Narender Kumar has a total of 78 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Invasiveness Study of Supersonic Gas-Curtain-Based Ionization Profile Monitor for Medical Accelerators

    by William Butcher, Narender Kumar, Milaan Patel, Bharat Singh Rawat, Oliver Stringer, Farhana Thesni Mada Parambil, Hao Zhang, Carsten P. Welsch

    In proton beam therapy, ideally, beam monitoring should be non-invasive to provide online real-time feedback, such that the total dose delivered to the patient is not significantly affected. The invasiveness of the Supersonic Gas-Curtain-Based Ionization Profile Monitor (SGC-IPM) system was quantified by perturbation in beam current and transverse beam profile parameters induced by the supersonic gas-curtain for a 4.9–5.3 keV electron beam, representing a worst-case scenario where perturbations can be more easily observable. The experimentally measured gas-curtain effects on transverse beam parameters (≤2%), intensity (≤−1%) and beam current (≤−1%) were small in magnitude and largely below resolution limits. To confirm these effects, order-of-magnitude beam–gas interaction approximations were calculated for the experimental energy range, demonstrating negligible energy loss with minor scattering, broadly consistent with the experimental results. Clinical proton beam gas-curtain predictions (70–250 MeV) indicate a further reduction of ∼104 compared to the experimental observations. Even under the conservative electron beam conditions used in this study, the observed perturbations were minor or unresolvable and measured effects were significantly smaller than spatial and dosimetry scales relevant to proton radiotherapy. Overall, the experimental measurements and supporting order-of-magnitude estimates demonstrate that the SGC-IPM introduces negligible perturbations to beam parameters and is predicted to provide non-invasive beam profile monitoring for clinical proton beam diagnostics.

  • Open Access

    Radiation environment at FCC-ee experimental insertion regions

    by Alessandro Frasca, Manuela Boscolo, Giacomo Broggi, Roderik Bruce, Francesco Cerutti, Andrea Ciarma, Barbara Humann, Narender Kumar, Anton Lechner, Giuseppe Lerner, et al.

    The future circular electron-positron collider will provide collisions at four interaction points (IPs) along a 91-km ring, with beam energies ranging from 45.6 GeV (Z pole) to 182.5 GeV ( t t ¯ threshold). Several processes, induced by both the collisions at the IPs and the circulating beams, contribute to the radiation environment of the experimental insertion regions, exposing the detector, machine equipment, and electronics. Quantifying these radiation fields and their effects is essential to guide design strategies. In this work, the Monte Carlo code is employed to simulate the propagation of radiation showers from both IP-driven and beam-driven sources, including radiative Bhabha scattering, incoherent pair creation, beamstrahlung, synchrotron radiation, and beam-gas interactions. Power deposition, equivalent fluences, and total ionizing dose are estimated to assess the exposure of sensitive components and to characterize tunnel radiation levels at the Z-pole and t t ¯ -threshold modes. The results show that incoherent pairs dominate the detector environment, particularly in the tracker, while radiative Bhabha losses in the superconducting final-focus quadrupoles (FFQs) require shielding to ensure safe magnet operation. Tunnel radiation levels exceed the tolerance of standard equipment at both operational modes, being dominated by radiative Bhabha and collimation losses at the Z pole, and by synchrotron radiation at the t t ¯ threshold. While a tungsten layer is shown to effectively protect the FFQs, the high radiation levels elsewhere indicate the need for additional shielding in dipoles and drifts, as well as dedicated absorbers downstream of the IPs and collimators.

  • Open Access

    Characterization of the Extraction System of Supersonic Gas Curtain-Based Ionization Profile Monitor for FLASH Proton Therapy

    by Farhana Thesni Mada Parambil, Milaan Patel, Narender Kumar, Bharat Singh Rawat, William Butcher, Tony Price, Carsten P. Welsch

    FLASH radiotherapy requires real-time, non-invasive beam monitoring systems capable of operating under ultra-high dose rate (UHDR) conditions without perturbing the therapeutic beam. In this work, we characterized the extraction system of Supersonic Gas Curtain-based Ionization Profile Monitor (SGC-IPM) for its capabilities as a transverse beam profile and position monitor for FLASH protons. The monitor utilizes a tilted gas curtain intersected by the incident beam, leading to the generation of ions that are extracted through a tailored electrostatic field, and detected using a two stage microchannel plate (MCP) coupled to a phosphor screen and CMOS camera. CST Studio Suite was employed to conduct electrostatic and particle tracking simulations evaluating the ability of the extraction system to measure both beam profile and position. The ion interface, at the interaction region of proton beam and gas curtain, was modeled with realistic proton beam parameters and uniform gas curtain density distributions. The ion trajectory was tracked to evaluate the performance across multiple beam sizes. The simulations suggest that the extraction system can reconstruct transverse beam profiles for different proton beam sizes. Simulations also supported the system’s capability as a beam position monitor within the boundary defined by the beam size, the dimensions of the extraction system, and the height of the gas curtain. Some simulation results were benchmarked against experimental data of 28 MeV proton beam with 70 nA average beam current. This study will further help to optimize the design of the extraction system to facilitate the integration of SGC-IPM in medical accelerators.

