Dingyang Wang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Dingyang Wang has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
- Sung Ho Cho
Department of Electronic Engineering, Hanyang University, Seoul, Republic of Korea
4 shared publications - Sungwon Yoo
Department of Electronics and Computer Engineering, Hanyang University, Seoul 04763, Korea
3 shared publications - Francesco Fioranelli
Microwave Sensing, Signals and Systems (MS3) group, Delft University of Technology, Delft, The Netherlands
2 shared publications Alexander Yarovoy
Microwave Sensing Signals and Systems (MS3) Group, Department of Microelectronics, Delft University of Technology, Delft, The Netherlands
1 shared publication- Chulsoo Lee
Data Link & Positioning System, LIGNex1 Co., Ltd., Seongnam 13488, Korea
1 shared publication - Chulsoo Lee1 shared publication
Latest Publications
- 12 September 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Radar Systems
- Vol. 3, 1298-1308
Grouped Target Tracking and Seamless People Counting With a 24-GHz MIMO FMCW
The problem of radar-based tracking of groups of people moving together and counting their numbers in indoor environments is considered here. A novel processing pipeline to track groups of people moving together and count their numbers is proposed and validated. The pipeline is specifically designed to deal with frequent changes of direction and stop & go movements typical of indoor activities. The proposed approach combines a tracker with a classifier to count the number of grouped people; this uses both spatial features extracted from range-azimuth maps, and Doppler frequency features extracted with wavelet decomposition. Thus, the pipeline outputs over time both the location and number of people present. The proposed approach is verified with experimental data collected with a 24 GHz Frequency Modulated Continuous Wave (FMCW) radar. It is shown that the proposed method achieves 93.15% accuracy in terms of counting the number of people, and a tracking metric OSPA of 0.335. Furthermore, the performance is analyzed as a function of different relevant variables such as feature combinations and scenarios.
- 12 September 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Radar Systems
- Vol. 3, 1298-1308
Grouped Target Tracking and Seamless People Counting With a 24-GHz MIMO FMCW
The problem of radar-based tracking of groups of people moving together and counting their numbers in indoor environments is considered here. A novel processing pipeline to track groups of people moving together and count their numbers is proposed and validated. The pipeline is specifically designed to deal with frequent changes of direction and stop & go movements typical of indoor activities. The proposed approach combines a tracker with a classifier to count the number of grouped people; this uses both spatial features extracted from range-azimuth maps, and Doppler frequency features extracted with wavelet decomposition. Thus, the pipeline outputs over time both the location and number of people present. The proposed approach is verified with experimental data collected with a 24 GHz Frequency Modulated Continuous Wave (FMCW) radar. It is shown that the proposed method achieves 93.15% accuracy in terms of counting the number of people, and a tracking metric OSPA of 0.335. Furthermore, the performance is analyzed as a function of different relevant variables such as feature combinations and scenarios.
- Open Access
- 26 February 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Microwave Theory and Techniques
- Vol. 73 (8) , 4340-4350
Gait Symmetry Analysis With FMCW MIMO Radar
Monitoring gait symmetry reliably is crucial, as it is an early indicator of Parkinson’s disease (PD). In this work, a method is presented to analyze gait asymmetries using a 24-GHz frequency-modulated continuous-wave (FMCW) multiple-input–multiple-output (MIMO) radar in a nonclinical environment. The proposed method is validated by analyzing the gait of 60 people recorded in an environment that presents multiple challenges such as multipath, gait interruption events, and different trajectories, which cause aspect angle variability. This article presents algorithms to address these challenges to extract useful gait information from the radar data and discusses the performance of the proposed system, analyzing the ratio of correct feet identifications and the accuracy of the asymmetry gait parameters. It achieved a mean absolute error of the symmetry ratio below 8% for all gait parameters. This shows that the proposed system and algorithms are robust for both clinical and in-home implementations.
- 26 February 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Microwave Theory and Techniques
- Vol. 73 (8) , 4340-4350
Open AccessGait Symmetry Analysis With FMCW MIMO Radar
Monitoring gait symmetry reliably is crucial, as it is an early indicator of Parkinson’s disease (PD). In this work, a method is presented to analyze gait asymmetries using a 24-GHz frequency-modulated continuous-wave (FMCW) multiple-input–multiple-output (MIMO) radar in a nonclinical environment. The proposed method is validated by analyzing the gait of 60 people recorded in an environment that presents multiple challenges such as multipath, gait interruption events, and different trajectories, which cause aspect angle variability. This article presents algorithms to address these challenges to extract useful gait information from the radar data and discusses the performance of the proposed system, analyzing the ratio of correct feet identifications and the accuracy of the asymmetry gait parameters. It achieved a mean absolute error of the symmetry ratio below 8% for all gait parameters. This shows that the proposed system and algorithms are robust for both clinical and in-home implementations.
