P. S. Ganesh Subramanian
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
P. S. Ganesh Subramanian has a total of 72 co-authors. Here are the top co-authors by number of shared publications:
- Vishal Verma
University of Illinois Urbana−Champaign, 205 N Mathews Ave
6 shared publications Vishal Verma
4 shared publications- Lakshminarayana Rao
Centre for Sustainable Technologies, Indian Institute of Science, Bangalore, India
3 shared publications - Saman Haratian
Illinois Institute of Technology 3201 S Dearborn St
3 shared publications Aditi Jain
Centre for BioSystems Science and Engineering Indian Institute of Science Bangalore Karnataka India
2 shared publications- Anand M. Shivapuji
Centre for Sustainable Technologies, Indian Institute of Science, Bengaluru, India
2 shared publications
Latest Publications
- 5 November 2026
- Published by American Chemical Society (ACS) in Environmental Science & Technology
Size- and Time-Resolved Emission Rates of Particulate Matter Mass, Chemical Constituents, and Oxidative Potential from Indoor Sources
We quantified the time- and size-resolved emission rates of particulate matter (PM) mass, its chemical constituents, and OP (via dithiothreitol assay) from six indoor sources in a test chamber (two types of incense, candle, toaster, humidifier, and cigarette). Both the chemical composition and mass-normalized OP (OPm) varied little temporally. However, both the chemical composition and OPm varied with particle size from <0.25 to 10 μm, with quasi-ultrafine particles (Q-UFPs < 0.25 μm) showing the highest OPm. The particle size distribution of the PM emitted from these sources was mostly unimodal, with both PM10 mass and OP emission rate concentrated in the Q-UFP size range. Given the abundance of Q-UFPs in the emitted PM with their high intrinsic OP, we find that 37 ± 3% of the emitted PM10 mass and OP from these sources has the potential to deposit in the respiratory tract, 45 ± 2% of which deposits in the alveolar region. An exploratory exposure assessment suggests that for an equal dose of PM10 mass and OP originating from these indoor sources vs ambient PM, the emissions from the tested indoor sources will likely result in a 76 ± 10% higher dose of alveolar-deposited mass and OP. Collectively, these results emphasize the need to better quantify the size-resolved toxicological properties of PM from myriad indoor emission sources to reliably estimate the resulting health risks.
- 5 November 2026
- Published by American Chemical Society (ACS) in Environmental Science & Technology
Size- and Time-Resolved Emission Rates of Particulate Matter Mass, Chemical Constituents, and Oxidative Potential from Indoor Sources
We quantified the time- and size-resolved emission rates of particulate matter (PM) mass, its chemical constituents, and OP (via dithiothreitol assay) from six indoor sources in a test chamber (two types of incense, candle, toaster, humidifier, and cigarette). Both the chemical composition and mass-normalized OP (OPm) varied little temporally. However, both the chemical composition and OPm varied with particle size from <0.25 to 10 μm, with quasi-ultrafine particles (Q-UFPs < 0.25 μm) showing the highest OPm. The particle size distribution of the PM emitted from these sources was mostly unimodal, with both PM10 mass and OP emission rate concentrated in the Q-UFP size range. Given the abundance of Q-UFPs in the emitted PM with their high intrinsic OP, we find that 37 ± 3% of the emitted PM10 mass and OP from these sources has the potential to deposit in the respiratory tract, 45 ± 2% of which deposits in the alveolar region. An exploratory exposure assessment suggests that for an equal dose of PM10 mass and OP originating from these indoor sources vs ambient PM, the emissions from the tested indoor sources will likely result in a 76 ± 10% higher dose of alveolar-deposited mass and OP. Collectively, these results emphasize the need to better quantify the size-resolved toxicological properties of PM from myriad indoor emission sources to reliably estimate the resulting health risks.
