RARehman Ali

Rehman Ali

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Rehman Ali has a total of 41 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    3D Frequency-Domain Full Waveform Inversion for Whole-Breast Imaging With a Multi-Row Ring Array

    by Rehman Ali, Gaofei Jin, Melanie Singh, Trevor Mitcham, Nebojsa Duric

    For ring-array ultrasound tomography, two-dimensional frequency-domain full waveform inversion is the clinical gold standard for high-resolution imaging of the breast. While yielding high-resolution images in the plane of the ring-array, the resulting slice-wise approach yields lower resolution out of plane when used to reconstruct the full volume. Instead, this work proposes a fully three-dimensional full-waveform inversion based on a multi-row ring-array transducer to improve out-of-plane resolution, while using cylindrical-wave transmissions to minimize acquisition and reconstruction time. For each numerical breast phantom tested, the root-mean-square error of three-dimensional full-waveform inversion is less than that of two-dimensional slice-wise full-waveform inversion by 6.3-13.7 m/s.


  • Open Access

    Frequency-differencing strategy to kickstart full-waveform inversion without cycle skipping

    by Rehman Ali, Trevor Mitcham, Israel Owolabi, Sarah McConnell, Nebojsa Duric

    Ultrasound tomography fundamentally relies on low-frequency data to avoid cycle skipping in full-waveform inversion (FWI). In the absence of sufficiently low-frequency data, we can extrapolate low-frequency content from existing high-frequency signals by using the same approach used in frequency-difference beamforming. This low-frequency content is then used to kickstart FWI and avoid cycle skipping at higher frequencies. In simulations, the structural similarity index measure and peak signal-to-noise ratio of the reconstructed image improve by 0.28 and 8.6 dB, respectively, as a result of frequency differencing. Experiments show that internal structures can be seen with greater clarity because of frequency differencing.


  • Open Access

    Generating and monitoring mild hyperthermia using a ring array ultrasound transducer

    by David Bustamante, Yan Yan, Trevor Mitcham, Rehman Ali, Brian Marples, Kimberly R. Gergelis, Peter Littrup, Nebojsa Duric, Mohammad Mehrmohammadi

    To demonstrate the feasibility of using a ring array ultrasound (US) transducer, guided by ultrasound tomography (UST), for generating and monitoring mild hyperthermia (MHTh). In silico and in vitro experiments were designed to evaluate the efficacy of a ring array US transducer for generating MHTh and monitoring changes in temperature. In a series of in silico studies, we compared the acoustic focal profiles produced by a ring array US transducer transmitting at different frequencies and further investigated the effectiveness of UST-guidance in implementing aberration correction to enhance the focal profile. In vitro experiments evaluated the capability of using a ring array US transducer to generate and maintain MHTh and the accuracy of using UST to monitor temperature changes. The simulations demonstrated that a ring array US transducer achieves symmetrical and localized acoustic focusing. In a heterogenous tissue model, a ring array US transducer achieved a superior acoustic focus by implementing aberration correction with guidance from UST. In vitro experiments demonstrated the capability of a ring array US transducer to generate MHTh in a tissue-mimicking phantom in an average of 117 ± 18 s and subsequently maintain MHTh. Lastly, a ring array US transducer utilized UST to track temperature changes in a preheated water-filled inclusion while it passively cooled from 45 °C to 25 °C, with a maximum error of 0.58 °C. A ring array US transducer can noninvasively generate and monitor MHTh, overcoming many limitations of current clinical systems. The closed geometry of the transducer is optimal for acoustic focusing and UST-guidance allows for improved aberration correction in a heterogenous medium. Utilizing UST thermometry with the same ring array US transducer will allow for implementing an image-guided, temperature-controlled, all-acoustic MHTh system.


