrott has a total of 37 co-authors. Here are the top co-authors by number of shared publications:
- Arwa Younis
Cleveland Clinic
2 shared publications - Ayman A. Hussein
Cardiac Electrophysiology Section, Department of Cardiovascular Medicine, Cleveland Clinic, Cleveland, Ohio, USA
2 shared publications - Brendan Koop
Electrophysiology Research & Development Boston Scientific Corporation Marlborough Massachusetts USA
2 shared publications - Chadi Tabaja
Department of Internal Medicine, Cleveland Clinic, Cleveland, Ohio, USA
2 shared publications - David A. Ramirez
Boston Scientific, Corporation: Electrophysiology Research & Development Arden Hills Minnesota USA
2 shared publications - Hiroshi Nakagawa
Department of Cardiovascular Medicine Cleveland Clinic Cleveland Ohio USA
2 shared publications
Latest Publications
- 1 January 2026
- Published by Wolters Kluwer Health in Circulation: Arrhythmia and Electrophysiology
- Vol. 19 (1) , e014157
Factors Influencing Lesion Titration in a Monopolar Pulsed-Field Ablation Point Catheter: A Preclinical Study
BACKGROUND: Despite the rise of pulsed-field ablation (PFA), predicting and titrating lesion geometry remains challenging. This study aimed to find modifiable parameters that can accurately and repeatedly predict focal PFA lesions across a range of dimensions and to develop a model to predict lesion geometry. METHODS: An in vivo study was performed in 9 swine using an investigational dual-energy contact-force focal catheter with local impedance. Ablations were performed endocardially in the right and left ventricles using settings specifically selected to provide a wide range of lesion dimensions. Predefined PFA applications (1, 2, or 4) were delivered while maintaining different contact-force values (5–45 g). Four different voltages were used (1.0, 1.4, 2.0, and 2.2 kV). Following a 1-week survival period, the animals were euthanized for histopathologic examination. RESULTS: In the study characterization data set, a total of 78 PFA lesions were analyzed. Lesion depth ranged from 1.4 mm to 12.3 mm, while lesion width ranged from 3.3 mm to 21.2 mm. All 3 tested parameters—contact force, number of applications, and voltage—demonstrated a positive linear correlation with lesion depth ( P R =0.83; P R =0.76; P <0.0001). A perpendicular catheter orientation was correlated with deeper lesions than a parallel orientation. No ST-segment elevations or sustained ventricular arrhythmias were observed. CONCLUSIONS: Our findings demonstrate that PFA can be effectively titrated and predicted using the Focal FARAPULSE Index Model to create lesions of varying depths (1–12 mm), with these results being specific to the proprietary waveform and catheter used.
- 1 January 2026
- Published by Wolters Kluwer Health in Circulation: Arrhythmia and Electrophysiology
- Vol. 19 (1) , e014157
Factors Influencing Lesion Titration in a Monopolar Pulsed-Field Ablation Point Catheter: A Preclinical Study
BACKGROUND: Despite the rise of pulsed-field ablation (PFA), predicting and titrating lesion geometry remains challenging. This study aimed to find modifiable parameters that can accurately and repeatedly predict focal PFA lesions across a range of dimensions and to develop a model to predict lesion geometry. METHODS: An in vivo study was performed in 9 swine using an investigational dual-energy contact-force focal catheter with local impedance. Ablations were performed endocardially in the right and left ventricles using settings specifically selected to provide a wide range of lesion dimensions. Predefined PFA applications (1, 2, or 4) were delivered while maintaining different contact-force values (5–45 g). Four different voltages were used (1.0, 1.4, 2.0, and 2.2 kV). Following a 1-week survival period, the animals were euthanized for histopathologic examination. RESULTS: In the study characterization data set, a total of 78 PFA lesions were analyzed. Lesion depth ranged from 1.4 mm to 12.3 mm, while lesion width ranged from 3.3 mm to 21.2 mm. All 3 tested parameters—contact force, number of applications, and voltage—demonstrated a positive linear correlation with lesion depth ( P R =0.83; P R =0.76; P <0.0001). A perpendicular catheter orientation was correlated with deeper lesions than a parallel orientation. No ST-segment elevations or sustained ventricular arrhythmias were observed. CONCLUSIONS: Our findings demonstrate that PFA can be effectively titrated and predicted using the Focal FARAPULSE Index Model to create lesions of varying depths (1–12 mm), with these results being specific to the proprietary waveform and catheter used.
