Akira Madarame
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Akira Madarame has a total of 39 co-authors. Here are the top co-authors by number of shared publications:
- Akiho Hanzawa
Department of Laboratory Medicine and Clinical Investigation, Yokohama City University Medical Center, Yokohama 232-0024, Japan
1 shared publication - Atsuhiro Hirayama
Inflammatory Bowel Disease Center, Yokohama City University Medical Center, Yokohama 232-0024, Japan
1 shared publication - Aya Ikeda
Department of Gastroenterology, Yokohama City University Graduate School of Medicine, 3-9 Fukuura Kanazawa-Ku, Yokohama 236-0004, Japan
1 shared publication - Feiqian Wang
Department of Ultrasound, The First Affiliated Hospital of Xi'an Jiaotong University, Xi'an, Shaanxi, China
1 shared publication - Fumito Yamanishi
Department of Gastroenterology and Hepatology, Tokyo Medical University Hospital, Tokyo, Japan, Japan
1 shared publication - Haruki Kaizuka
Department of Gastroenterology and Hepatology, Tokyo Medical University Hospital, Tokyo, Japan, Japan
1 shared publication
Latest Publications
- Open Access
- 22 September 2026
- Published by MDPI AG in Preprints.org
Salivary Polyamines Are Effective Biomarkers for Gastric Cancer Detection
Background/Objectives: Gastric cancer (GC) is one of the most prevalent malignancies worldwide, highlighting the need for minimally invasive and highly accurate screening methods for its early detection. We evaluated the utility of salivary polyamine-based metabolomic analysis for distinguishing individuals with GC from those without GC. Methods: A total of 53 patients with GC and 37 non-GC controls were included. Participants were recruited from individuals who underwent upper gastrointestinal endoscopy at Tokyo Medical University Hospital between March 2020 and May 2025 and provided saliva samples on the same day. Participants with factors known to affect polyamine levels were excluded. Salivary metabolites quantified by liquid chromatography–mass spectrometry were statistically compared between groups. Acetylated-to-non-acetylated polyamine ratios were used as features to construct a logistic regression-based machine learning model, and discriminative performance was evaluated using receiver operating characteristic analysis. Results: The GC group showed significantly higher concentrations of salivary metabolites. Among individual polyamines, N1-acetylspermine demonstrated the highest discriminative ability (AUC = 0.845). When acetylated-to-non-acetylated polyamine ratios were analyzed, significant differences between groups were observed for N1,N8-diacetylspermidine/spermidine and N1-acetylspermine/spermine. A logistic regression model constructed using six such ratios achieved strong predictive performance in the test dataset (AUC = 0.807), with a sensitivity of 81.3% and a specificity of 72.7%. Notably, these ratios outperformed conventional tumor markers such as carcinoembryonic antigen and carbohydrate antigen 19-9, in sensitivity. Conclusions: Our results demonstrate that salivary polyamine analysis, particularly using acetylation ratios, enables accurate and minimally invasive detection of GC and represents a promising adjunctive tool for GC screening.
- 22 September 2026
- Published by MDPI AG in Preprints.org
Open AccessSalivary Polyamines Are Effective Biomarkers for Gastric Cancer Detection
Background/Objectives: Gastric cancer (GC) is one of the most prevalent malignancies worldwide, highlighting the need for minimally invasive and highly accurate screening methods for its early detection. We evaluated the utility of salivary polyamine-based metabolomic analysis for distinguishing individuals with GC from those without GC. Methods: A total of 53 patients with GC and 37 non-GC controls were included. Participants were recruited from individuals who underwent upper gastrointestinal endoscopy at Tokyo Medical University Hospital between March 2020 and May 2025 and provided saliva samples on the same day. Participants with factors known to affect polyamine levels were excluded. Salivary metabolites quantified by liquid chromatography–mass spectrometry were statistically compared between groups. Acetylated-to-non-acetylated polyamine ratios were used as features to construct a logistic regression-based machine learning model, and discriminative performance was evaluated using receiver operating characteristic analysis. Results: The GC group showed significantly higher concentrations of salivary metabolites. Among individual polyamines, N1-acetylspermine demonstrated the highest discriminative ability (AUC = 0.845). When acetylated-to-non-acetylated polyamine ratios were analyzed, significant differences between groups were observed for N1,N8-diacetylspermidine/spermidine and N1-acetylspermine/spermine. A logistic regression model constructed using six such ratios achieved strong predictive performance in the test dataset (AUC = 0.807), with a sensitivity of 81.3% and a specificity of 72.7%. Notably, these ratios outperformed conventional tumor markers such as carcinoembryonic antigen and carbohydrate antigen 19-9, in sensitivity. Conclusions: Our results demonstrate that salivary polyamine analysis, particularly using acetylation ratios, enables accurate and minimally invasive detection of GC and represents a promising adjunctive tool for GC screening.
