Xingliang Liu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Xingliang Liu has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- Yan Deng
Zhejiang University
2 shared publications - Guiyun Tian
Chongqing University of Technology
1 shared publication - Haoze Luo
Zhejiang University
1 shared publication - Hefei Jia
College of Electrical Engineering, Zhejiang University, Hangzhou, China
1 shared publication - Jian Zhang
Zhejiang University
1 shared publication Qi Qiu
College of Electrical Engineering, Zhejiang University, Hangzhou, China
1 shared publication
Latest Publications
- 13 December 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 38 (4) , 4760-4770
Nonlinear Resonance Characteristics Analysis of DBD Load Based on State Plane Trajectory
Dielectric barrier discharge (DBD) loads and driving converters are widely utilized in low-temperature plasma generation, but their resonant tanks have typical nonlinear characteristics with control issues. The state plane trajectory analysis is used in this article to investigate the resonant behavior of a DBD load. The converter's working principle and state plane modeling are first discussed. The impact of a high-ratio step-up transformer with parasitic capacitance is then explored, and the updated trajectory model is examined. The DBD platform is created to verify the suggested model, and the associated experimental data are provided. The results of the experiment demonstrate that the discharge trajectory is a zone with distinct borders. The trajectory equations can be utilized to calculate the load equivalent capacitance, and the difference in the boundary equivalent capacitance represents the discharge intensity. The pattern of resonant frequency variation with discharge power is given. The impact mechanism of discharge phenomena and resonance characteristics is discussed.
- 13 December 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 38 (4) , 4760-4770
Nonlinear Resonance Characteristics Analysis of DBD Load Based on State Plane Trajectory
Dielectric barrier discharge (DBD) loads and driving converters are widely utilized in low-temperature plasma generation, but their resonant tanks have typical nonlinear characteristics with control issues. The state plane trajectory analysis is used in this article to investigate the resonant behavior of a DBD load. The converter's working principle and state plane modeling are first discussed. The impact of a high-ratio step-up transformer with parasitic capacitance is then explored, and the updated trajectory model is examined. The DBD platform is created to verify the suggested model, and the associated experimental data are provided. The results of the experiment demonstrate that the discharge trajectory is a zone with distinct borders. The trajectory equations can be utilized to calculate the load equivalent capacitance, and the difference in the boundary equivalent capacitance represents the discharge intensity. The pattern of resonant frequency variation with discharge power is given. The impact mechanism of discharge phenomena and resonance characteristics is discussed.
- Open Access
Non-Contact Degradation Evaluation for IGBT Modules Using Eddy Current Pulsed Thermography Approach
In this paper, a non-contact degradation evaluation method for insulated gate bipolar transistor (IGBT) modules is proposed based on eddy current pulsed thermography approach. In non-contact heat excitation procedures, a high-power induction heater is introduced to generate heat excitation in IGBT modules. The thermographs of the whole temperature mapping are recorded non-invasively by an IR camera. As a result, the joint degradation of IGBT modules can be evaluated by the transient thermal response curves derived from the recorded thermographs. Firstly, the non-destructive evaluation principle of the eddy current pulsed thermography (ECPT) system for an IGBT module with a heat sink is introduced. A 3D simulation module is built with physical parameters in ANSYS simulations, and then thermal propagation behavior considering the degradation impact is investigated. An experimental ECPT system is set up to verify the effectiveness of the proposed method. The experimental results show that the delay time to peak temperature can be extracted and treated as an effective indicative feature of joint degradation.
Open AccessNon-Contact Degradation Evaluation for IGBT Modules Using Eddy Current Pulsed Thermography Approach
In this paper, a non-contact degradation evaluation method for insulated gate bipolar transistor (IGBT) modules is proposed based on eddy current pulsed thermography approach. In non-contact heat excitation procedures, a high-power induction heater is introduced to generate heat excitation in IGBT modules. The thermographs of the whole temperature mapping are recorded non-invasively by an IR camera. As a result, the joint degradation of IGBT modules can be evaluated by the transient thermal response curves derived from the recorded thermographs. Firstly, the non-destructive evaluation principle of the eddy current pulsed thermography (ECPT) system for an IGBT module with a heat sink is introduced. A 3D simulation module is built with physical parameters in ANSYS simulations, and then thermal propagation behavior considering the degradation impact is investigated. An experimental ECPT system is set up to verify the effectiveness of the proposed method. The experimental results show that the delay time to peak temperature can be extracted and treated as an effective indicative feature of joint degradation.
- Open Access
- 10 April 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 8, 73746-73755
Analytical Estimation Method of Winding Parasitic Capacitance for High-Frequency High-Voltage Application
Aiming to calculate the winding parasitic capacitance for high-frequency high-voltage application, this paper proposes an improved energy method by dividing the electrostatic field into several energy regions. Analytical models of the divided energy regions are established based on the assumed electric field distribution. The stored electrostatic energy in the specified regions covers not only the energy between adjacent turns but also the non-adjacent turns, and a compensation factor is introduced to correct the layer misalignment problem of the standard winding, which makes the analytical energy fairly accurate. Following closely, a calculation procedure of parasitic capacitance is demonstrated. In the end, the accuracy and effectiveness of this method are verified by finite element simulations and measurements.
- 10 April 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 8, 73746-73755
Open AccessAnalytical Estimation Method of Winding Parasitic Capacitance for High-Frequency High-Voltage Application
Aiming to calculate the winding parasitic capacitance for high-frequency high-voltage application, this paper proposes an improved energy method by dividing the electrostatic field into several energy regions. Analytical models of the divided energy regions are established based on the assumed electric field distribution. The stored electrostatic energy in the specified regions covers not only the energy between adjacent turns but also the non-adjacent turns, and a compensation factor is introduced to correct the layer misalignment problem of the standard winding, which makes the analytical energy fairly accurate. Following closely, a calculation procedure of parasitic capacitance is demonstrated. In the end, the accuracy and effectiveness of this method are verified by finite element simulations and measurements.