SHSaman Haratian

Saman Haratian

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Saman Haratian has a total of 14 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Size- and Time-Resolved Emission Rates of Particulate Matter Mass, Chemical Constituents, and Oxidative Potential from Indoor Sources

    by P. S. Ganesh Subramanian, Anson Regi, Saman Haratian, Mohammad Heidarinejad, Brent Stephens, Vishal Verma

    We quantified the time- and size-resolved emission rates of particulate matter (PM) mass, its chemical constituents, and OP (via dithiothreitol assay) from six indoor sources in a test chamber (two types of incense, candle, toaster, humidifier, and cigarette). Both the chemical composition and mass-normalized OP (OPm) varied little temporally. However, both the chemical composition and OPm varied with particle size from <0.25 to 10 μm, with quasi-ultrafine particles (Q-UFPs < 0.25 μm) showing the highest OPm. The particle size distribution of the PM emitted from these sources was mostly unimodal, with both PM10 mass and OP emission rate concentrated in the Q-UFP size range. Given the abundance of Q-UFPs in the emitted PM with their high intrinsic OP, we find that 37 ± 3% of the emitted PM10 mass and OP from these sources has the potential to deposit in the respiratory tract, 45 ± 2% of which deposits in the alveolar region. An exploratory exposure assessment suggests that for an equal dose of PM10 mass and OP originating from these indoor sources vs ambient PM, the emissions from the tested indoor sources will likely result in a 76 ± 10% higher dose of alveolar-deposited mass and OP. Collectively, these results emphasize the need to better quantify the size-resolved toxicological properties of PM from myriad indoor emission sources to reliably estimate the resulting health risks.

  • An integral approach to quantifying equivalent clean airflow rates of indoor air cleaning devices from pollutant injection and decay tests

    by Saman Haratian, Paul Dhununjay Claude Chittoo, P.S. Ganesh Subramanian, Vishal Verma, Mohammad Heidarinejad, Brent Stephens, Max Sherman


  • Oxidative Potential from Common Indoor Sources of Particulate Matter

    by P. S. Ganesh Subramanian, Zhuying Dai, Saman Haratian, Mohammad Heidarinejad, Brent Stephens, Vishal Verma

    Although people spend nearly 90% of their time indoors, the source-specific oxidative potential (OP) from indoor emissions spanning multiple particle generation mechanisms is largely unknown. Here, we quantify the OP of the PM originating from commonly used indoor sources via three different assays, i.e., dithiothreitol consumption (OPDTT), glutathione consumption (OPGSH), and hydroxyl radical generation (OPOH). The intrinsic (mass-normalized) OPm of several sources (candles, incense, cigarettes, humidifiers using tap water, toasters, and air fryers) were comparable (0.75-1.25×) or exceeded (1-6×) that of typical ambient PM2.5. Emissions from candles in the presence of a wind-draft had the highest OPDTTm and OPOHm while OPGSHm was highest for cigarette emissions. Elemental carbon determined the OP of PM emitted from sources undergoing incomplete combustion, whereas, for noncombustion sources (water evaporation and heating-based), metals were the important drivers. An exploratory exposure assessment in a hypothetical apartment (volume = 100 m3, air change rate = 0.45 h-1, and penetration coefficient = 0.6) revealed that certain sources (e.g., incense, cigarettes, toasters, and air-fryers) could result in occupants being exposed to higher OP in less than 1 h of indoor operation than that resulting from inhaling typical U.S. ambient PM2.5 (8 μg/m3) over an entire day. Collectively, these results demonstrate the importance of indoor emissions, emphasizing the need for more comprehensive health impact assessments to assist in the development of policy recommendations aimed at mitigating indoor PM exposure.


  • Design and demonstration of a prototype thermally active student desk in a modern landmark for personalized cooling retrofits

    by Lobna Mitkees, Saman Haratian, Saeed Farhoodi, Michelangelo Sabatino, Brent Stephens, Mohammad Heidarinejad

    Modern comfort standards generally assume that human perception of thermal comfort in buildings is steady in space and time. However, satisfying thermal comfort needs of all occupants is often chal...