- Open Access
- 4 October 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 9, 138496-138508
Noncontact Extraction of Biomechanical Parameters in Gait Analysis Using a Multi-Input and Multi-Output Radar Sensor
Gait analysis is one of the most basic methods for assessing a patient’s biopsychological status. Doctors can distinguish people with mental and neurological disorders by monitoring their gait. To perform gait analysis in a more quantitative and accurate manner, many studies have used inertial measurement units (IMUs), cameras and ground reaction force platforms. However, conventional gait analysis requires sensors to be attached to the subject’s body, and some of them are cost prohibitive. Currently, studies of noncontact gait analysis using radar sensors are being performed. Such studies have successfully measured several gait parameters associated with the noncontact method but have been unable to distinguish between individual legs. In this study, we proposed a method for noncontact gait analysis with a treadmill that could separate the left and right legs using multi-input and multi-output frequency-modulated continuous-wave (MIMO FMCW) radar. By recognizing two legs in a range-Doppler map and estimating their angles, ranges and velocities, the gait parameters of the individual legs could be identified. We performed experiments with 15 participants in 4 scenarios (walking, running, left leg limping, right leg limping) and compared gait parameters obtained using FMCW radar and IMUs. The gait parameter measurements were validated using the intraclass correlation value, and they showed excellent agreement except for flight time. Moreover, a parameter was identified that can accurately detect gait asymmetry, and its sensitivity (0.83) and specificity (1.00) were validated. Our future research will analyze not only feet movement but also arm movement so that it can be further applied to the medical field.
- 4 October 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 9, 138496-138508
Open AccessNoncontact Extraction of Biomechanical Parameters in Gait Analysis Using a Multi-Input and Multi-Output Radar Sensor
Gait analysis is one of the most basic methods for assessing a patient’s biopsychological status. Doctors can distinguish people with mental and neurological disorders by monitoring their gait. To perform gait analysis in a more quantitative and accurate manner, many studies have used inertial measurement units (IMUs), cameras and ground reaction force platforms. However, conventional gait analysis requires sensors to be attached to the subject’s body, and some of them are cost prohibitive. Currently, studies of noncontact gait analysis using radar sensors are being performed. Such studies have successfully measured several gait parameters associated with the noncontact method but have been unable to distinguish between individual legs. In this study, we proposed a method for noncontact gait analysis with a treadmill that could separate the left and right legs using multi-input and multi-output frequency-modulated continuous-wave (MIMO FMCW) radar. By recognizing two legs in a range-Doppler map and estimating their angles, ranges and velocities, the gait parameters of the individual legs could be identified. We performed experiments with 15 participants in 4 scenarios (walking, running, left leg limping, right leg limping) and compared gait parameters obtained using FMCW radar and IMUs. The gait parameter measurements were validated using the intraclass correlation value, and they showed excellent agreement except for flight time. Moreover, a parameter was identified that can accurately detect gait asymmetry, and its sensitivity (0.83) and specificity (1.00) were validated. Our future research will analyze not only feet movement but also arm movement so that it can be further applied to the medical field.
- Open Access
Experimental Comparison of IR-UWB Radar and FMCW Radar for Vital Signs
In this paper, we compare the performances of impulse radio ultra-wideband (IR-UWB) and frequency modulation continuous wave (FMCW) radars in measuring noncontact vital signs such as respiration rate and heart rate. These two type radars have been widely used in various fields and have shown their applicability to extract vital signs in noncontact ways. IR-UWB radar can extract vital signs using distance information. On the other hand, FMCW radar requires phase information to estimate vital signs, and the result can be enhanced with Multi-input Multi-output (MIMO) antenna topologies. By using commercial radar chipsets, the operation of radars under different conditions and frequency bands will also affect the performance of vital sign detection capabilities. We compared the accuracy and signal-to-noise (SNR) ratios of IR-UWB and FMCW radars in various scenarios, such as distance, orientation, carotid pulse, harmonics, and obstacle penetration. In general, the IR-UWB radars offer a slightly better accuracy and higher SNR in comparison to FMCW radar. However, each radar system has its own unique advantages, with IR-UWB exhibiting fewer harmonics and a higher SNR, while FMCW can combine the results from each channel.