  • Open Access

    Supersonic gas curtain based ionization beam profile monitor for FLASH proton beam therapy

    by Milaan Patel, Narender Kumar, Farhana Thesni, William Butcher, Tony Price, Ruth McLauchlan, Carsten P. Welsch

    Introduction: FLASH Proton Beam Therapy (FLASH-PBT) combines the precision targeting ability of proton beam with radiobiological advantage of FLASH effect at ultra-high dose rates ( > 40 Gy/s) to improve tumor control while reducing the damage to surrounding healthy tissues. The commonly used spot-scanning proton therapy technique relies on real-time beam monitoring to provide feedback to the accelerator for spot switching. This study introduces a novel Supersonic Gas Curtain Ionization Profile Monitor (SGC-IPM) for non-invasive, high-resolution proton beam profile monitoring, aiming to provide real-time feedback to medical accelerators. Methods: The SGC-IPM uses a supersonic gas jet shaped into a curtain to measure the 2D transverse profile of the beam. Initial tests of the device was conducted on a DC Pelletron accelerator at Dalton Cumbrian Facility (DCF), Whitehaven, UK, followed by later tests on MC40 cyclotron at the University of Birmingham (UoB), UK. Across both the experiments, the device was directly coupled to the vacuum side of the beamlines and beam profiles were recorded for protons at energies ranging from 4–28 MeV and currents ranging from 1–100 nA, with various beam sizes and shapes. Results: The SGC-IPM successfully measured beam profiles and demonstrated a linear response to beam currents across the measurement range, and its response at different energies was quantified by introducing an energy-dependent detection factor, D which is used to quantify the sensitivity of the device. The detector was upgraded after the first set of experiments at DCF resulting in sensitivity improvement by a factor of 80 in later experiments at UoB. Discussions: A mathematical model is introduced to show that device’s response depends on particle fluence, a quantity independent of dose rate. It’s linear response to beam current is used to extrapolate measurements at conventional dose rates to assess its performance at FLASH dose rates. The performance is evaluated in terms of threshold dose required to measure beam profile for a standard 1-liter clinical volume positioned 15–20 cm deep in water. Conclusion: This study presents a viable solution for non-invasive proton beam profile monitoring for FLASH-PBT. The device shows a linear response to beam current within the measurement range. The mathematical model quantifies the device’s sensitivity and provides a means to calibrate it for dose estimation.


  • Open Access

    Faraday Cups: Principles, Designs, and Applications Across Scientific Disciplines—A Review

    by Bharat Singh Rawat, Narender Kumar, Debdeep Ghosal, Daliya Aflyatunova, Benjamin Rienäcker, Carsten. P. Welsch

    Beam diagnostics are essential tools for monitoring the performance of charged particle beams and the safe operation of particle accelerators. The performance of an accelerator is determined by evaluating the properties of beam particles, such as energy, charge, spatial, and temporal density distributions, which require very specific instruments. Faraday Cups (FCs) have emerged as important beam diagnostic devices because of their ability to accurately measure the beam charge and, in some cases, the charge distribution, which can be subsequently used to reconstruct transverse beam profiles. This paper aims to provide a detailed review of FCs, their principles, and their design challenges. FCs have applications in various scientific disciplines that include the measurement of beam current/intensity in particle accelerators, in addition to those for mass spectrometry, beam profiles/total beam currents for broad ion beams, thermonuclear fusion, and antimatter experiments. This review also covers and discusses the versatility of FCs in various scientific disciplines, along with showcasing the technological advancements that include improved collector materials, novel designs, enhanced measurement techniques, and developments in electronics and data acquisition (D.A.Q). A summary of the challenges faced while working with the FCs, such as sensitivity, calibration, and potential errors, is included in this review.


  • Open Access

    Cherenkov Radiation in Optical Fibres as a Versatile Machine Protection System in Particle Accelerators

    by Joseph Wolfenden, Alexandra S. Alexandrova, Frank Jackson, Storm Mathisen, Geoffrey Morris, Thomas H. Pacey, Narender Kumar, Monika Yadav, Angus Jones, Carsten P. Welsch

    Machine protection systems in high power particle accelerators are crucial. They can detect, prevent, and respond to events which would otherwise cause damage and significant downtime to accelerator infrastructure. Current systems are often resource heavy and operationally expensive, reacting after an event has begun to cause damage; this leads to facilities only covering certain operational modes and setting lower limits on machine performance. Presented here is a new type of machine protection system based upon optical fibres, which would be complementary to existing systems, elevating existing performance. These fibres are laid along an accelerator beam line in lengths of ∼100 m, providing continuous coverage over this distance. When relativistic particles pass through these fibres, they generate Cherenkov radiation in the optical spectrum. This radiation propagates in both directions along the fibre and can be detected at both ends. A calibration based technique allows the location of the Cherenkov radiation source to be pinpointed to within 0.5 m with a resolution of 1 m. This measurement mechanism, from a single device, has multiple applications within an accelerator facility. These include beam loss location monitoring, RF breakdown prediction, and quench prevention. Detailed here are the application processes and results from measurements, which provide proof of concept for this device for both beam loss monitoring and RF breakdown detection. Furthermore, highlighted are the current challenges for future innovation.