- 9 December 2025
- Published by American Chemical Society (ACS) in ACS ES&T Air
- Vol. 3 (1) , 186-196
Chemical and Oxidative Properties of Indoor PM: Discerning the Influence of Typical Building and Source Characteristics
- 9 December 2025
- Published by American Chemical Society (ACS) in ACS ES&T Air
- Vol. 3 (1) , 186-196
Chemical and Oxidative Properties of Indoor PM: Discerning the Influence of Typical Building and Source Characteristics
- 9 September 2025
- Published by American Chemical Society (ACS) in ACS ES&T Air
- Vol. 2 (10) , 2238-2250
Impacts of the 2023 Canadian Wildfires on the Oxidative Potential of Particulate Matter
- 9 September 2025
- Published by American Chemical Society (ACS) in ACS ES&T Air
- Vol. 2 (10) , 2238-2250
Impacts of the 2023 Canadian Wildfires on the Oxidative Potential of Particulate Matter
- 16 June 2025
- Published by American Chemical Society (ACS) in Environmental Science & Technology
- Vol. 59 (25) , 12797-12811
Oxidative Potential from Common Indoor Sources of Particulate Matter
Although people spend nearly 90% of their time indoors, the source-specific oxidative potential (OP) from indoor emissions spanning multiple particle generation mechanisms is largely unknown. Here, we quantify the OP of the PM originating from commonly used indoor sources via three different assays, i.e., dithiothreitol consumption (OPDTT), glutathione consumption (OPGSH), and hydroxyl radical generation (OPOH). The intrinsic (mass-normalized) OPm of several sources (candles, incense, cigarettes, humidifiers using tap water, toasters, and air fryers) were comparable (0.75-1.25×) or exceeded (1-6×) that of typical ambient PM2.5. Emissions from candles in the presence of a wind-draft had the highest OPDTTm and OPOHm while OPGSHm was highest for cigarette emissions. Elemental carbon determined the OP of PM emitted from sources undergoing incomplete combustion, whereas, for noncombustion sources (water evaporation and heating-based), metals were the important drivers. An exploratory exposure assessment in a hypothetical apartment (volume = 100 m3, air change rate = 0.45 h-1, and penetration coefficient = 0.6) revealed that certain sources (e.g., incense, cigarettes, toasters, and air-fryers) could result in occupants being exposed to higher OP in less than 1 h of indoor operation than that resulting from inhaling typical U.S. ambient PM2.5 (8 μg/m3) over an entire day. Collectively, these results demonstrate the importance of indoor emissions, emphasizing the need for more comprehensive health impact assessments to assist in the development of policy recommendations aimed at mitigating indoor PM exposure.
- 16 June 2025
- Published by American Chemical Society (ACS) in Environmental Science & Technology
- Vol. 59 (25) , 12797-12811
Oxidative Potential from Common Indoor Sources of Particulate Matter
Although people spend nearly 90% of their time indoors, the source-specific oxidative potential (OP) from indoor emissions spanning multiple particle generation mechanisms is largely unknown. Here, we quantify the OP of the PM originating from commonly used indoor sources via three different assays, i.e., dithiothreitol consumption (OPDTT), glutathione consumption (OPGSH), and hydroxyl radical generation (OPOH). The intrinsic (mass-normalized) OPm of several sources (candles, incense, cigarettes, humidifiers using tap water, toasters, and air fryers) were comparable (0.75-1.25×) or exceeded (1-6×) that of typical ambient PM2.5. Emissions from candles in the presence of a wind-draft had the highest OPDTTm and OPOHm while OPGSHm was highest for cigarette emissions. Elemental carbon determined the OP of PM emitted from sources undergoing incomplete combustion, whereas, for noncombustion sources (water evaporation and heating-based), metals were the important drivers. An exploratory exposure assessment in a hypothetical apartment (volume = 100 m3, air change rate = 0.45 h-1, and penetration coefficient = 0.6) revealed that certain sources (e.g., incense, cigarettes, toasters, and air-fryers) could result in occupants being exposed to higher OP in less than 1 h of indoor operation than that resulting from inhaling typical U.S. ambient PM2.5 (8 μg/m3) over an entire day. Collectively, these results demonstrate the importance of indoor emissions, emphasizing the need for more comprehensive health impact assessments to assist in the development of policy recommendations aimed at mitigating indoor PM exposure.
- Open Access
- 21 May 2025
- Published by American Society for Microbiology in Applied and Environmental Microbiology
- Vol. 91 (5) , e0231924
Capsid and genome damage are the leading inactivation mechanisms of aerosolized porcine respiratory coronavirus at different relative humidities
Relative humidity (RH) varies widely in indoor environments based on temperature, outdoor humidity, heating systems, and other environmental conditions. This study explored how RH affects aerosolized porcine respiratory coronavirus (PRCV), a model for coronaviruses, over a time range from 0 min to a maximum of 1 h, and the molecular mechanism behind viral infectivity reduction. These questions were answered by quantifying: (i) viral-host receptor interactions, (ii) capsid integrity, (iii) viral genome integrity, and (iv) virus infectivity. We found RH did not alter PRCV-receptor interactions. RHs 45–55% and 65–75% damaged viral genomes (2 log 10 reduction and 1 log 10 reduction, respectively, in terms of median sample value), whereas RHs 55–65% decreased capsid integrity (2 log 10 reduction). No apparent virion damage was observed in RH 75–85%. Two assays were used to quantify virus presence: qPCR for detecting the viral genomes and plaque-forming unit assay for detecting the virus replication. Our results indicated that the qPCR assay overestimated the concentrations of infectious viruses, and RNase treatment with long-range RT-qPCR performed better than one-step RT-qPCR. We propose that understanding the influence of RH on the stability of aerosolized viruses provides critical information for detecting and preventing the indoor transmission of coronaviruses. IMPORTANCE: Indoor environments can impact the stability of respiratory viruses, which can then affect the transmission rates. The mechanisms of how relative humidity (RH) affects virus infectivity still remain unclear. This study found RH inactivates porcine respiratory coronavirus by damaging its capsid and genome. The finding highlights the potential role of controlling indoor RH levels as a strategy to reduce the risk of coronavirus transmission.