- Open Access
- 29 April 2020
- Published by MDPI AG in Diagnostics
- Vol. 10 (5) , 267
Consistency of Trans-Abdominal and Water-Immersion Ultrasound Images of Diseased Intestinal Segments in Crohn’s Disease
The aim of this study is to clarify whether trans-abdominal ultrasound (TAUS) can reflect actual intestinal conditions in Crohn’s disease (CD) as effectively as water-immersion ultrasound (WIUS) does. This retrospective study enrolled 29 CD patients with 113 intestinal lesions. Five ultrasound (US) parameters (distinct presence/indistinct presence/disappearance of wall stratification in the submucosal and mucosal layers; thickened submucosal layer; irregular mucosal surface; increased fat wrapping around the bowel wall; and fistula signs) that may indicate different states in CD were determined by TAUS and WIUS for the same lesion. Using WIUS as a reference standard, the sensitivity, specificity, and accuracy of TAUS were calculated. The degree of agreement between TAUS and WIUS was evaluated by the kappa coefficient. All US parameters of TAUS had an accuracy >70% (72.6–92.7%). The highest efficacy of TAUS was obtained for fistula signs (sensitivity, specificity, and accuracy values were 63.6%, 96.0%, and 92.7%, respectively). All US parameters between TAUS and WIUS had a definitive (p ≤ 0.001) and moderate-to-substantial consistency (kappa value = 0.446–0.615). The images of TAUS showed substantial similarity to those of WIUS, suggesting that TAUS may function as a substitute to evaluate the actual intestinal conditions of CD.
- 29 April 2020
- Published by MDPI AG in Diagnostics
- Vol. 10 (5) , 267
Open AccessConsistency of Trans-Abdominal and Water-Immersion Ultrasound Images of Diseased Intestinal Segments in Crohn’s Disease
The aim of this study is to clarify whether trans-abdominal ultrasound (TAUS) can reflect actual intestinal conditions in Crohn’s disease (CD) as effectively as water-immersion ultrasound (WIUS) does. This retrospective study enrolled 29 CD patients with 113 intestinal lesions. Five ultrasound (US) parameters (distinct presence/indistinct presence/disappearance of wall stratification in the submucosal and mucosal layers; thickened submucosal layer; irregular mucosal surface; increased fat wrapping around the bowel wall; and fistula signs) that may indicate different states in CD were determined by TAUS and WIUS for the same lesion. Using WIUS as a reference standard, the sensitivity, specificity, and accuracy of TAUS were calculated. The degree of agreement between TAUS and WIUS was evaluated by the kappa coefficient. All US parameters of TAUS had an accuracy >70% (72.6–92.7%). The highest efficacy of TAUS was obtained for fistula signs (sensitivity, specificity, and accuracy values were 63.6%, 96.0%, and 92.7%, respectively). All US parameters between TAUS and WIUS had a definitive (p ≤ 0.001) and moderate-to-substantial consistency (kappa value = 0.446–0.615). The images of TAUS showed substantial similarity to those of WIUS, suggesting that TAUS may function as a substitute to evaluate the actual intestinal conditions of CD.