BPBertalan Pizág

Bertalan Pizág

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Bertalan Pizág has a total of 7 co-authors. Here are the top co-authors by number of shared publications:

  • Ágnes Urbin

    Budapest University of Technology and Economics , Faculty of Mechanical Engineering, Department of Mechatronics, Optics and Mechanical Engineering Informatics , Budapest , Hungary

    2 shared publications
  • Balázs Vince Nagy

    Budapest Univ Technol & Econ, Dept Mechatron Opt & Mech Engn Informat, 4-6 Bertalan Lajos St, H-1111 Budapest, Hungary

    1 shared publication
  • Balázs Vince Nagy

    Department of Mechatronics, Optics and Engineering Informatics, Faculty of Mechanical Engineering Budapest University of Technology and Economics Budapest Hungary

    1 shared publication
  • Csaba Budai

    Department of Mechatronics, Optics and Mechanical Engineering Informatics, Faculty of Mechanical Engineering, Budapest University of Technology and Economics, Budapest, Hungary

    1 shared publication
  • Erika Rácz

    1 shared publication
  • Gyöngyvér Tóthpálné Hidegh

    1 shared publication

Latest Publications

  • HYPERSPECTRAL IMAGING IN AGRICULTURE – EVALUATING THE SPECTRAL DEPENDENCY OF VEGETATION INDICES

    by Bertalan Pizág, Ágnes Urbin, Csaba Budai, Balázs Vince Nagy

    Vegetation indices have been in active use for over five decades. They are remote sensing indicators derived from surface reflectance data to highlight various vegetation-related properties. Their popularity stems partly from their simplicity. Each index is computed by simple formulas using the pixel values of a handful of multispectral bands. However, the loose definition of spectral bands introduces a device-specific discrepancy to the results as the spectral sensitivity can vary significantly between different systems and slightly even between different units of the same model. This paper uses hyperspectral aerial images to investigate the cross-instrument differences of some popular vegetation indices. The spectral characteristics of various multispectral instruments are reconstructed from the much narrower hyperspectral bands, creating the device-specific projections of the dataset. The differences between devices are presented using these transformed values.

  • Open Access

    Flame emission spectroscopy analysis of distributed liquid fuel combustion

    by Gyöngyvér Tóthpálné Hidegh, Bertalan Pizág, Ágnes Urbin, Erika Rácz, Viktor Józsa


  • Propagation of positioning uncertainties in near-field goniophotometers using the Monte Carlo method

    by Bertalan Pizág, Balázs Vince Nagy

    The method of near-field goniophotometry is used ever-increasingly to acquire detailed luminance information about various luminaires. It overcomes certain limitations of its predecessor, the widely used and thoroughly standardized far-field goniophotometry, and provides further opportunities to expand the scope of the measurement, but also introduces a new set of limiting factors. The aim of this paper is to examine the effect of positioning uncertainties on near-field goniophotometric measurements’ results. For this, a simplified ray tracing model is constructed computable in closed form as stacked matrix equations, in order to reduce the computation time as much as possible. The model is then fed to a simulated goniophotometric measurement, loaded with various uncertainties according to the Monte Carlo method. Finally, the resulting uncertainties are derived from statistical analysis of the output in both the near and far fields. Various metrics are tested as potential criteria for acceptance, including correlation and repeated measures ANOVA tests, both faring well until the angle of incidence of the rays is below 55°, the ANOVA test being more sensitive to sampling and rejecting systems with 0.1° angular error and above, while the same results still pass the correlation test until 0.5°. Converted far-field results are compared to the standardized requirements, indicating the necessity of similar mechanical precision.