- Open Access
- 27 January 2025
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 49 (1) , 32-42
Lesion Formation in Cardiac Pulsed‐Field Ablation: Acute to Chronic Cellular Level Changes
As pulsed‐field ablation (PFA) emerges as a promising therapy for atrial arrhythmias, an understanding of the cellular injury to cardiac tissue is critical to evaluating and interpreting results for each PFA system. This review aims to detail the mechanism of cell death for PFA, compare the cell death mechanism to thermal ablation modalities, clarify common histology markers, detail the progression of PFA lesions from the acute, to subacute, to chronic maturation states, and discuss clinical indicators of PFA lesions.
- 27 January 2025
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 49 (1) , 32-42
Open AccessLesion Formation in Cardiac Pulsed‐Field Ablation: Acute to Chronic Cellular Level Changes
As pulsed‐field ablation (PFA) emerges as a promising therapy for atrial arrhythmias, an understanding of the cellular injury to cardiac tissue is critical to evaluating and interpreting results for each PFA system. This review aims to detail the mechanism of cell death for PFA, compare the cell death mechanism to thermal ablation modalities, clarify common histology markers, detail the progression of PFA lesions from the acute, to subacute, to chronic maturation states, and discuss clinical indicators of PFA lesions.
- Open Access
- 4 November 2024
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 49 (1) , 43-51
Coronary Spasm Due to Pulsed Field Ablation: A State‐of‐the‐Art Review
With the ever‐growing population of patients undergoing cardiac ablation with pulsed electric fields, there is a need to understand secondary effects from the therapy. Coronary artery spasm is one such effect that has recently emerged as the subject of further investigation in electrophysiology literature. This review aims to elucidate the basic anatomy underlying vascular spasm due to pulsed electric fields and the effects of irreversible electroporation on coronary arteries. This review also aims to gather the current preclinical and clinical data regarding the physiology and function of coronary arteries following electroporation.
- 4 November 2024
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 49 (1) , 43-51
Open AccessCoronary Spasm Due to Pulsed Field Ablation: A State‐of‐the‐Art Review
With the ever‐growing population of patients undergoing cardiac ablation with pulsed electric fields, there is a need to understand secondary effects from the therapy. Coronary artery spasm is one such effect that has recently emerged as the subject of further investigation in electrophysiology literature. This review aims to elucidate the basic anatomy underlying vascular spasm due to pulsed electric fields and the effects of irreversible electroporation on coronary arteries. This review also aims to gather the current preclinical and clinical data regarding the physiology and function of coronary arteries following electroporation.
