David A. Ramirez
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
David A. Ramirez has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
- Brendan Koop
Electrophysiology Research & Development Boston Scientific Corporation Marlborough Massachusetts USA
2 shared publications - Kara Garrott
Electrophysiology Department, Boston Scientific Corporation, Marlborough, MA (S.B., L.L., S.H., R.K., M.M.R., K.G.).
2 shared publications Ann Garlitski
Electrophysiology Research & Development Boston Scientific Corporation Marlborough Massachusetts USA
1 shared publication- Atul Verma
McGill University Health Center, Montréal, Canada (A.V.).
1 shared publication - Damijan Miklavčič
University of Ljubljana
1 shared publication - Daniel C. Sigg
Medtronic, Minneapolis, MN (N.C., L.M., D.C.S.).
1 shared publication
Latest Publications
- Open Access
- 27 January 2025
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 49 (1) , 32-42
Lesion Formation in Cardiac Pulsed‐Field Ablation: Acute to Chronic Cellular Level Changes
As pulsed‐field ablation (PFA) emerges as a promising therapy for atrial arrhythmias, an understanding of the cellular injury to cardiac tissue is critical to evaluating and interpreting results for each PFA system. This review aims to detail the mechanism of cell death for PFA, compare the cell death mechanism to thermal ablation modalities, clarify common histology markers, detail the progression of PFA lesions from the acute, to subacute, to chronic maturation states, and discuss clinical indicators of PFA lesions.
- 27 January 2025
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 49 (1) , 32-42
Open AccessLesion Formation in Cardiac Pulsed‐Field Ablation: Acute to Chronic Cellular Level Changes
As pulsed‐field ablation (PFA) emerges as a promising therapy for atrial arrhythmias, an understanding of the cellular injury to cardiac tissue is critical to evaluating and interpreting results for each PFA system. This review aims to detail the mechanism of cell death for PFA, compare the cell death mechanism to thermal ablation modalities, clarify common histology markers, detail the progression of PFA lesions from the acute, to subacute, to chronic maturation states, and discuss clinical indicators of PFA lesions.
- Open Access
- 4 November 2024
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 49 (1) , 43-51
Coronary Spasm Due to Pulsed Field Ablation: A State‐of‐the‐Art Review
With the ever‐growing population of patients undergoing cardiac ablation with pulsed electric fields, there is a need to understand secondary effects from the therapy. Coronary artery spasm is one such effect that has recently emerged as the subject of further investigation in electrophysiology literature. This review aims to elucidate the basic anatomy underlying vascular spasm due to pulsed electric fields and the effects of irreversible electroporation on coronary arteries. This review also aims to gather the current preclinical and clinical data regarding the physiology and function of coronary arteries following electroporation.
- 4 November 2024
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 49 (1) , 43-51
Open AccessCoronary Spasm Due to Pulsed Field Ablation: A State‐of‐the‐Art Review
With the ever‐growing population of patients undergoing cardiac ablation with pulsed electric fields, there is a need to understand secondary effects from the therapy. Coronary artery spasm is one such effect that has recently emerged as the subject of further investigation in electrophysiology literature. This review aims to elucidate the basic anatomy underlying vascular spasm due to pulsed electric fields and the effects of irreversible electroporation on coronary arteries. This review also aims to gather the current preclinical and clinical data regarding the physiology and function of coronary arteries following electroporation.
- Open Access
- 3 February 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 70 (6) , 1826-1837
A Multiscale Computational Model of Skeletal Muscle Electroporation Validated Using In Situ Porcine Experiments
Objective: The goal of our study was to determine the importance of electric field orientation in an anisotropic muscle tissue for the extent of irreversible electroporation damage by means of an experimentally validated mathematical model. Methods: Electrical pulses were delivered to porcine skeletal muscle in vivo by inserting needle electrodes so that the electric field was applied in direction either parallel or perpendicular to the direction of the muscle fibres. Triphenyl tetrazolium chloride staining was used to determine the shape of the lesions. Next, we used a single cell model to determine the cell-level conductivity during electroporation, and then generalised the calculated conductivity changes to the bulk tissue. Finally, we compared the experimental lesions with the calculated field strength distributions using the Sørensen-Dice similarity coefficient to find the contours of the electric field strength threshold beyond which irreversible damage is thought to occur. Results: Lesions in the parallel group were consistently smaller and narrower than lesions in the perpendicular group. The determined irreversible threshold of electroporation for the selected pulse protocol was 193.4 V/cm with a standard deviation of 42.1 V/cm, and was not dependent on field orientation. Conclusion: Muscle anisotropy is of significant importance when considering electric field distribution in electroporation applications. Significance: The paper presents an important advancement in building up from the current understanding of single cell electroporation to an in silico multiscale model of bulk muscle tissue. The model accounts for anisotropic electrical conductivity and has been validated through experiments in vivo .