Open AccessExperimental Comparison of IR-UWB Radar and FMCW Radar for Vital Signs
In this paper, we compare the performances of impulse radio ultra-wideband (IR-UWB) and frequency modulation continuous wave (FMCW) radars in measuring noncontact vital signs such as respiration rate and heart rate. These two type radars have been widely used in various fields and have shown their applicability to extract vital signs in noncontact ways. IR-UWB radar can extract vital signs using distance information. On the other hand, FMCW radar requires phase information to estimate vital signs, and the result can be enhanced with Multi-input Multi-output (MIMO) antenna topologies. By using commercial radar chipsets, the operation of radars under different conditions and frequency bands will also affect the performance of vital sign detection capabilities. We compared the accuracy and signal-to-noise (SNR) ratios of IR-UWB and FMCW radars in various scenarios, such as distance, orientation, carotid pulse, harmonics, and obstacle penetration. In general, the IR-UWB radars offer a slightly better accuracy and higher SNR in comparison to FMCW radar. However, each radar system has its own unique advantages, with IR-UWB exhibiting fewer harmonics and a higher SNR, while FMCW can combine the results from each channel.
- Open Access
- 31 March 2020
- Published by Korean Institute of Electromagnetic Engineering and Science in The Journal of Korean Institute of Electromagnetic Engineering and Science
- Vol. 31 (3) , 301-318
New Detection Algorithm for a Through-Wall Radar System
한국전자파학회논문지 (The Journal of Korean Institute of Electromagnetic Engineering and Science)
- 31 March 2020
- Published by Korean Institute of Electromagnetic Engineering and Science in The Journal of Korean Institute of Electromagnetic Engineering and Science
- Vol. 31 (3) , 301-318
Open AccessNew Detection Algorithm for a Through-Wall Radar System
한국전자파학회논문지 (The Journal of Korean Institute of Electromagnetic Engineering and Science)
- Open Access
A Multiple Target Positioning and Tracking System Behind Brick-Concrete Walls Using Multiple Monostatic IR-UWB Radars
Recognizing and tracking the targets located behind walls through impulse radio ultra-wideband (IR-UWB) radar provides a significant advantage, as the characteristics of the IR-UWB radar signal enable it to penetrate obstacles. In this study, we design a through-wall radar system to estimate and track multiple targets behind a wall. The radar signal received through the wall experiences distortion, such as attenuation and delay, and the characteristics of the wall are estimated to compensate the distance error. In addition, unlike general cases, it is difficult to maintain a high detection rate and low false alarm rate in this through-wall radar application due to the attenuation and distortion caused by the wall. In particular, the generally used delay-and-sum algorithm is significantly affected by the motion of targets and distortion caused by the wall, rendering it difficult to obtain a good performance. Thus, we propose a novel method, which calculates the likelihood that a target exists in a certain location through a detection process. Unlike the delay-and-sum algorithm, this method does not use the radar signal directly. Simulations and experiments are conducted in different cases to show the validity of our through-wall radar system. The results obtained by using the proposed algorithm as well as delay-and-sum and trilateration are compared in terms of the detection rate, false alarm rate, and positioning error.
Open AccessA Multiple Target Positioning and Tracking System Behind Brick-Concrete Walls Using Multiple Monostatic IR-UWB Radars
Recognizing and tracking the targets located behind walls through impulse radio ultra-wideband (IR-UWB) radar provides a significant advantage, as the characteristics of the IR-UWB radar signal enable it to penetrate obstacles. In this study, we design a through-wall radar system to estimate and track multiple targets behind a wall. The radar signal received through the wall experiences distortion, such as attenuation and delay, and the characteristics of the wall are estimated to compensate the distance error. In addition, unlike general cases, it is difficult to maintain a high detection rate and low false alarm rate in this through-wall radar application due to the attenuation and distortion caused by the wall. In particular, the generally used delay-and-sum algorithm is significantly affected by the motion of targets and distortion caused by the wall, rendering it difficult to obtain a good performance. Thus, we propose a novel method, which calculates the likelihood that a target exists in a certain location through a detection process. Unlike the delay-and-sum algorithm, this method does not use the radar signal directly. Simulations and experiments are conducted in different cases to show the validity of our through-wall radar system. The results obtained by using the proposed algorithm as well as delay-and-sum and trilateration are compared in terms of the detection rate, false alarm rate, and positioning error.