- 1 June 2024
- Published by Wolters Kluwer Health in Circulation: Arrhythmia and Electrophysiology
- Vol. 17 (6) , e012723
Impact of Contact Force on Pulsed Field Ablation Outcomes Using Focal Point Catheter
BACKGROUND: Conventional focal radiofrequency catheters may be modified to enable multiple energy modalities (radiofrequency or pulsed field [PF]) with the benefit of contact force (CF) feedback, providing greater flexibility in the treatment of arrhythmias. Information on the impact of CF on lesion formation in PF ablations remains limited. METHODS: An in vivo study was performed with 8 swine using an investigational dual-energy CF focal catheter with local impedance. Experiment I: To evaluate atrial lesion formation, contiguity, and width, a point-by-point approach was used to create an intercaval line. The distance between the points was prespecified at 4±1 mm. Half of the line was created with radiofrequency energy, whereas the other half utilized PF (single 2.0 kV application with a proprietary waveform). Experiment II: To evaluate single application lesion dimensions with a proprietary waveform, discrete ventricular lesions were performed with PFA (single 2.0 kV application) with targeted levels of CF: low, 5 to 15 g; medium, 20 to 30 g; and high, 35 to 45 g. Following 1 week of survival, animals underwent endocardial/epicardial remapping, and euthanasia to enable histopathologic examination. RESULTS: Experiment I: Both energy modalities resulted in a complete intercaval line of transmural ablation. PF resulted in significantly wider lines than radiofrequency: minimum width, 14.9±2.3 versus 5.0±1.6 mm; maximum width, 21.8±3.4 versus 7.3±2.1 mm, respectively; P P P =0.052; and volume: r=0.55, P <0.001), with depth increasing at a faster rate than width. The mean depths were as follows: low (n=17), 4.3±1.0 mm; medium (n=26), 6.4±1.2 mm; and high (n=14), 9.1±1.4 mm. CONCLUSIONS: Using the same focal point CF-sensing catheter, a novel PF ablation waveform with a single application resulted in transmural atrial lesions that were significantly wider than radiofrequency. Lesion depth showed a significant positive correlation with CF with depths of 6.4 mm at moderate CF.
- 1 June 2024
- Published by Wolters Kluwer Health in Circulation: Arrhythmia and Electrophysiology
- Vol. 17 (6) , e012723
Impact of Contact Force on Pulsed Field Ablation Outcomes Using Focal Point Catheter
BACKGROUND: Conventional focal radiofrequency catheters may be modified to enable multiple energy modalities (radiofrequency or pulsed field [PF]) with the benefit of contact force (CF) feedback, providing greater flexibility in the treatment of arrhythmias. Information on the impact of CF on lesion formation in PF ablations remains limited. METHODS: An in vivo study was performed with 8 swine using an investigational dual-energy CF focal catheter with local impedance. Experiment I: To evaluate atrial lesion formation, contiguity, and width, a point-by-point approach was used to create an intercaval line. The distance between the points was prespecified at 4±1 mm. Half of the line was created with radiofrequency energy, whereas the other half utilized PF (single 2.0 kV application with a proprietary waveform). Experiment II: To evaluate single application lesion dimensions with a proprietary waveform, discrete ventricular lesions were performed with PFA (single 2.0 kV application) with targeted levels of CF: low, 5 to 15 g; medium, 20 to 30 g; and high, 35 to 45 g. Following 1 week of survival, animals underwent endocardial/epicardial remapping, and euthanasia to enable histopathologic examination. RESULTS: Experiment I: Both energy modalities resulted in a complete intercaval line of transmural ablation. PF resulted in significantly wider lines than radiofrequency: minimum width, 14.9±2.3 versus 5.0±1.6 mm; maximum width, 21.8±3.4 versus 7.3±2.1 mm, respectively; P P P =0.052; and volume: r=0.55, P <0.001), with depth increasing at a faster rate than width. The mean depths were as follows: low (n=17), 4.3±1.0 mm; medium (n=26), 6.4±1.2 mm; and high (n=14), 9.1±1.4 mm. CONCLUSIONS: Using the same focal point CF-sensing catheter, a novel PF ablation waveform with a single application resulted in transmural atrial lesions that were significantly wider than radiofrequency. Lesion depth showed a significant positive correlation with CF with depths of 6.4 mm at moderate CF.
- 1 August 2020
- Published by Elsevier in Heart Rhythm
- Vol. 17 (8) , 1371-1380
Combined local impedance and contact force for radiofrequency ablation assessment
- 1 August 2020
- Published by Elsevier in Heart Rhythm
- Vol. 17 (8) , 1371-1380
Combined local impedance and contact force for radiofrequency ablation assessment