- 3 February 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 70 (6) , 1826-1837
Open AccessA Multiscale Computational Model of Skeletal Muscle Electroporation Validated Using In Situ Porcine Experiments
Objective: The goal of our study was to determine the importance of electric field orientation in an anisotropic muscle tissue for the extent of irreversible electroporation damage by means of an experimentally validated mathematical model. Methods: Electrical pulses were delivered to porcine skeletal muscle in vivo by inserting needle electrodes so that the electric field was applied in direction either parallel or perpendicular to the direction of the muscle fibres. Triphenyl tetrazolium chloride staining was used to determine the shape of the lesions. Next, we used a single cell model to determine the cell-level conductivity during electroporation, and then generalised the calculated conductivity changes to the bulk tissue. Finally, we compared the experimental lesions with the calculated field strength distributions using the Sørensen-Dice similarity coefficient to find the contours of the electric field strength threshold beyond which irreversible damage is thought to occur. Results: Lesions in the parallel group were consistently smaller and narrower than lesions in the perpendicular group. The determined irreversible threshold of electroporation for the selected pulse protocol was 193.4 V/cm with a standard deviation of 42.1 V/cm, and was not dependent on field orientation. Conclusion: Muscle anisotropy is of significant importance when considering electric field distribution in electroporation applications. Significance: The paper presents an important advancement in building up from the current understanding of single cell electroporation to an in silico multiscale model of bulk muscle tissue. The model accounts for anisotropic electrical conductivity and has been validated through experiments in vivo .
- 10 September 2022
- Published by Springer Nature in Annals of Biomedical Engineering
- Vol. 51 (3) , 538-549
Nerve Protection During Prostate Cryosurgery
Cryosurgery is a minimally invasive approach to the treatment of focal prostate cancer (PCa). A major complication is the cryoinjury to the cavernous nerve in the neurovascular bundle (NVB). This nerve cryoinjury halts conduction of action potentials (APs) and can eventually result in erectile dysfunction and therefore diminished quality of life for the patient. Here, we propose the application of cryoprotective agents (CPA) to the regions of the nerves in the NVB, prior to prostate cryosurgery, to minimize non-recoverable loss of AP conduction. We modeled a cryosurgical procedure based on data taken during a clinical case and applied ex-vivo porcine phrenic nerves and rat sciatic nerve with temperature profile of NVB. The APs were measured before and after the CPA exposures and during 3 h of recovery. Comparisons of AP amplitude recovery with various CPA compositions reveal that certain CPAs (e.g., 5% DMSO + 7.5% Trehalose and 5% M22 for porcine and rat nerves, respectively) showed little or no toxicity and effective cryoprotection from freezing (on average 48% and 30% of recovered AP, respectively). In summary, we demonstrate that neural conduction can be preserved after exposure to freezing conditions if CPAs are properly selected and deployed onto the nerve.
- 10 September 2022
- Published by Springer Nature in Annals of Biomedical Engineering
- Vol. 51 (3) , 538-549
Nerve Protection During Prostate Cryosurgery
Cryosurgery is a minimally invasive approach to the treatment of focal prostate cancer (PCa). A major complication is the cryoinjury to the cavernous nerve in the neurovascular bundle (NVB). This nerve cryoinjury halts conduction of action potentials (APs) and can eventually result in erectile dysfunction and therefore diminished quality of life for the patient. Here, we propose the application of cryoprotective agents (CPA) to the regions of the nerves in the NVB, prior to prostate cryosurgery, to minimize non-recoverable loss of AP conduction. We modeled a cryosurgical procedure based on data taken during a clinical case and applied ex-vivo porcine phrenic nerves and rat sciatic nerve with temperature profile of NVB. The APs were measured before and after the CPA exposures and during 3 h of recovery. Comparisons of AP amplitude recovery with various CPA compositions reveal that certain CPAs (e.g., 5% DMSO + 7.5% Trehalose and 5% M22 for porcine and rat nerves, respectively) showed little or no toxicity and effective cryoprotection from freezing (on average 48% and 30% of recovered AP, respectively). In summary, we demonstrate that neural conduction can be preserved after exposure to freezing conditions if CPAs are properly selected and deployed onto the nerve.
