MHMohd Kameil Abdul Hamid

Mohd Kameil Abdul Hamid

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Mohd Kameil Abdul Hamid has a total of 9 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Different Behaviors of Friction in Open and Closed Forging Test Utilizing Palm Oil-Based Lubricants

    by Aiman Yahaya, Syahrullail Samion, Ummikalsom Abidin, Mohd Kameil Abdul Hamid

    Increasing demand for manufactured goods in industries such as automobiles, electronics, construction, and aerospace has motivated researchers to develop sustainable manufacturing processes. Most metal-forming lubricants are not eco-friendly; they may cause substantial chemical emissions and constitute a community threat. Bio-oil lubricants are seen as possible replacements for mineral oil-based lubricants. Computational modelling of the forging process uses the finite element method to accelerate and improve design. This research intends to act as a case study and demonstrate how friction behaves differently in open-closed forging tests of different palm oil derivatives. The relationship between the different types of friction was studied using a cold forging test in conjunction with the development of a Coulomb–Tresca friction model. From the results, it can be shown that the friction behavior for the closed forging test (CFT) and the ring compression test (RCT) differs; the CFT exhibits a diversified friction adaptation, while the RCT exhibits a single friction adaptation. From both tests, palm stearin (PS) shows the lowest friction behavior where at RCT the friction is estimated at m = 0.10/μ = 0.05 and the CFT has a varied friction and the average friction is estimated at m = 0.352/μ = 0.1626. On the other hand, commercial metal-forming oil (CMFO) shows the highest lubrication sample in friction, where the value of friction is similar to the no lubricant sample (NA-O), which is (m = 0.45/μ = 0.1875) on the RCT test and (m = 0.424/μ = 0.1681) on the CFT test.


  • Open Access

    Li-NMC Battery Internal Resistance at Wide Range of Temperature Authors

    by Muhammad Fikri Irsyad Mat Razi, Zul Hilmi Che Daud, Zainab Asus, Izhari Izmi Mazali, Mohd Ibthisham Ardani, Mohd Kameil Abdul Hamid

    One of the factors that affects energy transfer by Lithium-ion batteries is internal resistance. This internal resistance occurs due to resistivity of the electrochemical materials and its ionic component. Meanwhile, the internal resistance of a battery is affected by several factors such as temperature and their state of charge. To maintain battery health and prevent rapid degradation, the use of batteries at high temperatures should be avoided. In that relation, studies involving battery internal resistance are mostly conducted in an ideal temperatures range. This makes data on internal resistance at high temperatures scarce and insufficient. Accordingly, this internal resistance data is an important key component in predicting the battery temperature. Good internal resistance data at high temperatures can contribute to a more accurate battery temperature prediction. The purpose of this study is to provide internal resistance data for Li-MNC battery in wide range of temperature by means of experiment. In this study, the temperature of Lithium-ion Manganese-Nickel-Cobalt (Li-MNC) battery with the capacity of 40Ah was raised via high current discharge method. The discharge current used was 120A (3C) and 160A (4C). The discharge temperature was conducted from 26°C to 80°C. Internal resistance is then calculated from the measured voltage respond when 1C (40A) pulse current discharge flow through the battery. Results showed that as temperature increases, the value of internal resistance decreases. At the same time however, the rate of decrement declined until it become almost constant at high temperature range until reaching 80°C. The objective of this study is to provide the data of battery internal resistance at a wide temperature range up to 80°C. This information is important in developing a precise battery electro-thermal model that can predict battery performance and temperature. On the extend of that, this information will be useful in developing better battery management system to ensure good battery usage and safety.


  • Open Access

    A Review of Internal Resistance and Temperature Relationship, State of Health and Thermal Runaway for Lithium-Ion Battery Beyond Normal Operating Condition

    by Muhammad Fikri Irsyad Mat Razi, Zul Hilmi Che Daud, Zainab Asus, Izhari Izmi Mazali, Mohd Ibtisyam Ardani, Mohd Kameil Abdul Hamid

    One of the most popular energy sources in electrical circuitry is the lithium-ion battery (LIB) and it can be found in a variety of products from the smallest unit such as Airpod, smartwatch, smartphone to as big as farming drones, industrial robots, and electric vehicles. But the usage of lithium-ion batteries is limited to a range of temperatures. The normal operating temperature range for LIB is 40°C~65°C. Despite this, there are still cases where operating LIB at high temperature is unavoidable for example deep earth pipeline inspection in the oil & gas industry, sterilization of medical tools in the medical industry, harsh condition robots and drones in the industrial sector, and high ambient power storage for photovoltaic system. Operating LIB beyond normal conditions will affect the battery in several ways. In this paper, the effect of temperature on internal resistance is demonstrated by several studies, the results show LIB internal resistance decrease as temperature increase. Operating LIB beyond normal operating conditions can also lead to faster battery degradation. Battery state of health (SOH) is used to indicate battery degradation level. A battery with a low SOH performs poorly in terms of power delivery compared to a high SOH battery. In addition, operating LIB beyond normal operating conditions, stresses such as thermal stress can damage the battery and instigate thermal runaway causing violent combustion and explosion.