  • Defect engineered blue photoluminescence in ZnO:Al/TiO2 heterostructures

    by C. P. Saini, S. Bhowmick, A. Barman, N. Kumar, A. Das, S. A. Khan, A. Claverie, D. Kanjilal, R. N. Mahato, K. Singh, et al.

    Tailoring the blue photoluminescence (PL) in Al-doped ZnO (AZO)/TiO2 heterostructures is demonstrated by a controlled induction of shallow defect centers by 50 keV Ar+-ions. This is established by a combination of temperature dependent PL and electron paramagnetic resonance spectroscopy. The dominant blue-violet PL in an as-grown sample comprises a near band-edge emission, along with a peak associated with a radiative recombination of the electrons in shallow donor levels (Zn interstitials) and the holes from the valence band. However, the evolution of an additional yellow-green PL band at a fluence of 1 × 1015 ions/cm2 is governed by deep donor levels, particularly ionized oxygen vacancies. Irradiation at 1 × 1016 ions/cm2 further leads to the formation of Zn vacancies (shallow acceptors) owing to the development of an O-rich surface. The structural modifications of these samples have been investigated by field-emission scanning electron microscopy , transmission electron microscopy, and Rutherford backscattering. While small micro-cracks are found at a fluence of 2 × 1016 ions/cm2, the formation of graded layers is obtained at the highest fluence of 5 × 1016 ions/cm2 owing to ballistic intermixing and diffusion of the constituents. Detailed investigation suggests that a significant amount of Ti atoms is diffused in AZO by a complete deterioration of the AZO/TiO2 matrix at the highest fluence.


  • Design and development of a compact ion implanter and plasma diagnosis facility based on a 2.45 GHz microwave ion source

    by Ram Swaroop, Narender Kumar, G. Rodrigues, D. Kanjilal, I. Banerjee, S. K. Mahapatra

    A project on developing a 2.45 GHz microwave ion source based compact ion implanter and plasma diagnostic facility has been taken up by the Central University of Punjab, Bathinda. It consists of a double-wall ECR plasma cavity, a four-step ridge waveguide, an extraction system, and an experimental beam chamber. The mechanical design has been carried out in such a way that both types of experiments, plasma diagnosis and ion implantation, can be easily accommodated simultaneously and separately. To optimize microwave coupling to the ECR plasma cavity, a four-step ridge waveguide is designed. Microwave coupling simulation for the ECR plasma cavity has been performed at different power inputs using COMSOL Multiphysics. An enhanced electric field profile has been obtained at the center of the ECR plasma cavity with the help of a four-step ridge waveguide compared to the WR284 waveguide. The magnetic field distribution for two magnetic rings and the extraction system’s focusing properties have been simulated using the computer simulation technique. A tunable axial magnetic field profile has been obtained with a two permanent magnetic ring arrangement. The dependency of the beam emittance and beam current on accelerating voltages up to 50 kV has been simulated with different ions. It shows that ion masses have a great impact on the beam emittance and output current. This facility has provision for in situ plasma diagnosis using a Langmuir probe and optical emission spectroscopy setups. This system will be used for ion implantation, surface patterning, and studies of basic plasma sciences.


  • Non-invasive beam profile monitor for medical accelerators

    by N. Kumar, A. Salehilashkajani, H.D. Zhang, M. Ady, P. Forck, J. Glutting, O.R. Jones, R. Kersevan, T. Marriott-Doddington, S. Mazzoni, et al.


  • Probing the impact of energetic argon ions on the structural properties of ZnO:Al/TiO2 heterostructures

    by C. P. Saini, A. Barman, N. Kumar, R. Cours, S. Joulie, V. Serin, A. Claverie, A. K. Sinha, D. Kanjilal, A. Kanjilal

    The efficacy of 50 keV Ar+-ion irradiation toward the interfacial and stoichiometric engineering of strained Al-doped ZnO (AZO)/TiO2 heterostructure is systematically investigated using a variety of experimental techniques, notably by cross-sectional transmission electron microscopy. Glancing-angle X-ray diffraction evidences the release of in-plane compressive stress from the as-grown AZO/TiO2 bilayer structure at a critical fluence of 1 × 1016 ions/cm2, and we discuss in the light of microcracks and voids formation combined with the dewetting phenomenon. Ion irradiation also leads to an improvement of stoichiometry in both top AZO and underneath amorphous TiO2 layers, as manifested by depth-dependent energy dispersive X-ray spectroscopy owing to the large diffusion of oxygen toward the AZO/TiO2 interfacial region through the AZO defect sites. Such ion beam induced self-healing in stoichiometry of AZO/TiO2 heterostructure has been attributed to a conjunction of sputtering and diffusion phenomena involving the constituent elements (Zn, Ti, and O). Further increase in ion fluence up to 5 × 1016 ions/cm2 causes a complete deterioration of the heterostructure with the formation of a graded layer via intermixing of these elements, followed by the evolution of voids.