Latest Publications

  • Real-Time Reverberation Suppression in Ultrasound Channel Signals Using a Permuted 2D Convolutional Neural Network

    by Leandra L. Brickson, Dongwoon Hyun, Hoda S. Hashemi, Walter A. Simson, Neha Antil, Gianmarco Pinton, Jeremy J. Dahl

    Diffuse reverberation noise in ultrasound imaging arises from multiple reflections or secondary scattering of an echo, such as when a strong echo reflects multiple times between a fascial layer and the transducer. Unlike coherent reverberation artifacts, such as multiple reflections within an arterial wall that produce obvious ringdown in the image, these multiple reflections produce speckle-like artifacts that overlay and obscure anatomical targets and are difficult to distinguish from tissue speckle. This noise also degrades image reconstruction and interferes with imaging techniques that rely on displacement or time shifts in the ultrasonic echoes. This work introduces a permuted 2D convolutional neural network (2DCNN) for real-time reverberation suppression in ultrasound channel signals. This technique can be used to improve B-mode image quality or can be used as a pre-processing filter for techniques that require channel or beamsummed signals. The proposed architecture offers significant computational advantages over the previously implementations using 3D convolutional networks, enabling real-time implementation on existing hardware at 15 fps. The 2DCNN was trained on an enhanced dataset that combines Field II and Fullwave simulations, incorporating a broad range of acoustic affects, including reverberation noise, aberration, and attenuation. Validation on liver and kidney scans from 15 volunteers demonstrated improvements in image quality metrics related to the removal of diffuse reverberation noise, including increasing contrast, generalized contrast-to-noise ratio (GCNR), and lag-one coherence (LOC).

  • Open Access

    Elephants and algorithms: a review of the current and future role of AI in elephant monitoring

    by Leandra Brickson, Libby Zhang, Fritz Vollrath, Iain Douglas-Hamilton, Alexander J. Titus

    Artificial intelligence (AI) and machine learning (ML) present revolutionary opportunities to enhance our understanding of animal behaviour and conservation strategies. Using elephants, a crucial species in Africa and Asia’s protected areas, as our focal point, we delve into the role of AI and ML in their conservation. Given the increasing amounts of data gathered from a variety of sensors like cameras, microphones, geophones, drones and satellites, the challenge lies in managing and interpreting this vast data. New AI and ML techniques offer solutions to streamline this process, helping us extract vital information that might otherwise be overlooked. This paper focuses on the different AI-driven monitoring methods and their potential for improving elephant conservation. Collaborative efforts between AI experts and ecological researchers are essential in leveraging these innovative technologies for enhanced wildlife conservation, setting a precedent for numerous other species.


  • Separation of mainlobe and sidelobe contributions to B-mode ultrasound images based on the aperture spectrum

    by Rehman Ali, Trevor Mitcham, Leandra Brickson, Wentao Hu, Marvin Doyley, Deborah Rubens, Zeljko Ignjatovic, Nebojsa Duric, Jeremy Dahl

    PurposeIsolating the mainlobe and sidelobe contribution to the ultrasound image can improve imaging contrast by removing off-axis clutter. Previous work achieves this separation of mainlobe and sidelobe contributions based on the covariance of received signals. However, the formation of a covariance matrix at each imaging point can be computationally burdensome and memory intensive for real-time applications. Our work demonstrates that the mainlobe and sidelobe contributions to the ultrasound image can be isolated based on the receive aperture spectrum, greatly reducing computational and memory requirements.ApproachThe separation of mainlobe and sidelobe contributions to the ultrasound image is shown in simulation, in vitro, and in vivo using the aperture spectrum method and multicovariate imaging of subresolution targets (MIST). Contrast, contrast-to-noise-ratio (CNR), and speckle signal-to-noise-ratio are used to compare the aperture spectrum approach with MIST and conventional delay-and-sum (DAS) beamforming.ResultsThe aperture spectrum approach improves contrast by 1.9 to 6.4 dB beyond MIST and 8.9 to 13.5 dB beyond conventional DAS B-mode imaging. However, the aperture spectrum approach yields speckle texture similar to DAS. As a result, the aperture spectrum-based approach has less CNR than MIST but greater CNR than conventional DAS. The CPU implementation of the aperture spectrum-based approach is shown to reduce computation time by a factor of 9 and memory consumption by a factor of 128 for a 128-element transducer.ConclusionsThe mainlobe contribution to the ultrasound image can be isolated based on the receive aperture spectrum, which greatly reduces the computational cost and memory requirement of this approach as compared with MIST.


  • Distributed Aberration Correction Techniques Based on Tomographic Sound Speed Estimates

    by Rehman Ali, Thurston Brevett, Dongwoon Hyun, Leandra L. Brickson, Jeremy J. Dahl

    Phase aberration is widely considered a major source of image degradation in medical pulse-echo ultrasound. Traditionally, near-field phase aberration correction techniques are unable to account for distributed aberrations due to a spatially varying speed of sound in the medium, while most distributed aberration correction techniques require the use of point-like sources and are impractical for clinical applications where diffuse scattering is dominant. Here, we present two distributed aberration correction techniques that utilize sound speed estimates from a tomographic sound speed estimator that builds on our previous work with diffuse scattering in layered media. We first characterize the performance of our sound speed estimator and distributed aberration correction techniques in simulations where the scattering in the media is known a priori . Phantom and in vivo experiments further demonstrate the capabilities of the sound speed estimator and the aberration correction techniques. In phantom experiments, point target resolution improves from 0.58 to 0.26 and 0.27 mm, and lesion contrast improves from 17.7 to 23.5 and 25.9 dB, as a result of distributed aberration correction using the eikonal and wavefield correlation techniques, respectively.


  • Reverberation Noise Suppression in Ultrasound Channel Signals Using a 3D Fully Convolutional Neural Network

    by Leandra L. Brickson, Dongwoon Hyun, Marko Jakovljevic, Jeremy J. Dahl

    Diffuse reverberation is ultrasound image noise caused by multiple reflections of the transmitted pulse before returning to the transducer, which degrades image quality and impedes the estimation of displacement or flow in techniques such as elastography and Doppler imaging. Diffuse reverberation appears as spatially incoherent noise in the channel signals, where it also degrades the performance of adaptive beamforming methods, sound speed estimation, and methods that require measurements from channel signals. In this paper, we propose a custom 3D fully convolutional neural network (3DCNN) to reduce diffuse reverberation noise in the channel signals. The 3DCNN was trained with channel signals from simulations of random targets that include models of reverberation and thermal noise. It was then evaluated both on phantom and in-vivo experimental data. The 3DCNN showed improvements in image quality metrics such as generalized contrast to noise ratio (GCNR), lag one coherence (LOC) contrast-to-noise ratio (CNR) and contrast for anechoic regions in both phantom and in-vivo experiments. Visually, the contrast of anechoic regions was greatly improved. The CNR was improved in some cases, however the 3DCNN appears to strongly remove uncorrelated and low amplitude signal. In images of in-vivo carotid artery and thyroid, the 3DCNN was compared to short-lag spatial coherence (SLSC) imaging and spatial prediction filtering (FXPF) and demonstrated improved contrast, GCNR, and LOC, while FXPF only improved contrast and SLSC only improved CNR.