  • 2-D Slicewise Waveform Inversion of Sound Speed and Acoustic Attenuation for Ring Array Ultrasound Tomography Based on a Block LU Solver

    by Rehman Ali, Trevor M. Mitcham, Thurston Brevett, Òscar Calderón Agudo, Cristina Durán Martinez, Cuiping Li, Marvin M. Doyley, Nebojsa Duric

    Ultrasound tomography is an emerging imaging modality that uses the transmission of ultrasound through tissue to reconstruct images of its mechanical properties. Initially, ray-based methods were used to reconstruct these images, but their inability to account for diffraction often resulted in poor resolution. Waveform inversion overcame this limitation, providing high-resolution images of the tissue. Most clinical implementations, often directed at breast cancer imaging, currently rely on a frequency-domain waveform inversion to reduce computation time. For ring arrays, ray tomography was long considered a necessary step prior to waveform inversion in order to avoid cycle skipping. However, in this paper, we demonstrate that frequency-domain waveform inversion can reliably reconstruct high-resolution images of sound speed and attenuation without relying on ray tomography to provide an initial model. We provide a detailed description of our frequency-domain waveform inversion algorithm with open-source code and data that we make publicly available.


  • Sound Speed Estimation for Distributed Aberration Correction in Laterally Varying Media

    by Rehman Ali, Trevor M. Mitcham, Melanie Singh, Marvin M. Doyley, Richard R. Bouchard, Jeremy J. Dahl, Nebojsa Duric

    Spatial variation in sound speed causes aberration in medical ultrasound imaging. Although our previous work has examined aberration correction in the presence of a spatially varying sound speed, practical implementations were limited to layered media due to the sound speed estimation process involved. Unfortunately, most models of layered media do not capture the lateral variations in sound speed that have the greatest aberrative effect on the image. Building upon a Fourier split-step migration technique from geophysics, this work introduces an iterative sound speed estimation and distributed aberration correction technique that can model and correct for aberrations resulting from laterally varying media. We first characterize our approach in simulations where the scattering in the media is known a-priori. Phantom and in-vivo experiments further demonstrate the capabilities of the iterative correction technique. As a result of the iterative correction scheme, point target resolution improves by up to a factor of 4 and lesion contrast improves by up to 10.0 dB in the phantom experiments presented.


  • Separation of mainlobe and sidelobe contributions to B-mode ultrasound images based on the aperture spectrum

    by Rehman Ali, Trevor Mitcham, Leandra Brickson, Wentao Hu, Marvin Doyley, Deborah Rubens, Zeljko Ignjatovic, Nebojsa Duric, Jeremy Dahl

    PurposeIsolating the mainlobe and sidelobe contribution to the ultrasound image can improve imaging contrast by removing off-axis clutter. Previous work achieves this separation of mainlobe and sidelobe contributions based on the covariance of received signals. However, the formation of a covariance matrix at each imaging point can be computationally burdensome and memory intensive for real-time applications. Our work demonstrates that the mainlobe and sidelobe contributions to the ultrasound image can be isolated based on the receive aperture spectrum, greatly reducing computational and memory requirements.ApproachThe separation of mainlobe and sidelobe contributions to the ultrasound image is shown in simulation, in vitro, and in vivo using the aperture spectrum method and multicovariate imaging of subresolution targets (MIST). Contrast, contrast-to-noise-ratio (CNR), and speckle signal-to-noise-ratio are used to compare the aperture spectrum approach with MIST and conventional delay-and-sum (DAS) beamforming.ResultsThe aperture spectrum approach improves contrast by 1.9 to 6.4 dB beyond MIST and 8.9 to 13.5 dB beyond conventional DAS B-mode imaging. However, the aperture spectrum approach yields speckle texture similar to DAS. As a result, the aperture spectrum-based approach has less CNR than MIST but greater CNR than conventional DAS. The CPU implementation of the aperture spectrum-based approach is shown to reduce computation time by a factor of 9 and memory consumption by a factor of 128 for a 128-element transducer.ConclusionsThe mainlobe contribution to the ultrasound image can be isolated based on the receive aperture spectrum, which greatly reduces the computational cost and memory requirement of this approach as compared with MIST.


  • Distributed Aberration Correction Techniques Based on Tomographic Sound Speed Estimates

    by Rehman Ali, Thurston Brevett, Dongwoon Hyun, Leandra L. Brickson, Jeremy J. Dahl

    Phase aberration is widely considered a major source of image degradation in medical pulse-echo ultrasound. Traditionally, near-field phase aberration correction techniques are unable to account for distributed aberrations due to a spatially varying speed of sound in the medium, while most distributed aberration correction techniques require the use of point-like sources and are impractical for clinical applications where diffuse scattering is dominant. Here, we present two distributed aberration correction techniques that utilize sound speed estimates from a tomographic sound speed estimator that builds on our previous work with diffuse scattering in layered media. We first characterize the performance of our sound speed estimator and distributed aberration correction techniques in simulations where the scattering in the media is known a priori . Phantom and in vivo experiments further demonstrate the capabilities of the sound speed estimator and the aberration correction techniques. In phantom experiments, point target resolution improves from 0.58 to 0.26 and 0.27 mm, and lesion contrast improves from 17.7 to 23.5 and 25.9 dB, as a result of distributed aberration correction using the eikonal and wavefield correlation techniques, respectively.


