Atsuhiro Hirayama
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Atsuhiro Hirayama has a total of 23 co-authors. Here are the top co-authors by number of shared publications:
- Akiho Hanzawa
Department of Laboratory Medicine and Clinical Investigation, Yokohama City University Medical Center, Yokohama 232-0024, Japan
1 shared publication - Akira Madarame
Department of Gastroenterology and Hepatology, Tokyo Medical University Hospital, Tokyo, Japan, Japan
1 shared publication - Aya Ikeda
Department of Gastroenterology, Yokohama City University Graduate School of Medicine, 3-9 Fukuura Kanazawa-Ku, Yokohama 236-0004, Japan
1 shared publication - Feiqian Wang
Department of Ultrasound, The First Affiliated Hospital of Xi'an Jiaotong University, Xi'an, Shaanxi, China
1 shared publication - Hideaki Kimura
Inflammatory Bowel Disease Center, Yokohama City University Medical Center, Yokohama, Japan
1 shared publication - Hiromi Yonezawa
Department of Laboratory Medicine and Clinical Investigation, Yokohama City University Medical Center, Yokohama 232-0024, Japan
1 shared publication
Latest Publications
- Open Access
- 29 April 2020
- Published by MDPI AG in Diagnostics
- Vol. 10 (5) , 267
Consistency of Trans-Abdominal and Water-Immersion Ultrasound Images of Diseased Intestinal Segments in Crohn’s Disease
The aim of this study is to clarify whether trans-abdominal ultrasound (TAUS) can reflect actual intestinal conditions in Crohn’s disease (CD) as effectively as water-immersion ultrasound (WIUS) does. This retrospective study enrolled 29 CD patients with 113 intestinal lesions. Five ultrasound (US) parameters (distinct presence/indistinct presence/disappearance of wall stratification in the submucosal and mucosal layers; thickened submucosal layer; irregular mucosal surface; increased fat wrapping around the bowel wall; and fistula signs) that may indicate different states in CD were determined by TAUS and WIUS for the same lesion. Using WIUS as a reference standard, the sensitivity, specificity, and accuracy of TAUS were calculated. The degree of agreement between TAUS and WIUS was evaluated by the kappa coefficient. All US parameters of TAUS had an accuracy >70% (72.6–92.7%). The highest efficacy of TAUS was obtained for fistula signs (sensitivity, specificity, and accuracy values were 63.6%, 96.0%, and 92.7%, respectively). All US parameters between TAUS and WIUS had a definitive (p ≤ 0.001) and moderate-to-substantial consistency (kappa value = 0.446–0.615). The images of TAUS showed substantial similarity to those of WIUS, suggesting that TAUS may function as a substitute to evaluate the actual intestinal conditions of CD.
- 29 April 2020
- Published by MDPI AG in Diagnostics
- Vol. 10 (5) , 267
Open AccessConsistency of Trans-Abdominal and Water-Immersion Ultrasound Images of Diseased Intestinal Segments in Crohn’s Disease
The aim of this study is to clarify whether trans-abdominal ultrasound (TAUS) can reflect actual intestinal conditions in Crohn’s disease (CD) as effectively as water-immersion ultrasound (WIUS) does. This retrospective study enrolled 29 CD patients with 113 intestinal lesions. Five ultrasound (US) parameters (distinct presence/indistinct presence/disappearance of wall stratification in the submucosal and mucosal layers; thickened submucosal layer; irregular mucosal surface; increased fat wrapping around the bowel wall; and fistula signs) that may indicate different states in CD were determined by TAUS and WIUS for the same lesion. Using WIUS as a reference standard, the sensitivity, specificity, and accuracy of TAUS were calculated. The degree of agreement between TAUS and WIUS was evaluated by the kappa coefficient. All US parameters of TAUS had an accuracy >70% (72.6–92.7%). The highest efficacy of TAUS was obtained for fistula signs (sensitivity, specificity, and accuracy values were 63.6%, 96.0%, and 92.7%, respectively). All US parameters between TAUS and WIUS had a definitive (p ≤ 0.001) and moderate-to-substantial consistency (kappa value = 0.446–0.615). The images of TAUS showed substantial similarity to those of WIUS, suggesting that TAUS may function as a substitute to evaluate the actual intestinal conditions of CD.