- 21 May 2025
- Published by American Society for Microbiology in Applied and Environmental Microbiology
- Vol. 91 (5) , e0231924
Open AccessCapsid and genome damage are the leading inactivation mechanisms of aerosolized porcine respiratory coronavirus at different relative humidities
Relative humidity (RH) varies widely in indoor environments based on temperature, outdoor humidity, heating systems, and other environmental conditions. This study explored how RH affects aerosolized porcine respiratory coronavirus (PRCV), a model for coronaviruses, over a time range from 0 min to a maximum of 1 h, and the molecular mechanism behind viral infectivity reduction. These questions were answered by quantifying: (i) viral-host receptor interactions, (ii) capsid integrity, (iii) viral genome integrity, and (iv) virus infectivity. We found RH did not alter PRCV-receptor interactions. RHs 45–55% and 65–75% damaged viral genomes (2 log 10 reduction and 1 log 10 reduction, respectively, in terms of median sample value), whereas RHs 55–65% decreased capsid integrity (2 log 10 reduction). No apparent virion damage was observed in RH 75–85%. Two assays were used to quantify virus presence: qPCR for detecting the viral genomes and plaque-forming unit assay for detecting the virus replication. Our results indicated that the qPCR assay overestimated the concentrations of infectious viruses, and RNase treatment with long-range RT-qPCR performed better than one-step RT-qPCR. We propose that understanding the influence of RH on the stability of aerosolized viruses provides critical information for detecting and preventing the indoor transmission of coronaviruses. IMPORTANCE: Indoor environments can impact the stability of respiratory viruses, which can then affect the transmission rates. The mechanisms of how relative humidity (RH) affects virus infectivity still remain unclear. This study found RH inactivates porcine respiratory coronavirus by damaging its capsid and genome. The finding highlights the potential role of controlling indoor RH levels as a strategy to reduce the risk of coronavirus transmission.
- Open Access
- 19 June 2024
- Published by Springer Nature in Nature Communications
- Vol. 15 (1) , 1-13
Inter-continental variability in the relationship of oxidative potential and cytotoxicity with PM2.5 mass
Most fine ambient particulate matter (PM2.5)-based epidemiological models use globalized concentration-response (CR) functions assuming that the toxicity of PM2.5 is solely mass-dependent without considering its chemical composition. Although oxidative potential (OP) has emerged as an alternate metric of PM2.5 toxicity, the association between PM2.5 mass and OP on a large spatial extent has not been investigated. In this study, we evaluate this relationship using 385 PM2.5 samples collected from 14 different sites across 4 different continents and using 5 different OP (and cytotoxicity) endpoints. Our results show that the relationship between PM2.5 mass vs. OP (and cytotoxicity) is largely non-linear due to significant differences in the intrinsic toxicity, resulting from a spatially heterogeneous chemical composition of PM2.5. These results emphasize the need to develop localized CR functions incorporating other measures of PM2.5 properties (e.g., OP) to better predict the PM2.5-attributed health burdens.
- 19 June 2024
- Published by Springer Nature in Nature Communications
- Vol. 15 (1) , 1-13
Open AccessInter-continental variability in the relationship of oxidative potential and cytotoxicity with PM2.5 mass
Most fine ambient particulate matter (PM2.5)-based epidemiological models use globalized concentration-response (CR) functions assuming that the toxicity of PM2.5 is solely mass-dependent without considering its chemical composition. Although oxidative potential (OP) has emerged as an alternate metric of PM2.5 toxicity, the association between PM2.5 mass and OP on a large spatial extent has not been investigated. In this study, we evaluate this relationship using 385 PM2.5 samples collected from 14 different sites across 4 different continents and using 5 different OP (and cytotoxicity) endpoints. Our results show that the relationship between PM2.5 mass vs. OP (and cytotoxicity) is largely non-linear due to significant differences in the intrinsic toxicity, resulting from a spatially heterogeneous chemical composition of PM2.5. These results emphasize the need to develop localized CR functions incorporating other measures of PM2.5 properties (e.g., OP) to better predict the PM2.5-attributed health burdens.
- 26 March 2024
- Published by American Chemical Society (ACS) in ACS ES&T Air
- Vol. 1 (5) , 386-396
Influence of Human Activities and Occupancy on the Emission of Indoor Particles from Respiratory and Nonrespiratory Sources
- 26 March 2024
- Published by American Chemical Society (ACS) in ACS ES&T Air
- Vol. 1 (5) , 386-396
Influence of Human Activities and Occupancy on the Emission of Indoor Particles from Respiratory and Nonrespiratory Sources
- 14 December 2023
- Published by Elsevier in Environmental Pollution
- Vol. 343, 123165
Identifying urban emission sources and their contribution to the oxidative potential of fine particulate matter (PM2.5) in Kuwait.
- 14 December 2023
- Published by Elsevier in Environmental Pollution
- Vol. 343, 123165
Identifying urban emission sources and their contribution to the oxidative potential of fine particulate matter (PM2.5) in Kuwait.