  • Open Access

    Local Sound Speed Estimation for Pulse-Echo Ultrasound in Layered Media

    by Rehman Ali, Arsenii V. Telichko, Huaijun Wang, Uday K. Sukumar, Jose G. Vilches-Moure, Ramasamy Paulmurugan, Jeremy J. Dahl

    Our previous methodology in local sound speed estimation utilized time delays measured by the cross correlation of delayed full-synthetic aperture channel data to estimate the average speed of sound. However, focal distortions in this methodology lead to biased estimates of the average speed of sound, which, in turn, leads to biased estimates of the local speed of sound. Here, we demonstrate the bias in the previous methodology and introduce a coherence-based average sound speed estimator that eliminates this bias and is computationally much cheaper in practice. Because this coherence-based approach estimates the average sound speed in the medium over an equally spaced grid in depth rather than time, we derive a refined model that relates the local and average speeds of sound as a function of depth in layered media. A fast, closed-form inversion of this model yields highly accurate local sound speed estimates. The root-mean-square (rms) error of local sound speed reconstruction in simulations of two-layer media is 4.6 and 2.5 m/s at 4 and 8 MHz, respectively. This work examines the impact of frequency, ${f}$ -number, aberration, and reverberation on sound speed estimation. Phantom and in vivo experiments in rats further validate the coherence-based sound speed estimator.


  • Noninvasive estimation of local speed of sound by pulse-echo ultrasound in a rat model of nonalcoholic fatty liver

    by Arsenii V Telichko, Rehman Ali, Thurston Brevett, Huaijun Wang, Jose G Vilches-Moure, Sukumar U Kumar, Ramasamy Paulmurugan, Jeremy J Dahl

    Objective. Speed of sound has previously been demonstrated to correlate with fat concentration in the liver. However, estimating speed of sound in the liver noninvasively can be biased by the speed of sound of the tissue layers overlying the liver. Here, we demonstrate a noninvasive local speed of sound estimator, which is based on a layered media assumption, that can accurately capture the speed of sound in the liver. We validate the estimator using an obese Zucker rat model of non-alcoholic fatty liver disease and correlate the local speed of sound with liver steatosis. Approach. We estimated the local and global average speed of sound noninvasively in 4 lean Zucker rats fed a normal diet and 16 obese Zucker rats fed a high fat diet for up to 8 weeks. The ground truth speed of sound and fat concentration were measured from the excised liver using established techniques. Main Results. The noninvasive, local speed of sound estimates of the livers were similar in value to their corresponding ‘ground truth’ measurements, having a slope ± standard error of the regression of 0.82 ± 0.15 (R 2 = 0.74 and p < 0.001). Measurement of the noninvasive global average speed of sound did not reliably capture the ‘ground truth’ speed of sound in the liver, having a slope of 0.35 ± 0.07 (R 2 = 0.74 and p < 0.001). Decreasing local speed of sound was observed with increasing hepatic fat accumulation (approximately −1.7 m s−1 per 1% increase in hepatic fat) and histopathology steatosis grading (approximately −10 to −13 m s−1 per unit increase in steatosis grade). Local speed of sound estimates were highly correlated with steatosis grade, having Pearson and Spearman correlation coefficients both ranging from −0.87 to −0.78. In addition, a lobe-dependent speed of sound in the liver was observed by the ex vivo measurements, with speed of sound differences of up to 25 m s−1 (p < 0.003) observed between lobes in the liver of the same animal. Significance. The findings of this study suggest that local speed of sound estimation has the potential to be used to predict or assist in the measurement of hepatic fat concentration and that the global average speed of sound should be avoided in hepatic fat estimation due to significant bias in the speed of sound estimate.