- Open Access
- 1 July 2021
- Published by Wolters Kluwer Health in Circulation: Arrhythmia and Electrophysiology
- Vol. 14 (7) , 660-668
Assessing the Relationship of Applied Force and Ablation Duration on Lesion Size Using a Diamond Tip Catheter Ablation System
Background - Contact force has proven to be influential for lesion formation in power-controlled radiofrequency (RF) ablation. Lesion formation and morphology from a temperature-controlled diamond tip RF ablation catheter is not well described. We hypothesize that lesion formation from a temperature-controlled RF system is independent of applied force over short application durations. Methods - This study examined lesion depth, surface width, temperature, and ablation parameters of the DiamondTemp Ablation (DTA, Medtronic, Inc.) system for ablation applications delivered with varying application duration (5, 10, and 15 sec) and applied force (5, 10, and 30 g). Lesions from perpendicular RF applications were analyzed in a stepwise fashion from a computational model, thermochromic gel data (n=36), and porcine thigh preparation (n=231) experiments. Results - Varying applied force across each application duration consistently generated comparable lesion dimensions for each model. In the computational model, lesion depths from a 5 sec application with 5, 10, and 30 g of applied force were similar (2.3, 2.6, and 3.0 mm, respectively). Also, the 5 sec lesion depths in the gel model were consistent across applied force (5 g = 3.2±0.1 mm, 10 g = 3.5±0.1 mm, 30 g = 3.5±0.2 mm). In the thigh model, the 5, 10, and 30 g applied forces for 5 sec created lesion depths of 3.1±0.5 mm, 3.2±1.0 mm, and 3.2±1.1 mm, respectively. For the 10 and 15 sec durations, the lesion depth and width remained consistent for the 10 and 30 g applied forces. Increases in lesion depth and width, percentage of impedance reduction, minimum power, and maximum temperature were only significant when application duration increased (from 5 to 15 sec). Conclusions - Lesion dimensions with the DTA temperature-controlled RF ablation system showed no marked change with increased applied force. Short application durations generated consistent lesion dimensions across computational, thermochromic gel, and thighmodels.
- 1 July 2021
- Published by Wolters Kluwer Health in Circulation: Arrhythmia and Electrophysiology
- Vol. 14 (7) , 660-668
Open AccessAssessing the Relationship of Applied Force and Ablation Duration on Lesion Size Using a Diamond Tip Catheter Ablation System
Background - Contact force has proven to be influential for lesion formation in power-controlled radiofrequency (RF) ablation. Lesion formation and morphology from a temperature-controlled diamond tip RF ablation catheter is not well described. We hypothesize that lesion formation from a temperature-controlled RF system is independent of applied force over short application durations. Methods - This study examined lesion depth, surface width, temperature, and ablation parameters of the DiamondTemp Ablation (DTA, Medtronic, Inc.) system for ablation applications delivered with varying application duration (5, 10, and 15 sec) and applied force (5, 10, and 30 g). Lesions from perpendicular RF applications were analyzed in a stepwise fashion from a computational model, thermochromic gel data (n=36), and porcine thigh preparation (n=231) experiments. Results - Varying applied force across each application duration consistently generated comparable lesion dimensions for each model. In the computational model, lesion depths from a 5 sec application with 5, 10, and 30 g of applied force were similar (2.3, 2.6, and 3.0 mm, respectively). Also, the 5 sec lesion depths in the gel model were consistent across applied force (5 g = 3.2±0.1 mm, 10 g = 3.5±0.1 mm, 30 g = 3.5±0.2 mm). In the thigh model, the 5, 10, and 30 g applied forces for 5 sec created lesion depths of 3.1±0.5 mm, 3.2±1.0 mm, and 3.2±1.1 mm, respectively. For the 10 and 15 sec durations, the lesion depth and width remained consistent for the 10 and 30 g applied forces. Increases in lesion depth and width, percentage of impedance reduction, minimum power, and maximum temperature were only significant when application duration increased (from 5 to 15 sec). Conclusions - Lesion dimensions with the DTA temperature-controlled RF ablation system showed no marked change with increased applied force. Short application durations generated consistent lesion dimensions across computational, thermochromic gel, and thighmodels.